2 Parameters
2.2 List of parameters
SINAMICS DCP
226
List Manual (LH21), 05/2016
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The question is answered:
How often is a connection made to a signal source in the drive object and from which index are these
interconnections saved (r9482 and r9483)?
Dependency:
Refer to: r9481, r9482, r9483, r9485, r9486
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
Refer to: r9481, r9482, r9483, p9484, r9486
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description:
Displays the first index of the signal source being searched for.
Dependency:
Refer to: r9481, r9482, r9483, p9484, r9485
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description:
Displays the number of signal sources from this drive to other drives/drive objects (Binector Output/Connector
Output, BO/CO).
Dependency:
Refer to: r9491, r9492, p9493
Description:
Displays the signal receiver list (Binector Input/Connector Input, BI/CI) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9492, p9493
Notice:
A drive cannot be deleted if this list is not empty!
Otherwise, another drive would continue to attempt to read a signal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
p9484
BICO interconnections search signal source / BICO S_src srch
All objects
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
r9485
BICO interconnections signal source search count / BICO S_src srchQty
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
- -
-
r9486
BICO interconnections signal source search first index / BICO S_src srchIdx
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
- -
-
r9490
Number of BICO interconnections to other drives / Qty BICO to drive
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
- -
-
r9491[0...9]
BI/CI of BICO interconnections to other drives / BI/CI to drive
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...