2 Parameters
2.2 List of parameters
SINAMICS DCP
114
List Manual (LH21), 05/2016
[4] = Fixed value +50 %
[5] = Fixed value +100 %
[6] = Fixed value +150 %
[7] = Fixed value +200 %
[8] = Fixed value -5 %
[9] = Fixed value -10 %
[10] = Fixed value -20 %
[11] = Fixed value -50 %
[12] = Fixed value -100 %
[13] = Fixed value -150 %
[14] = Fixed value -200 %
Dependency:
Refer to: p2900, p2901, p2930
Note:
The signal sources can, for example, be used to interconnect scalings.
Description:
Setting and connector output for a fixed torque value.
Dependency:
Refer to: p2900, p2901, r2902
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can, for example, be used to interconnect a supplementary torque.
Description:
Sets the mode for the time stamp
p3100 = 0: Time stamp, operating hours
p3100 = 1: Time stamp, UTC format
p3100 = 2: Time stamp, operating hours + 01.01.2000
Notice:
The realtime format (p3100 = 1), once selected, remains until the next time that the system is switched off. Switching
back to operating hours (p3100 = 0) or operating hours + 01.01.2000 (p3100=2) is prevented.
Note:
RTC: Real-time clock
UTC: Universal Time Coordinates
The UTC time started, according to the definition on 01.01.1970 at 00:00:00 and is output in days and milliseconds.
Description:
Setting the UTC time.
This means that the drive system is synchronized to the time specified by the time master.
To start p3101[1] must be written to followed by p3101[0]. After writing to p3101[0], the UTC time is accepted.
p3101[0]: Milliseconds
p3101[1]: Days
p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-100000.00 [Nm]
100000.00 [Nm]
0.00 [Nm]
p3100
RTC time stamp mode / RTC t_stamp mode
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 2
2
p3101[0...1]
RTC set UTC time / RTC set UTC
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
0 4294967295
0
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...