SINAMICS DCP
List Manual (LH21), 05/2016
59
2 Parameters
2.2 List of parameters
r0975[4] = 1401 --> 14th of January
r0975[5] = 1 --> PROFIdrive drive object, type class
r0975[6] = 9 --> PROFIdrive drive object sub-type class 1
r0975[7] = 2 --> drive object number = 2
r0975[8] = 0 (reserved)
r0975[9] = 0 (reserved)
r0975[10] = 600 --> second part, firmware version (complete version: V01.02.06.00)
Description:
Resets or downloads all parameters of the drive system.
Value:
0:
Inactive
1:
Start reset of all parameters to factory setting
2:
Start dnload of param. saved in non-volatile mem w/ p0977=1
3:
Start download of volatile parameters from RAM
10:
Start dnload of param. saved in non-volatile mem w/ p0977=10
11:
Start dnload of param. saved in non-volatile mem w/ p0977=11
12:
Start dnload of param. saved in non-volatile mem w/ p0977=12
20:
Start download Siemens internal setting 20
100:
Start resetting of all BICO interconnections
200:
Start deleting all user data
1011: Start dnload of param. saved in volatile mem w/ p0977=1011
1012: Start dnload of param. saved in volatile mem w/ p0977=1012
1013: Start dnload of param. saved in volatile mem w/ p0977=1013
Notice:
After the value has been modified, no further parameter modifications can be made and the status is shown in r3996.
Modifications can be made again when r3996 = 0.
After executing p0976 = 200, the Control Unit is powered on automatically.
Note:
After all of the parameters have been reset to their factory setting, the system must be commissioned for the first time
again.
Resetting or loading is realized in the non-volatile memory.
Procedure:
1. Set p0009 = 30 (parameter reset).
2. Set p0976 to "required value". The system is rebooted.
p0976 is automatically set to 0 after execution.
Description:
Saves all parameters of the drive system to the non-volatile memory.
When saving, only the adjustable parameters intended to be saved are taken into account.
Value:
0:
Inactive
1:
Save in non-volatile memory - downloaded at POWER ON
10:
Save as opt. in non-vol. memory - downloaded w/ p0976=10
11:
Save as opt. in non-vol. memory - downloaded w/ p0976=11
12:
Save as opt. in non-vol. memory - downloaded w/ p0976=12
20:
Save in non-volatile memory as setting 20 (reserved)
80:
Save in non-volatile memory time-optimized (reserved)
1011: Save in volatile memory, downloaded with p0976=1011
1012: Save in volatile memory, downloaded with p0976=1012
1013: Save in volatile memory, downloaded with p0976=1013
Dependency:
Refer to: p0976, r3996
Caution:
Memory card inserted:
The drive parameterization is also saved on the card. Any backed-up data is overwritten!
p0976
Reset and load all parameters / Reset load all par
CU_DCP
Can be changed:
C1(30)
Access level:
1
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 1013
0
p0977
Save all parameters / Save all par
CU_DCP
Can be changed:
U, T
Access level:
1
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 1013
0
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...