Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Rev. 3.00 Sep. 27, 2007 Page 375 of 758
REJ09B0243-0300
Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in Reset-Synchronized PWM Mode:
Figure 9.148 shows an
explanatory diagram of the case where an error occurs in complementary PWM mode and
operation is restarted in reset-synchronized PWM mode after re-setting.
1
RESET
2
TOCR
3
TMDR
(CPWM)
5
PFC
(MTU2)
4
TOER
(1)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(normal)
12
TOER
(0)
13
TOCR
14
TMDR
(RPWM)
15
TOER
(1)
16
PFC
(MTU2)
17
TSTR
(1)
MTU2
module output
TIOC3A
TIOC3B
TIOC3D
Port output
PE9
PE8
PE11
High-Z
High-Z
High-Z
Figure 9.148 Error Occurrence in Complementary PWM Mode,
Recovery in Reset-Synchronized PWM Mode
1 to 10 are the same as in figure 9.144.
11. Set normal mode. (MTU2 output goes low.)
12. Disable channel 3 and 4 output with TOER.
13. Select the reset-synchronized PWM mode output level and cyclic output enabling/disabling
with TOCR.
14. Set reset-synchronized PWM.
15. Enable channel 3 and 4 output with TOER.
16. Set MTU2 output with the PFC.
17. Operation is restarted by TSTR.
Summary of Contents for SH7124 R5F7124
Page 2: ...Rev 3 00 Sep 27 2007 Page ii of xx ...
Page 8: ...Rev 3 00 Sep 27 2007 Page viii of xx ...
Page 36: ...Section 1 Overview Rev 3 00 Sep 27 2007 Page 16 of 758 REJ09B0243 0300 ...
Page 68: ...Section 2 CPU Rev 3 00 Sep 27 2007 Page 48 of 758 REJ09B0243 0300 ...
Page 108: ...Section 5 Exception Handling Rev 3 00 Sep 27 2007 Page 88 of 758 REJ09B0243 0300 ...
Page 166: ...Section 7 User Break Controller UBC Rev 3 00 Sep 27 2007 Page 146 of 758 REJ09B0243 0300 ...
Page 724: ...Section 20 List of Registers Rev 3 00 Sep 27 2007 Page 704 of 758 REJ09B0243 0300 ...
Page 772: ...Rev 3 00 Sep 27 2007 Page 752 of 758 REJ09B0243 0300 ...
Page 778: ...Rev 3 00 Sep 27 2007 Page 758 of 758 REJ09B0243 0300 ...
Page 781: ......