background image

 

 

SMP181-HLS 

User Guide 

 

 

 

 

 

 

 

 

 

 

 

V1.1-N

DVBCommunity - c

ообщество

 

профессионалов

 

ЦТВ

 

https://dvbcommunity.ru/

Summary of Contents for SMP181-HLS

Page 1: ...SMP181 HLS User Guide V1 1 N DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 2: ... the user CAUTION The CAUTION symbol calls your attention to a situation that if ignored may cause damage to Our product NOTE The NOTE symbol calls your attention to important information TIP The TIP symbol calls your attention to additional information that if followed can make procedures more efficient This guide also contains the following text conventions Black Bold Indicates a button to click...

Page 3: ...1 3 Built in IP Input 8 4 2 CONFIGURING OUTPUT 10 4 2 1 Decoder 10 4 2 2 Built in ASI Output 11 4 2 3 Built in IP Output 11 4 2 4 Configuring Output in Service Configuration 12 4 3 OTHER CONFIGURATIONS 14 4 3 1 Delete Input TS 14 4 3 2 Bypass Input TS 14 4 3 3 Delete a Output TS Program PID 14 4 3 4 Edit TS Info 15 4 3 5 PSI SI 15 PART 5 EQUIPMENT CONFIGURATION 16 5 1 SYSTEM 16 5 2 VERSION INFORMA...

Page 4: ...n the system during periods of lightning Refer all servicing to qualified service personnel Servicing is required when this unit has been damaged in any way Damage Requiring Service Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is damaged If liquid has been spilled or objects have fallen...

Page 5: ... connection are secure to the chassis and that protective covers are in place and secured Never work alone when working in hazardous conditions Always have another person close by in case of an accident Always refer to the manual for safe operation If you have a question about the application or operation contact your provider for assistance Electrostatic Discharge ESD Caution Always wear an ESD p...

Page 6: ... TS IP and decoder status Red or Flashing Red Error Green Normal Flashing Green Initialing or loading a board 2 LCD Screen 3 Up Down Left and Right buttons 4 Menu OK and Esc buttons 1 2 Rear Panel Overview On the back panel of the chassis there three slots available for different boards In SMP181 the HLS TSIP board is in slot1 and the Decoder board is in slot2 Slot 3 is empty 4 1 2 3 DVBCommunity ...

Page 7: ... screws through the front mounting holes and tightening Note the SMP181 chassis is cooled via inbuilt fans Operating temperature is within 0 50 C AC Power Connection Only use the supplied 3 prong power connector or one with equal specifications NEVER tamper with or remove the grounding pin This could cause damage to the equipment personnel or property Make sure the power outlet is switched off bef...

Page 8: ...ly to SMP181 s management port Set the IP address of the laptop computer in the same network with the SMP181 management IP address For example you can set the computer s IP address to 192 168 1 242 Check the physical connection via Command Prompt Try to click the Windows Menu Icon in the corner of the desktop and hit CMD then press Enter you will open the Command Prompt Type ping 192 168 1 241 or ...

Page 9: ...rface We use only IE Firefox and Chrome for testing procedures If you use other browsers like Microsoft Edge you may encounter incomplete UI layouts and configure setting in these browsers may lead to errors 3 1 3 Dropdown Menu On the top of the Web UI you will find a couple of menu items Move the cursor to each item to navigate through the dropdown menus Menu item with a small white arrow on the ...

Page 10: ...ts with modules successfully loaded are visible except the scrambler which is hidden in Output Configuration Area and it is configurable by right clicking the programs in output ports Board 1 in this page refers to the module in slot 1 Board 2 refers to the module in slot 2 and so on Function of the Main Buttons in Service Configuration Refresh Click to refresh input and output configuration or pa...

Page 11: ...one The login session will expire in 5 minutes without any active operation Please click Apply at least once every 5 minutes otherwise your work in the last few minutes might be futile because the login session has stopped without notice Part 4 Input and Output 4 1 Configuring Input 4 1 1 HLS Input Verify the IP input cable is connected to the RJ451 port on the TSIP 02 board Go to Module Configura...

Page 12: ...S1 to Scan TS After the scan the service will be listed under TS1 See the following image we have Service01 in TS1 4 1 2 Built in ASI Input Verify the ASI input cable is connected to ASI In port Go to Status Slot4 ASI Embedded verify the input bitrates are correct See the following image DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 13: ...SIP Embedded Setup Configure network settings for the embedded TSIP board Click Apply before you go to the next step Go to Module Configuration Slot5 TSIP Embedded Input Check the small boxes to open the input channels Choose Protocol enter address and port Click Apply before you go to the next step DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 14: ...o to Status Slot5 TSIP Embedded verify the input bitrate of each IP input channels Go to Service Configuration and Scan TS Refer to ASI input configuration steps DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 15: ...coding channels are available See the following image Some of the items have optional settings Aspect Ratio Conversion Auto 4 3 Letter Box 4 3 Pan and Scan 16 9 Letter Box 16 9 Pan and Scan Output Resolution Fail Mode Still Image Black Screen DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 16: ...t4 ASI Embedded Enter a Constant Rate for the ASI port This Constant Rate shout be at least 2 Mbps higher than the Effective Rate in an ASI Output port Click Apply before you go to the next step Go to Service Configuration Distribute an input TS to the ASI output Port Refer to 4 2 4 4 2 3 Built in IP Output Go to Module Configuration Slot5 TSIP Embedded Output DVBCommunity cообщество профессионало...

Page 17: ...he Decoder Go to Service Configuration right click on the TS1 under Board2 Click Add TS to generate an empty TS in Port1 An empty TS contains 0 service Long click on a service in the input TS and drag it to the Program in the Decoder Port1 TS1 Drop it until a blue arrow appears on the left of the Program Click Apply See the following image There is an input service High Definition Jade in ASI Port...

Page 18: ... s which is called multiplexing Drag a TS to an output port Right click on an existing input TS drag and drop it on an empty output TS See the following image Click Apply A TS cannot be distributed to a Decoder Port in this way You should always generate an empty TS in Decoder in advance DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 19: ... an input port Click Bypass TS to passthrough this TS A bypassed TS and the services in this TS will not be multiplexed SMP181 will not change anything in a TS if you bypass it 4 3 3 Delete a Output TS Program PID Move the cursor to a TS under an output port a red cross will appear after this TS Click the red cross to delete this TS Click Apply DVBCommunity cообщество профессионалов ЦТВ https dvbc...

Page 20: ... TS Info to change service name PID s TS ID and Original Network ID Be careful when you change any PID value to avoid PID conflict within a TS 4 3 5 PSI SI Right click a TS under an output port then click SI Setting to edit NIT BAT and SDT This feature only applies to TS in embedded ASI and TSIP board It does not apply to the TS in Decoder DVBCommunity cообщество профессионалов ЦТВ https dvbcommun...

Page 21: ...on 5 1 System Default Click to restore factory settings SMP181 will reboot by itself after Default process Reboot Click to restart this unit without power off 5 2 Version Information Upgrade DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 22: ... for the unit in a running system Do not disconnect management port or power off a unit during upgrade Otherwise the upgrade might fail and lead to boot failure In a boot failure happened the user may have to return the unit for factory repair 5 3 License License Information is a checklist of licenses Slot 0 refers to the Mainboard Even when a module initialization failure happens due to defective...

Page 23: ...sword is lost you can perform factory setting on the front panel buttons In that case all the configuration will be erased 5 6 Log Log records the operations and activities of the SMP181 We may request an exported log file from user for troubleshooting or other use DVBCommunity cообщество профессионалов ЦТВ https dvbcommunity ru ...

Page 24: ...n be returned for service the client ought to contact our sales representatives and after sales support department by means of email to confirm the need to return the product or part of the product Collect the Serial Numbers to obtain RMA Number Serial Number SN is printed on a label on the chassis and modules To create a RMA number SN must be submitted to support department Once the RMA number ha...

Reviews: