Section 9 Multi-Function Timer Pulse Unit 2 (MTU2)
Rev. 3.00 Sep. 27, 2007 Page 290 of 758
REJ09B0243-0300
13. Counter Clearing by Another Channel
In complementary PWM mode, by setting a mode for synchronization with another channel by
means of the timer synchronous register (TSYR), and selecting synchronous clearing with bits
CCLR2 to CCLR0 in the timer control register (TCR), it is possible to have TCNT_3,
TCNT_4, and TCNTS cleared by another channel.
Figure 9.55 illustrates the operation.
Use of this function enables counter clearing and restarting to be performed by means of an
external signal.
TGRA_3
TCDR
TDDR
H'0000
Channel 1
Input capture A
TCNT_1
TCNT_3
TCNT_4
TCNTS
Synchronous counter clearing by channel 1 input capture A
Figure 9.55 Counter Clearing Synchronized with Another Channel