Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Rev. 3.00 Sep. 27, 2007 Page 374 of 758
REJ09B0243-0300
Operation when Error Occurs during Complementary PWM Mode Operation, and
Operation is Restarted in Complementary PWM Mode:
Figure 9.147 shows an explanatory
diagram of the case where an error occurs in complementary PWM mode and operation is
restarted in complementary PWM mode after re-setting (when operation is restarted using
completely new cycle and duty settings).
1
RESET
2
TOCR
3
TMDR
(CPWM)
5
PFC
(MTU2)
4
TOER
(1)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(normal)
12
TOER
(0)
13
TOCR
14
TMDR
(CPWM)
15
TOER
(1)
16
PFC
(MTU2)
17
TSTR
(1)
MTU2
module
output
TIOC3A
TIOC3B
TIOC3D
Port output
PE9
PE8
PE11
High-Z
High-Z
High-Z
Figure 9.147 Error Occurrence in Complementary PWM Mode,
Recovery in Complementary PWM Mode
1 to 10 are the same as in figure 9.144.
11. Set normal mode and make new settings. (MTU2 output goes low.)
12. Disable channel 3 and 4 output with TOER.
13. Select the complementary PWM mode output level and cyclic output enabling/disabling with
TOCR.
14. Set complementary PWM.
15. Enable channel 3 and 4 output with TOER.
16. Set MTU2 output with the PFC.
17. Operation is restarted by TSTR.
Summary of Contents for SH7124 R5F7124
Page 2: ...Rev 3 00 Sep 27 2007 Page ii of xx ...
Page 8: ...Rev 3 00 Sep 27 2007 Page viii of xx ...
Page 36: ...Section 1 Overview Rev 3 00 Sep 27 2007 Page 16 of 758 REJ09B0243 0300 ...
Page 68: ...Section 2 CPU Rev 3 00 Sep 27 2007 Page 48 of 758 REJ09B0243 0300 ...
Page 108: ...Section 5 Exception Handling Rev 3 00 Sep 27 2007 Page 88 of 758 REJ09B0243 0300 ...
Page 166: ...Section 7 User Break Controller UBC Rev 3 00 Sep 27 2007 Page 146 of 758 REJ09B0243 0300 ...
Page 724: ...Section 20 List of Registers Rev 3 00 Sep 27 2007 Page 704 of 758 REJ09B0243 0300 ...
Page 772: ...Rev 3 00 Sep 27 2007 Page 752 of 758 REJ09B0243 0300 ...
Page 778: ...Rev 3 00 Sep 27 2007 Page 758 of 758 REJ09B0243 0300 ...
Page 781: ......