2 Parameters
2.2 List of parameters
SINAMICS DCP
304
List Manual (LH21), 05/2016
Description:
Displays the actual value for the averaged reactor current of power unit 1.
Dependency:
Refer to: r55530
Description:
Displays the actual value for the averaged reactor current of power unit 2.
Dependency:
Refer to: r55530
Description:
Displays the actual value for the averaged reactor current of power unit 3.
Dependency:
Refer to: r55530
Description:
Display and connector output for the actual power.
Index:
[0] = Power at the output
[1] = Power at side 1
[2] = Power at side 2
[3] = Power at side 1 (with external current measurement)
[4] = Power at side 2 (with external current measurement)
Note:
SINAMICS DCP cannot measure the power.
For index 0:
P = U_out * I_out
The power is calculated from the voltage measured at the output and the calculated output current.
The result is the power that is either issued or fed in at the side with the lower voltage.
For index 1:
P = U1 * I1
The power is calculated from the voltage measured at side 1 and the output current at side 1.
The result is the power that is either issued or fed in at side 1.
For index 2:
P = U2 * I2
The power is calculated from the voltage measured at side 2 and the output current at side 2.
The result is the power that is either issued or fed in at side 2.
For index 3:
P = U1 * I_ext (I_ext = value according to p55156)
The power is calculated from the voltage measured at side 1 and the externally measured current at side 1.
The result is the power that is either issued or fed in at side 1.
r55531
Actual value reactor current power unit 1 averaged / ActVal I_re PU1avg
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
- [A]
- [A]
- [A]
r55532
Actual value reactor current power unit 2 averaged / ActVal I_re PU2avg
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
- [A]
- [A]
- [A]
r55533
Actual value reactor current power unit 3 averaged / ActVal I_re PU3avg
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
- [A]
- [A]
- [A]
r55540[0...4]
CO: Actual power / Act P
DCP_CTRL
Can be changed:
-
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
6850
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...