Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Rev. 3.00 Sep. 27, 2007 Page 313 of 758
REJ09B0243-0300
9.4.11
Dead Time Compensation
By measuring the delay of the output waveform and reflecting it to duty, the external pulse width
measurement function can be used as the dead time compensation function while the
complementary PWM is in operation.
Tdead
Tdelay
Upper arm signal
Lower arm signal
Inverter output detection signal
Dead time delay signal
Figure 9.79 Delay in Dead Time in Complementary PWM Operation