SINAMICS DCP
List Manual (LH21), 05/2016
273
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the "undervoltage limited reached" signal of the MPP tracker.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the signal source for the "enable" signal of the MPP tracker.
BI: p54014[0, 1] = 1 signal:
- the MPP tracker is enabled.
BI: p54014[0, 1] = 0 signal:
- the MPP tracker is inhibited.
BI: p54014[2, 3] = 1 signal:
- the MPP tracker is inhibited.
BI: p54014[2, 3] = 0 signal:
- the MPP tracker is enabled.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Display and connector output for the smoothed actual power.
Dependency:
Refer to: p54010, p54011
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Display and connector output for the output of the MPP tracker.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Display and connector output for the output of the MPP tracker after manual/automatic switchover.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
p54013
BI: MPP tracker lower voltage threshold reached signal source / MPPT U_min rch s_s
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
Unsigned32 / Binary
Func. diagram:
6700
Min Max
Factory
setting
- -
55125.11
p54014[0...3]
BI: MPP tracker enable signal source / MPPT enable s_src
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
Unsigned32 / Binary
Func. diagram:
6700
Min Max
Factory
setting
- -
[0]
899.11
[1] 1
[2] 55125.7
[3] 0
r54015
CO: MPP tracker actual power smoothed / MPPT act P smooth
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
- [%]
- [%]
- [%]
r54020
CO: MPP tracker output / MPPT outp
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
- [%]
- [%]
- [%]
r54021
CO: MPP tracker output total / MPPT outp total
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
- [%]
- [%]
- [%]
Summary of Contents for sinamics dcp
Page 2: ......
Page 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Page 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Page 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Page 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Page 517: ...Siemens Parts ...