2 Parameters
2.2 List of parameters
SINAMICS DCP
112
List Manual (LH21), 05/2016
Note:
Re bit 03, 05, 07:
These bits are set if at least one fault/alarm occurs. Data is entered into the fault/alarm buffer with delay. This is the
reason that the fault/alarm buffer should only be read if, after "fault present" or "alarm present" has occurred, a
change in the buffer was also detected (r0944, r9744, r2121).
Re bit 06, 08:
These status bits are used for internal diagnostic purposes only.
Re bit 12, 11:
These status bits are used for the classification of internal alarm classes and are intended for diagnostic purposes
only on certain automation systems with integrated SINAMICS functionality.
Description:
Displays the system runtime in days when the alarm occurred.
Dependency:
Refer to: r2110, r2114, r2122, r2123, r2124, r2125, r2134, r2146, r3121, r3123
Notice:
The time comprises r2145 (days) and r2123 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Displays the system runtime in days when the alarm was cleared.
Dependency:
Refer to: r2110, r2114, r2122, r2123, r2124, r2125, r2134, r2145, r3121, r3123
Notice:
The time comprises r2146 (days) and r2125 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Setting to delete the fault buffer of all existing drive objects.
Value:
0:
Inactive
1:
Start to delete the fault buffer of all drive objects
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136
Note:
p2147 is automatically set to 0 after execution.
Description:
Display and BICO output for the first status word of the monitoring functions.
r2145[0...63]
Alarm time received in days / t_alarm recv days
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
8065
Min Max
Factory
setting
- -
-
r2146[0...63]
Alarm time removed in days / t_alarm res days
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
8065
Min Max
Factory
setting
- -
-
p2147
Delete fault buffer of all drive objects / Del fault buffer
CU_DCP
Can be changed:
U, T
Access level:
4
Data type:
Integer16
Func. diagram:
8060
Min Max
Factory
setting
0 1
0
r2197.3...7
CO/BO: Status word monitoring 1 / ZSW monitor 1
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
2534
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
03
n_act >= 0
Yes
No
8011
07
Speed setp - act val deviation in tolerance
t_off
Yes
No
8011
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...