SINAMICS DCP
List Manual (LH21), 05/2016
291
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the dynamic voltage limiting on side 1.
Description:
Sets the range of the dynamic voltage limiting on side 1.
Description:
Sets the threshold value for the overvoltage on side 1.
Above this voltage, the power unit pulses are inhibited.
Description:
Sets the signal source for the dynamic voltage limiting on side 2.
Description:
Sets the range of the dynamic voltage limiting on side 2.
Description:
Sets the threshold value for the overvoltage on side 2.
Above this voltage, the power unit pulses are inhibited.
Description:
Display and connector output for the PI output of the main current controller.
p55180
CI: Limiting side 1 U dyn signal source / Lim S1 U dyn s_src
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Func. diagram:
6817
Min Max
Factory
setting
- -
52002[0]
p55181
Limiting side 1 U dyn delta U / Lim S1 U dyn dU
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6817
Min Max
Factory
setting
0.10 [V]
400.00 [V]
10.00 [V]
p55182
Limiting side 1 overvoltage dynamic / Lim S1 U_over dyn
DCP_CTRL
Can be changed:
U, T
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
6817
Min Max
Factory
setting
0 [V]
1500 [V]
1000 [V]
p55185
CI: Limiting side 2 U dyn signal source / Lim S2 U dyn s_src
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Func. diagram:
6817
Min Max
Factory
setting
- -
52002[0]
p55186
Limiting side 2 U dyn delta U / Lim S2 U dyn dU
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6817
Min Max
Factory
setting
0.10 [V]
400.00 [V]
10.00 [V]
p55187
Limiting side 2 overvoltage dynamic / Lim S2 U_over dyn
DCP_CTRL
Can be changed:
U, T
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
6817
Min Max
Factory
setting
0 [V]
1500 [V]
1000 [V]
r55201
CO: Main current controller PI output / Main ctrl PI outp
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6820
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...