Benefits and Main Features: 

 

 

Very easy to configure 

 

Low cost 

 

Rail mountable 

 

Wide supply input range 

 

Galvanic isolation 

 

Industrial temperature range: 
-40°C / 85°C  (-40°F / 185°F) 

Similiar 
Products 

For other Gateways / Bridges: 

CAN to Modbus 

See also the following links: 

www.adfweb.com?product=HD67011

 

(Modbus RTU Master) 

www.adfweb.com?product=HD67014

 

(Modbus TCP Master) 

www.adfweb.com?product=HD67515

 

(Modbus TCP Slave) 

 

CANopen to Modbus 

See also the following links: 

www.adfweb.com?product=HD67001

 

(Modbus RTU Master) 

www.adfweb.com?product=HD67002

 

(Modbus RTU Slave) 

www.adfweb.com?product=HD67004

 

(Modbus TCP Master) 

www.adfweb.com?product=HD67505

 

(Modbus TCP Slave) 

 

Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

HD67012 

Summary of Contents for HD67012

Page 1: ...perature range 40 C 85 C 40 F 185 F Similiar Products For other Gateways Bridges CAN to Modbus See also the following links www adfweb com product HD67011 Modbus RTU Master www adfweb com product HD67...

Page 2: ...Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to...

Page 3: ...cal interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the insta...

Page 4: ...ModBUS electrical isolation between two BUSes to read CANbus frame from ModBUS word to write CANbus frame from ModBUS word Temperature range 40 C to 85 C To configure the gateway use the available sof...

Page 5: ...ation Modbus Line Open 220 ohm Connector2 CAN H High wire S Shield L Low wire Port RS232 D SUB9 Male PIN2 TX PIN3 RX PIN5 GND Used for A Programmation Port B Modbus on RS232 To connect the device to t...

Page 6: ...software on your PC in order to perform the following Define that the CANbus frame of the CANbus are reading from Modbus Define that the CANbus frame of the CANbus are writing from Modbus USE OF COMP...

Page 7: ...ions of a Programmable CANbus to Modbus Gateway in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtai...

Page 8: ...me that the device attends for the CAN Frame In the field Modbus Register insert the value of Modbus register which contains the number 1 if a CAN frame arrives or the number 0 if it does not arrives...

Page 9: ...Fig 3 the window Receive CAN Frame appears Fig 5 A user who has to read a CANbus frame from CANbus to Modbus needs to insert the coordinates of the CANbus frame in order to be transmitted in the field...

Page 10: ...st Receive COB In the field MODBUS there are the modbus words defined for that COB ID Frame In the field Index MODBUS there is the address that contain the Modbus word In the field Selecet Frame Byte...

Page 11: ...Fig 3 the window Transmit CAN Frame appears Fig 7 A user who has to write a CANbus frame from Modbus to CANbus needs to insert the coordinates of the CANbus frame in order to be transmitted in the fie...

Page 12: ...he list In the field MODBUS there are the Modbus words defined for that COB ID Frame In the field Index MODBUS there is the address that contain the Modbus word In the field Seleceted Frame Byte you s...

Page 13: ...s Slave Document code MN67012_ENG Revision 2 101 Page 13 of 17 UPDATE DEVICE Section Update Device Insert the boot jumper see figure 2 In order to load the parameters after they are set set the Com po...

Page 14: ...RS232 socket to a serial port example one from a personal computer must be made with a Null Modem cable a serial cable where the pins 2 and 3 are crossed It is recommended that the RS232 Cable not ex...

Page 15: ...of 17 MECHANICAL DIMENSIONS Figure 10 Mechanical dimensions scheme ORDER CODE Order Code HD67012 CAN Modbus Slave Converter ACCESSORIES Order Code AC34107 Null Modem Cable Fem Fem DSub 9 Pin 1 5 m Or...

Page 16: ...ean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an appli...

Page 17: ...fweb com Together with the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs b...

Reviews: