2 Parameters
2.2 List of parameters
SINAMICS DCP
292
List Manual (LH21), 05/2016
Description:
Display and connector output for the I component of the main current controller.
Description:
Display and connector output for the output of the main current controller precontrol.
Description:
Sets the proportional gain Kp for the main current controller.
Index:
[0] = Current direction positive
[1] = Current direction negative
Description:
Sets the integral time Tn for the main current controller.
Index:
[0] = Current direction positive
[1] = Current direction negative
Description:
Sets rate time Tv for the D elements in the voltage actual value channels of the main current controller precontrol.
Index:
[0] = Side 1
[1] = Side 2
Description:
Sets the lower limit of the voltage actual values for precontrol and adaptation of the main current controller.
r55202
CO: Main current controller I component / Main ctrl I comp
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55210
CO: Main current controller precontrol output / Mn ctr prctr outp
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
- [%]
- [%]
- [%]
p55220[0...1]
Main current controller Kp / Main ctrl Kp
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
0.0001 5.0000
0.2000
p55221[0...1]
Main current controller Tn / Main ctrl Tn
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
0.010 [ms]
1000.000 [ms]
5.000 [ms]
p55222[0...1]
Main current controller precontrol Tv / Mn ctr prctr Tv
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
-1.000 [ms]
1.000 [ms]
0.000 [ms]
p55226
Main current controller voltage lower limit / Main ctr U low lim
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
1.0 [%]
50.0 [%]
10.0 [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...