background image

 

OPTICAL SYSTEMS DESIGN 

 

DOC ID: 10120001 

OSD2524 OPERATOR MANUAL

 

 
 

PAGE 175  

STATION CLOCK CONFIGURATION 

 

The Synce module may have a Station clock input and/or a Station clock output. 
 

Clock input frequency

 

If supported by the Synce HW, the station clock input frequency can be configured, the possible 
frequencies are: 
1,544 MHz, 2,048 MHz or 10 MHz 
 

Clock Output frequency

 

If supported by the Synce HW, the station clock output frequency can be configured, the possible 
frequencies are: 
1,544 MHz, 2,048 MHz or 10 MHz 
 

SYNCE PORTS 

 

For each possible port on switch. 
 

Port

 

The port number to configure. 
 

SSM Enable

 

Enable and disable of SSM functionality on this port. 
 

Tx SSM

 

Monitoring of the transmitted SSM QL on this port. Transmitted QL should be the Quality Level of the 
clock generated by this node. This means the QL of the clock source this node is locked to 
 

Rx SSM

 

Monitoring of the received SSM QL on this port. If link is down on port, QL_LINK is indicated. If no 
SSM is received, QL_FAIL is indicated 
 

1000BaseT Mode

 

If PHY is in 1000BaseT Mode then this is monitoring the master/slave mode. In order to receive clock on 
a port, it has to be in slave mode. In order to transmit clock on a port, it has to be in master mode 

 

 

Buttons 
 

: Click to save changes. 

: Click to undo any changes made locally and revert to previously saved values. 

 

: Refreshes the displayed table starting from the input fields. 

 

 

Summary of Contents for OSD2524

Page 1: ...User Manual OSD2524 MANAGED 20 x 10 100 1000BASE T RJ45 4 x COMBO RJ45 SFP 2 x 1G SFP ETHERNET SWITCH...

Page 2: ......

Page 3: ...L SPECIFICATIONS 20 4 2 INSTALLATION 21 4 3 OSD2524 DIMENSIONS 22 5 OSD2524 FRONT AND REAR PANELS 23 5 1 FRONT PANEL 23 5 2 REAR PANEL 23 6 POWER SUPPLY CONNECTIONS 24 7 LED INDICATORS 25 8 FITTING SF...

Page 4: ...ROTECTION 128 SPANNING TREE 131 IPMC PROFILE CONFIGURATIONS 139 MVR CONFIGURATIONS 143 IPMC 146 NAVIGATING THE IGMP SNOOPING VLAN TABLE 150 IGMP SNOOPING VLAN TABLE COLUMNS 150 NAVIGATING THE MLD SNOO...

Page 5: ...VLAN S CONFIGURATION 243 REMOTE MIRRORING PORT CONFIGURATION 243 CONFIGURATION GUIDELINE FOR ALL FEATURES 244 UPNP CONFIGURATION 246 PTP EXPERNAL CLOCK MODE 247 PTP EXTERNAL CLOCK CONFIGURATION 247 PT...

Page 6: ...RCE GUARD TABLE COLUMNS 315 RADIUS SERVERS 317 RADIUS AUTHENTICATION STATISTICS 319 RADIUS ACCOUNTING STATISTICS 322 AGGREGATION 334 AGGREGATION GROUP STATUS 334 LOOP PROTECTION STATUS 340 SPANNING TR...

Page 7: ...393 IMAGE INFORMATION 394 CONFIGURATION 395 10 WARRANTY 400 10 1 WARRANTY PERIOD 400 10 2 REPAIRS 400 WARRANTY REPAIRS 400 OUT OF WARRANTY REPAIRS 400 SITE REPAIRS 400 EXCLUSIONS 400 FIGURE 1 FRONT PA...

Page 8: ...le for one fiber operation A major benefit of the OSD2524 is its reliable and consistent performance over the 25 C to 70 C temperature range 2 FUNCTIONAL DESCRIPTION Managed L2 switch for small to med...

Page 9: ...Link down power savings Scales power based on cable length Thermal protection Management HTTP server Web management CLI console port Management access filtering System log Software download through we...

Page 10: ...PANELS FIGURE 1 FRONT PANEL 1 Board Status LED 2 USB Console Port 3 View LED Mode Button 4 View Mode LEDs Indicators 5 Port Status LEDs 6 RJ45 Copper Ports 7 SFP Fiber Ports 8 SFP LEDs 9 Reset Button...

Page 11: ...the unit The OSD2524 DC version requires external 10 to 36VDC 40VA Max power FIGURE 3 DC POWER CONNECTION TABLE 1 DC POWER CONNECTION External Power Pin Specification Pin 1 Pin 3 0V Ground Isolated Pi...

Page 12: ...de button cycles the Copper Port Status LED indication Speed Mode Duplex Mode Status Mode Reserved Copper Port Status LED The Copper Port Status LED will indicate different information Speed Mode Gree...

Page 13: ...and insert into appropriate SFP port Gently push the SFP until it locks into place Remove plastic rubber dust cap and fit appropriate fiber cable Removing SFP Remove fiber connector Pull the SFP leve...

Page 14: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 14...

Page 15: ...ICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 15 3 6 CLI OVERVIEW CONNECT TO CLI The Silicon Laboratories CP210x VCP Drivers have to be installed on the PC before connecting the swi...

Page 16: ...ould jump to the next line 4 Using the Username and password to login the switch Default Username admin Default Password None CLI COMMAND FOR IP CONFIGURATION show ip interface brief Display the curre...

Page 17: ...r enter the URL 192 168 0 99 Enter the username and password IP CONFIGURATION In the treemap on the left expand the Configuration System IP E nter the IPv4 address and Mask Length in the table Choose...

Page 18: ...01 OSD2524 OPERATOR MANUAL PAGE 18 USERS AUTHENTICATION In the tree map on the left expand the Configuration Security Switch Users Click admin to change the current admin account setting If multiple u...

Page 19: ...iguration changes must be saved otherwise all the changes will be lost after rebooting SAVE CONFIGURATION TO START UP In the treemap below expand the Maintenance and expand Configuration then select S...

Page 20: ...ck pressure and IEEE802 3x full duplex flow control Optical Optical Port Connectors SFP SFP Options Short haul long haul single fiber operation etc Please consult OSD datasheet 102100009 or contact OS...

Page 21: ...service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures during servicing of equipment Areas where laser products are ins...

Page 22: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 22 4 3 OSD2524 DIMENSIONS FIGURE 7 OSD2524 MAIN DIMENSIONS...

Page 23: ...ard Status LED 2 USB Console Port 3 View LED Mode Button 4 View Mode LEDs Indicators 5 Port Status LEDs 6 RJ45 Copper Ports 7 SFP Fiber Ports 8 SFP LEDs 9 Reset Button 5 2 REAR PANEL FIGURE 9 OSD2524D...

Page 24: ...C Inlet DUAL REDUNDANT AC POWERED 90 264VAC 50VA Max IEC Inlet DUAL REDUNDANT DC POWERED 10 to 36VDC 50VA Max 4 way terminal block FUSE AC VERSIONS ONLY 1A 250V Anti Surge 5x20mm Connect the dual redu...

Page 25: ...e button cycles the Copper Port Status LED indication Speed Mode Duplex Mode Status Mode Reserved Copper Port Status LED The Copper Port Status LED will indicate different information Speed Mode Green...

Page 26: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 26...

Page 27: ...talling Ensure that the SFP is fully engaged and latched into position Inserting SFP Ensure that the SFP lever is in the locked position and insert into appropriate SFP port Gently push the SFP until...

Page 28: ...tch port and power the unit Open a web browser window Firefox IEx etc Enter the IP address of the switch on the web browser The default IP address assigned to the OSD2524 is 192 168 0 99 A login windo...

Page 29: ...ollows Menu can be expanded to show sub menus by clicking the heading Menu is expanded and sub menus are displayed Clicking the heading will close the submenu Menu title Clicking will open the GUI win...

Page 30: ...from 32 to 126 System Name An administratively assigned name for this managed node By convention this is the node s fully qualified domain name A domain name is a text string drawn from the alphabet...

Page 31: ...between interfaces will not be routed In Router mode traffic is routed between all interfaces DNS Server This setting controls the DNS name resolution done by the switch There are four servers availa...

Page 32: ...is enabled system will relay DNS requests to the currently configured DNS server and reply as a DNS resolver to the client devices on the network Only IPv4 DNS proxy is now supported IP Interfaces Del...

Page 33: ...6 client is enabled DHCPv6 Current Lease For DHCPv6 interface with an active lease this column shows the interface address provided by the DHCPv6 server IPv6 Address The IPv6 address of the interface...

Page 34: ...y 128 for IPv6 routes Only a default route will have a mask length of 0 as it will match anything Gateway The IP address of the IP gateway Valid format is dotted decimal notation or a valid IPv6 notat...

Page 35: ...fields of up to four hexadecimal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax that can be used as a shorthand way of representing multi...

Page 36: ...Lists various Time Zones world wide Select appropriate Time Zone from the drop down and click Save to set Acronym User can set the acronym of the time zone This is a User configurable acronym to iden...

Page 37: ...ber Day Select the starting day Month Select the starting month Hours Select the starting hour Minutes Select the starting minute End time settings Week Select the ending week number Day Select the en...

Page 38: ...ANUAL PAGE 38 Offset Enter the number of minutes to add during Daylight Saving Time Range 1 to 1440 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved...

Page 39: ...re Enabled Enable server mode operation Disabled Disable server mode operation Server Address Indicates the IPv4 host address of syslog server If the switch provide DNS feature it also can be a domain...

Page 40: ...mperature sensor the highest temperature is used for controlling the fan Max Temperature The temperature at which the fan will be to set to run at full speed The value accepted is within the range of...

Page 41: ...in a block 1 high for SFPs 2 high for RJ45s to the left of the ports A pushbutton and a 4 high tower of LEDs is placed next to the front ethernet port LEDs The pushbutton selects between four differen...

Page 42: ...sity 100 Full power 0 LED off MAINTENANCE On time at link change When a network administrator does maintenance of the switch e g adding or moving users he might want to have full LED intensity during...

Page 43: ...ion EEE works by powering down circuits when there is no traffic When a port gets data to be transmitted all circuits are powered up The time it takes to power up the circuits is named wakeup time The...

Page 44: ...g traffic will give some latency in the traffic The switch can be set to optimize EEE for either best power saving or least traffic latency PORT CONFIGURATION Port The switch port number of the logica...

Page 45: ...eue When an urgent queue gets data to be transmitted the circuits will be powered up at once and the latency will be reduced to the wakeup time EEE Urgent Queues Queues set will activate transmission...

Page 46: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 46 THERMAL PROTECTION CONFIGURATION Configuration Thermal Protection...

Page 47: ...rotection is used to protect the chip from getting overheated When the temperature exceeds the configured thermal protection temperature ports will be turned off in order to decrease the power consump...

Page 48: ...with the corresponding group will be turned off Temperatures between 0 and 255 C are supported Port groups The group the port belongs to 4 groups are supported Buttons Click to save changes Click to u...

Page 49: ...s the highest speed that is compatible with the link partner 10Mbps HDX Forces the cu port in 10Mbps half duplex mode 10Mbps FDX Forces the cu port in 10Mbps full duplex mode 100Mbps HDX Forces the cu...

Page 50: ...ntrol capabilities will always be shown as disabled PFC When PFC 802 1Qbb Priority Flow Control is enabled on a port then flow control on a priority level is enabled Through the Priority field range o...

Page 51: ...SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 51 Click to undo any changes made locally and revert to previously saved values Click to refresh the page Any changes made locally will be...

Page 52: ...DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 52 DHCP SERVER DHCP Server Mode Configuration Configuration DHCP Server Mode This page configures global mode and VLAN mode to enable disable DHCP server p...

Page 53: ...LAN ID then you can just input it into either one of the first and second VLAN ID or both On the other hand if you want to disable existed VLAN range then you can follow the steps 1 Press to add a new...

Page 54: ...EXCLUDED IP ADDRESS Configure excluded IP addresses IP Range Define the IP range to be excluded IP addresses The first excluded IP must be smaller than or equal to the second excluded IP BUT if the IP...

Page 55: ...o into the configuration page Name Configure the pool name that accepts all printable characters except white space If you want to configure the detail settings you can click the pool name to go into...

Page 56: ...0120001 OSD2524 OPERATOR MANUAL PAGE 56 Buttons Click to add a new DHCP pool Click to save changes Click to undo any changes made locally and revert to previously saved values DHCP SNOOPING CONFIGURAT...

Page 57: ...CP request messages will be forwarded to trusted ports and only allow reply packets from trusted ports Disabled Disable DHCP snooping mode operation Port Mode Configuration Indicates the DHCP snooping...

Page 58: ...Mode Indicates the DHCP relay mode operation Possible modes are Enabled Enable DHCP relay mode operation When DHCP relay mode operation is enabled the agent forwards and transfers DHCP messages betwee...

Page 59: ...on mode is enabled Disabled Disable DHCP relay information mode operation Relay Information Policy Indicates the DHCP relay information option policy When DHCP relay information mode operation is enab...

Page 60: ...login as another user on the web server is to close and reopen the browser The displayed values for each user are User Name The name identifying the user This is also a link to Add Edit User Privileg...

Page 61: ...ult setting most groups privilege level 5 has the read only access and privilege level 10 has the read write access And the system maintenance software upload factory defaults and etc need user privil...

Page 62: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 62 Privilege Level Configuration Configuration Security Switch Privilege Levels...

Page 63: ...an overview of the privilege levels Group Name The name identifying the privilege group In most cases a privilege level group consists of a single module e g LACP RSTP or QoS but a few of them contain...

Page 64: ...tatistics read only status statistics read write e g for clearing of statistics User Privilege should be same or greater than the authorization Privilege level to have the access to that group Notes t...

Page 65: ...is not possible Local Use the local user database on the switch for authentication Radius Use remote RADIUS server s for authentication Tacacs Use remote TACACS server s for authentication Methods tha...

Page 66: ...CLI commands according to his privilege level Cmd Lvl Authorize all commands with a privilege level higher than or equal to this level Valid values are in the range 0 to 15 Cfg Cmd Also authorize conf...

Page 67: ...TEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 67 Click to save changes Click to undo any changes made locally and revert to previously saved values SSH Configuration Configuration Security...

Page 68: ...age Mode Indicates the SSH mode operation Possible modes are Enabled Enable SSH mode operation Disabled Disable SSH mode operation Buttons Click to save changes Click to undo any changes made locally...

Page 69: ...ificate maintenance Possible operations are None No operation Delete Delete the current certificate Upload Upload a certificate PEM file Possible methods are Web Browser or URL Generate Generate a new...

Page 70: ...that only contains is not allowed Certificate Status Display the current status of certificate on the switch Possible statuses are Switch secure HTTP certificate is presented Switch secure HTTP certi...

Page 71: ...cates the VLAN ID for the access management entry Start IP address Indicates the start IP address for the access management entry End IP address Indicates the end IP address for the access management...

Page 72: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 72 Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 73: ...MP System Configure SNMP on this page Mode Indicates the SNMP mode operation Possible modes are Enabled Enable SNMP mode operation Disabled Disable SNMP mode operation Version Indicates the SNMP suppo...

Page 74: ...rite access string to permit access to SNMP agent The allowed string length is 0 to 255 and the allowed content is the ASCII characters from 33 to 126 The field is applicable only when SNMP version is...

Page 75: ...mode operation TRAP DESTINATION CONFIGURATIONS Configure trap destinations on this page Name Indicates the trap Configuration s name Indicates the trap destination s name Enable Indicates the trap de...

Page 76: ...Pv6 address is in 128 bit records represented as eight fields of up to four hexadecimal digits with a colon separating each field For example fe80 215 c5ff fe03 4dc7 The symbol is a special syntax tha...

Page 77: ...lowed string length is 1 to 32 and the allowed content is ASCII characters from 33 to 126 The community string will be treated as security name and map a SNMPv1 or SNMPv2c community string Source IP I...

Page 78: ...er words if user engine ID equal system engine ID then it is local user otherwise it s remote user User Name A string identifying the user name that this entry should belong to The allowed string leng...

Page 79: ...ol that this entry should belong to Possible privacy protocols are None No privacy protocol DES An optional flag to indicate that this user uses DES authentication protocol AES An optional flag to ind...

Page 80: ...ity models are v1 Reserved for SNMPv1 v2c Reserved for SNMPv2c usm User based Security Model USM Security Name A string identifying the security name that this entry should belong to The allowed strin...

Page 81: ...this entry should belong to Possible view types are included An optional flag to indicate that this view subtree should be included excluded An optional flag to indicate that this view subtree should...

Page 82: ...t this entry should belong to Possible view types are included An optional flag to indicate that this view subtree should be included excluded An optional flag to indicate that this view subtree shoul...

Page 83: ...ete the entry It will be deleted during the next save ID Indicates the index of the entry The range is from 1 to 65535 Data Source Indicates the port ID which wants to be monitored If in stacking swit...

Page 84: ...tacking switch the value must add 1000000 switch ID 1 for example if the port is switch 3 port 5 the value is 2000005 Interval Indicates the interval in seconds for sampling the history statistics dat...

Page 85: ...are discarded even the packets are normal InErrors The number of inbound packets that contained errors preventing them from being deliverable to a higher layer protocol InUnknownProtos the number of t...

Page 86: ...ess than the falling threshold RisingOrFallingTrigger alarm when the first value is larger than the rising threshold or less than the falling threshold default Rising Threshold Rising threshold value...

Page 87: ...event the possible types are none No SNMP log is created no SNMP trap is sent log Create SNMP log entry when the event is triggered snmptrap Send SNMP trap when the event is triggered logandtrap Creat...

Page 88: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 88 Port Security Limit Control Configuration Configuration Security Network Limit Control...

Page 89: ...g period of all modules that use the functionality The Aging Period can be set to a number between 10 and 10 000 000 seconds To understand why aging may be desired consider the following scenario Supp...

Page 90: ...ch 2 Disable and re enable Limit Control on the port or the switch 3 Click the Reopen button Trap Shutdown If Limit 1 MAC addresses is seen on the port both the Trap and the Shutdown actions described...

Page 91: ...llowed access to the network These backend RADIUS servers are configured on the Configuration Security AAA page The IEEE802 1X standard defines port based operation but non standard variants overcome...

Page 92: ...st Identity EAPOL frames Valid values are in the range 1 to 65535 seconds This has no effect for MAC based ports Aging Period This setting applies to the following modes i e modes using the Port Secur...

Page 93: ...tch Incoming traffic will be classified to and switched on the RADIUS assigned VLAN The RADIUS server must be configured to transmit special RADIUS attributes to take advantage of this feature see RAD...

Page 94: ...esponses between the supplicant and the authentication server Frames sent between the supplicant and the switch are special 802 1X frames known as EAPOL EAP Over LANs frames EAPOL frames encapsulate E...

Page 95: ...pplicants attached to the port to reply to requests sent from the switch Instead the switch uses the supplicant s MAC address which is obtained from the first EAPOL Start or EAPOL Response Identity fr...

Page 96: ...cessfully authenticated If present and valid the port s Port VLAN ID will be changed to this VLAN ID the port will be set to be a member of that VLAN ID and the port will be forced into VLAN unaware m...

Page 97: ...POL Success frame when entering the Guest VLAN While in the Guest VLAN the switch monitors the link for EAPOL frames and if one such frame is received the switch immediately takes the port out of the...

Page 98: ...24 OPERATOR MANUAL PAGE 98 Click to save changes Click to undo any changes made locally and revert to previously saved values Click to refresh the page Any changes made locally will be undone ACL Conf...

Page 99: ...Port Configuration Configuration Security Network ACL Ports Configure the ACL parameters ACE of each switch port These parameters will affect frames received on a port unless the frame matches a spec...

Page 100: ...ved on the port are mirrored Disabled Frames received on the port are not mirrored The default value is Disabled Logging Specify the logging operation of this port Notice that the logging message does...

Page 101: ...ons Click to save changes Click to undo any changes made locally and revert to previously saved values Click to refresh the page Any changes made locally will be undone Click to clear the counters ACL...

Page 102: ...ame row and its range is 1 to 16 Rate The valid rate is 0 3276700 in pps or 0 100 200 300 1000000 in kbps Unit Specify the rate unit The allowed values are pps packets per second kbps Kbits per second...

Page 103: ...e type of the ACE Possible values are Any The ACE will match any frame type EType The ACE will match Ethernet Type frames Note that an Ethernet Type based ACE will not get matched by IP and ARP frames...

Page 104: ...ceived on the port are not mirrored The default value is Disabled Counter The counter indicates the number of times the ACE was hit by a frame Modification Buttons You can modify each ACE Access Contr...

Page 105: ...20001 OSD2524 OPERATOR MANUAL PAGE 105 Configuration Security Network IP Source Guard IP Source Guard Configuration Configuration Security Network IP Source Guard Configuration This page provides IP S...

Page 106: ...and Port Mode on a given port are enabled IP Source Guard is enabled on this given port Max Dynamic Clients Specify the maximum number of dynamic clients that can be learned on given port This value c...

Page 107: ...tch Delete Check to delete the entry It will be deleted during the next save Port The logical port for the settings VLAN ID The vlan id for the settings IP Address Allowed Source IP address MAC addres...

Page 108: ...L SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 108 Configuration Security Network ARP Inspection ARP Inspection Configuration Configuration Security Network ARP Inspection Port Configur...

Page 109: ...are Enabled Enable ARP Inspection operation Disabled Disable ARP Inspection operation If you want to inspect the VLAN configuration you have to enable the setting of Check VLAN The default setting of...

Page 110: ...to the port setting There are four log types and possible types are None Log nothing Deny Log denied entries Permit Log permitted entries ALL Log all entries Buttons Click to save changes Click to un...

Page 111: ...le Clicking the button will update the displayed table starting from that or the closest next VLAN Table match The will use the next entry of the currently displayed VLAN entry as a basis for the next...

Page 112: ...10120001 OSD2524 OPERATOR MANUAL PAGE 112 Click to add a new entry to the Static IP Source Guard table Click to save changes Click to undo any changes made locally and revert to previously saved value...

Page 113: ...te the entry It will be deleted during the next save Port The logical port for the settings VLAN ID The vlan id for the settings MAC Address Allowed Source MAC address in ARP request packets IP Addres...

Page 114: ...mic ARP Inspection Table The Start from port address VLAN MAC address and IP address input fields allow the user to select the starting point in the Dynamic ARP Inspection Table Clicking the button wi...

Page 115: ...refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Click to save changes Click to undo any changes made locally and r...

Page 116: ...onfiguration Configuration Security AAA RADIUS This page allows you to configure the RADIUS servers GLOBAL CONFIGURATION These setting are common for all of the RADIUS servers Timeout Timeout is the n...

Page 117: ...ce is used NAS IPv6 Address Attribute 95 The IPv6 address to be used as attribute 95 in RADIUS Access Request packets If this field is left blank the IP address of the outgoing interface is used NAS I...

Page 118: ...able and the RADIUS server can be configured as needed Up to 5 servers are supported The delete button can be used to undo the addition of the new server Buttons Click to add a new RADIUS server Click...

Page 119: ...ew requests to a server that has failed to respond to a previous request This will stop the switch from continually trying to contact a server that it has already determined as dead Setting the Deadti...

Page 120: ...l setting overrides the global key Leaving it blank will use the global key ADDING A NEW SERVER Click to add a new TACACS server An empty row is added to the table and the TACACS server can be configu...

Page 121: ...the frame Check to enable the use of the Source MAC address or uncheck to disable By default Source MAC Address is enabled Destination MAC Address The Destination MAC Address can be used to calculate...

Page 122: ...same row Group ID Normal indicates there is no aggregation Only one group ID is valid per port Port Members Each switch port is listed for each group ID Select a radio button to include a port in an...

Page 123: ...connected to the same partner Key The Key value incurred by the port range 1 65535 The Auto setting will set the key as appropriate by the physical link speed 10Mb 1 100Mb 2 1Gb 3 Using the Specific s...

Page 124: ...before sending a LACP packet Prio The Prio controls the priority of the port range 1 65535 If the LACP partner wants to form a larger group than is supported by this device then this parameter will c...

Page 125: ...network and quickly determine the location of failing links or fault conditions OAM Mode Configures the OAM Mode as Active or Passive The default mode is Passive ACTIVE MODE DTE s configured in Activ...

Page 126: ...rt will allow the DTE to execute the remote loopback command that helps in the fault detection Link Monitor Support Controls whether the Link Monitor support is enabled for the switch port On enabling...

Page 127: ...rs as detected at the Media Access Control sublayer Error Window for Error Frame Event must be an integer value between 1 60 and its default value is 1 Whereas Error Threshold must be between 0 429496...

Page 128: ...mes that had transmission errors as detected at the Media Access Control sublayer Error Window for Seconds Summary Event must be an integer value between 10 900 and its default value is 60 Whereas Err...

Page 129: ...MANUAL PAGE 129 Configuration Loop Protection This page allows the user to inspect the current Loop Protection configurations and possibly change them as well General Settings Enable Loop Protection...

Page 130: ...A value of zero will keep a port disabled until next device restart Default value is 180 seconds Port Configuration Port The switch port number of the port Enable Controls whether loop protection is e...

Page 131: ...RIDGE CONFIGURATION Configuration Spanning Tree Bridge Settings This page allows you to configure STP system settings The settings are used by all STP Bridge instances in the Switch Basic Settings Pro...

Page 132: ...is defines the initial value of remaining Hops for MSTI information generated at the boundary of an MSTI region It defines how many bridges a root bridge can distribute its BPDU information to Valid v...

Page 133: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 133 Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 134: ...urrent STP MSTI bridge instance priority configurations and possibly change them as well Configuration Identification Configuration Name The name identifying the VLAN to MSTI mapping Bridges must shar...

Page 135: ...will receive the VLANs not explicitly mapped VLANs Mapped The list of VLANs mapped to the MSTI The VLANs can be given as a single xx xx being between 1 and 4094 VLAN or a range xx yy each of which mus...

Page 136: ...ions and possibly change them as well MSTI The bridge instance The CIST is the default instance which is always active Priority Controls the bridge priority Lower numeric values have better priority T...

Page 137: ...of the logical STP port STP Enabled Controls whether STP is enabled on this switch port Path Cost Controls the path cost incurred by the port The Auto setting will set the path cost as appropriate by...

Page 138: ...ion of the network influence the spanning tree active topology possibly because those bridges are not under the full control of the administrator This feature is also known as Root Guard Restricted TC...

Page 139: ...physical and aggregated ports Port The switch port number of the corresponding STP CIST and MSTI port Path Cost Controls the path cost incurred by the port The Auto setting will set the path cost as...

Page 140: ...ate at maximum 64 Profiles with at maximum 128 corresponding rules for each Global Profile Mode Enable Disable the Global IPMC Profile System starts to do filtering based on profile settings only when...

Page 141: ...ck the edit button to enter the rule setting page of the designated profile Summary about the designated profile will be shown by clicking the view button You can manage or inspect the rules of the de...

Page 142: ...e at maximum 128 address entries in the system Delete Check to delete the entry The designated entry will be deleted during the next save Entry Name The name used for indexing the address entry table...

Page 143: ...esses Click Save Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the displayed table starting from the input fields Updates the table start...

Page 144: ...pplication a PC or a network television or a set top box can receive the multicast stream Multiple set top boxes or PCs can be connected to one subscriber port which is a switch port configured as an...

Page 145: ...MVR VLAN entries or it can be added to the new entries IGMP Address Define the IPv4 address as source address used in IP header for IGMP control frames The default IGMP address is not set 0 0 0 0 Whe...

Page 146: ...active The designated port does not participate MVR operations Source Configure uplink ports that receive and send multicast data as source ports Subscribers cannot be directly connected to source por...

Page 147: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 147 IGMP SNOOPING Basic Configuration Configuration IPMC IGMP Snooping Basic Configuration...

Page 148: ...guration Snooping Enabled Enable the Global IGMP Snooping Unregistered IPMCv4 Flooding Enabled Enable unregistered IPMCv4 traffic flooding The flooding control takes effect only when IGMP Snooping is...

Page 149: ...ide Proxy Enabled Enable IGMP Proxy This feature can be used to avoid forwarding unnecessary join and leave messages to the router side Router Port Specify which ports act as router ports A router por...

Page 150: ...displayed entry as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table Use the button to start over IGMP SNOOPING VLAN TABLE COLUMNS Delete Che...

Page 151: ...The allowed range is 1 to 31744 seconds default query interval is 125 seconds QRI Query Response Interval The Maximum Response Delay used to calculate the Maximum Response Code inserted into the peri...

Page 152: ...hanges made locally and revert to previously saved values Refreshes the displayed table starting from the input fields Updates the table starting from the first entry in the IPMC Profile Address Confi...

Page 153: ...Profile Select the IPMC Profile as the filtering condition for the specific port Summary about the designated profile will be shown by clicking the view button Profile Management Button You can inspec...

Page 154: ...ATOR MANUAL PAGE 154 MLD SNOOPING MLD Snooping Configuration Configuration IPMC MLD Snooping Basic Configuration This page provides MLD Snooping related configuration Snooping Enabled Enable the Globa...

Page 155: ...Enable MLD Leave Proxy This feature can be used to avoid forwarding unnecessary leave messages to the router side Proxy Enabled Enable MLD Proxy This feature can be used to avoid forwarding unnecessa...

Page 156: ...t closest VLAN Table match The will use the last entry of the currently displayed entry as a basis for the next lookup When the end is reached the text No more entries is shown in the displayed table...

Page 157: ...0 seconds LLQI Last Listener Query Interval The Last Listener Query Interval is the Maximum Response Delay used to calculate the Maximum Response Code inserted into Multicast Address Specific Queries...

Page 158: ...DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 158 Updates the table starting from the first entry in the IPMC Profile Address Configuration Updates the table starting with the entry after the last ent...

Page 159: ...rofile Select the IPMC Profile as the filtering condition for the specific port Summary about the designated profile will be shown by clicking the view button Profile Management Button You can inspect...

Page 160: ...DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 160 LLDP LLDP CONFIGURATION Configuration LLDP This page allows the user to inspect and configure the current LLDP interface settings LLDP PARAMETE...

Page 161: ...ion from neighbor units is analyzed Tx only The switch will drop LLDP information received from neighbors but will send out LLDP information Disabled The switch will not send out LLDP information and...

Page 162: ...TLV When checked the system name is included in LLDP information transmitted Sys Descr Optional TLV When checked the system description is included in LLDP information transmitted Sys Capa Optional T...

Page 163: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 163 This page allows you to configure the LLDP MED This function applies to VoIP devices which support LLDP MED...

Page 164: ...P MED information as fast as possible to new neighbors Because there is a risk of an LLDP frame being lost during transmission between neighbors it is recommended to repeat the fast start transmission...

Page 165: ...he vertical datum specified Floors Representing altitude in a form more relevant in buildings which have different floor to floor dimensions An altitude 0 0 is meaningful even outside a building and r...

Page 166: ...imitation Country code The two letter ISO 3166 country code in capital ASCII letters Example AU DE or US State National subdivisions state region province prefecture County County parish gun Japan dis...

Page 167: ...nal code Additional code Example 1320300003 EMERGENCY CALL SERVICE Emergency Call Service e g 000 911 and others such as defined by TIA or NENA Emergency Call Service Emergency Call Service ELIN ident...

Page 168: ...sed are 1 Voice 2 Guest Voice 3 Softphone Voice 4 Video Conferencing 5 Streaming Video 6 Control Signalling conditionally support a separate network policy for the media types above A large network ma...

Page 169: ...d are typically configured to use an untagged VLAN or a single tagged data specific VLAN When a network policy is defined for use with an untagged VLAN see Tagged flag below then the L2 priority field...

Page 170: ...represents use of the default DSCP value as defined in RFC 2475 Adding a new policy Click to add a new policy Specify the Application type Tag VLAN ID L2 Priority and DSCP for the new policy Click Sav...

Page 171: ...YSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 171 SYNCE CONFIGURATION NOTE To use this function the unit must be fitted with the optional OSD2524SE Synchronous Ethernet module Configurati...

Page 172: ...selecting Manual Mode Nominated When a clock source is nominated the clock output from the related PHY Port is enabled against the clock controller This makes it available as a possible source in the...

Page 173: ...k source if the loss of clock condition is cleared within this time ANEG Mode This is relevant for 1000BaseT ports only In order to recover clock from port it must be negotiated to Slave mode In order...

Page 174: ...he ZL30xxx based Synce modules support both EEC1 and EEC2 option The difference is EEC1 DPLL bandwidth 3 5 Hz EEC2 DPLL bandwidth 0 1 Hz State This is indicating the state of the clock selector Possib...

Page 175: ...M Enable Enable and disable of SSM functionality on this port Tx SSM Monitoring of the transmitted SSM QL on this port Transmitted QL should be the Quality Level of the clock generated by this node Th...

Page 176: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 176 ETHERNET PROTECTION SWITCHING Configuration EPS The Ethernet Linear Protection Switch instances are configured here...

Page 177: ...re Port This will create a 1 1 EPS Port This will create a 1 1 EPS W Flow The working flow for the EPS See Domain P Flow The protecting flow for the EPS See Domain W SF MEP The working Signal Fail rep...

Page 178: ...OC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 178 MAINTENANCE ENTITY POINT Configuration MEP The Maintenance Entity Point instances are configured here Delete This box is used to mark a MEP for deletion...

Page 179: ...nd traffic on Residence Port Up This is a Up MEP monitoring egress OAM and traffic on Residence Port Residence Port The port where MEP is monitoring see Direction For a EVC MEP the port must be a port...

Page 180: ...the displayed table starting from the input fields ETHERNET RING PROTECTION SWITCHING Configuration ERPS The ERPS instances are configured here Delete This box is used to mark an ERPS for deletion in...

Page 181: ...ted sub ring without virtual channel it is configured as 0 for such ring instances 0 in this field indicates that no Port 1 APS MEP is associated with this instance Ring Type Type of Protecting ring I...

Page 182: ...DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 182 Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the displayed table starting from t...

Page 183: ...on this page Set timeouts for entries in the dynamic MAC Table and configure the static MAC table here AGING CONFIGURATION By default dynamic entries are removed from the MAC table after 300 seconds...

Page 184: ...managing the switch is added to the Static Mac Table before changing to secure learning mode otherwise the management link is lost and can only be restored by using another non secure port or by conn...

Page 185: ...24 OPERATOR MANUAL PAGE 185 Buttons Click to add a new entry to the static MAC table Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the di...

Page 186: ...s in other modes are members of the VLANs specified in the Allowed VLANs field By default only VLAN 1 is enabled More VLANs may be created by using a list syntax where the individual elements are sepa...

Page 187: ...s Trunk ports have the following characteristics By default a trunk port is member of all VLANs 1 4095 The VLANs that a trunk port is member of may be limited by the use of Allowed VLANs Frames classi...

Page 188: ...ow frames without this TPID are dropped Notice If the S port is configured to accept Tagged and Untagged frames see Ingress Acceptance below frames with a C tag are treated like frames with an S tag I...

Page 189: ...ging of frames on egress Untag Port VLAN Frames classified to the Port VLAN are transmitted untagged Other frames are transmitted with the relevant tag Tag All All frames whether classified to the Por...

Page 190: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 190 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values VLAN TRANSLATION...

Page 191: ...e switch Ports to use a given VLAN Translation Mapping Group This will enable all VLAN Translation mappings of that group if any on the selected switch port The displayed settings are Port The Port co...

Page 192: ...configured to use any of the groups but only one at any given time Multiple ports can be configured to use the same group A valid Group ID is an integer value from 1 to 14 Note By default each port is...

Page 193: ...r value from 1 to 14 Note By default each port is set to use the group with Group ID equal to the port number For example port 1 is by default set to use group with GID 1 VID Indicates the VLAN of the...

Page 194: ...ne VLAN but it can be a member of multiple Private VLANs Delete To delete a private VLAN entry check this box The entry will be deleted during the next save Private VLAN ID Indicates the ID of this pa...

Page 195: ...tons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to add a new entry to the static MAC table Click to save changes Click to undo any cha...

Page 196: ...s A check box is provided for each port of a private VLAN When checked port isolation is enabled on that port When unchecked port isolation is disabled on that port By default port isolation is disabl...

Page 197: ...the mapping VLAN ID Indicates the VLAN ID the above MAC will be mapped to Port Members A row of check boxes for each port is displayed for each MAC to VLAN ID mapping entry To include a port in the m...

Page 198: ...used to undo the addition of new mappings The maximum possible MAC to VLAN ID mapping entries are limited to 256 Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh...

Page 199: ...n the option selected from the preceding Frame Type selection menu Below are the criteria for the three different Frame Types 1 Ethernet Value in the text field when Ethernet is selected as a Frame Ty...

Page 200: ...cial characters and underscores _ are not allowed Adding a New Group to VLAN mapping entry Click to add a new entry in the mapping table An empty row is added to the table where Frame Type Value and t...

Page 201: ...otocols inside that Group Furthermore the Group to VLAN ID mapping is not unique as long as the port lists of these mappings are mutually exclusive e g Group1 can be mapped to VID 1 on port 1 and to V...

Page 202: ...the page automatically Automatic refresh occurs every 3 seconds Click to save changes Click to undo any changes made locally and revert to previously saved values Refreshes the displayed table starti...

Page 203: ...ubnet to VLAN ID is a unique matching Port Members A row of check boxes for each port is displayed for each IP subnet to VLAN ID mapping entry To include a port in a mapping simply check the box To re...

Page 204: ...204 Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to save changes Click to undo any changes made locally and revert to previously saved...

Page 205: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 205 VOICE VLAN CONFIGURATION VOICE VLAN CONFIGURATION Configuration Voice VLAN Configuration...

Page 206: ...ode is enabled In other cases it will be based on hardware aging time The actual aging time will be situated between the age_time 2 age_time interval Traffic Class Indicates the Voice VLAN traffic cla...

Page 207: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 207 Click to save changes Click to undo any changes made locally and revert to previously saved values VOICE VLAN OUI TABLE...

Page 208: ...uring the next save Telephony OUI A telephony OUI address is a globally unique identifier assigned to a vendor by IEEE It must be 6 characters long and the input format is xx xx xx x is a hexadecimal...

Page 209: ...MANUAL PAGE 209 ETHERNET SERVICES PORT CONFIGURATION Configuration Ethernet Services Ports This page displays current EVC port configurations The settings can also be configured here Port The logical...

Page 210: ...sed on the outer or inner tag This can be used on NNI ports connected to another service provider where an outer tunnel tag is added together with the inner tag identifying the EVC The allowed values...

Page 211: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 211 L2CP PORT CONFIGURATION Configuration Ethernet Services L2CP...

Page 212: ...and GARP 01 80 C2 00 00 2X MAC addresses for the settings contained in the same row L2CP Mode The L2CP mode for the specific port The possible values are Peer Allow to peer L2CP frames Forward Allow t...

Page 213: ...ports The settings can also be configured here Start Policer ID The start Policer ID for displaying the table entries The allowed range is from 1 through 256 Number of Entries The number of entries p...

Page 214: ...owed range is from 0 through 10000000 kilobit per second CBS The Committed Burst Size of the bandwidth profile The allowed range is from 0 through 100000 bytes EIR The Excess Information Rate for MEF...

Page 215: ...ssible values are Enabled Learning is enabled MAC addresses are learned Disabled Learning is disabled MAC addresses are not learned Inner Tag Type The inner tag type is used to determine whether an in...

Page 216: ...Tag DEI The inner tag DEI value The allowed value is 0 or 1 Outer Tag VID The EVC outer tag VID for UNI ports The allowed range is from 0 through 4095 NNI Ports The list of Network to Network Interfa...

Page 217: ...match untagged frames only C Tagged The ECE will match custom tagged frames only S Tagged The ECE will match service tagged frames only Tagged The ECE will match tagged frames only VID The VLAN ID for...

Page 218: ...oes not map to an EVC Tag Pop Count The ingress tag pop count for the ECE The possible range is from 0 through 2 Policy ID The ACL Policy ID for the ECE The range is from 0 through 255 Class The traff...

Page 219: ...a new ECE before the current row Edits the ECE row Moves the ECE up the list Moves the ECE down the list Deletes the ECE The lowest plus sign adds a new entry at the bottom of the ECE listings Auto r...

Page 220: ...1 OSD2524 OPERATOR MANUAL PAGE 220 QOS QOS INGRESS PORT CLASSIFICATION Configuration QoS Port Classification This page allows you to configure the basic QoS Ingress Classification settings for all swi...

Page 221: ...nce level If the port is VLAN aware the frame is tagged and Tag Class is enabled then the frame is classified to a DPL that is mapped from the PCP and DEI value in the tag Otherwise the frame is class...

Page 222: ...SCP Based Click to Enable DSCP Based QoS Ingress Port Classification Address Mode The IP MAC address mode specifying whether the QCL classification must be based on source SMAC SIP or destination DMAC...

Page 223: ...nable or disable the port policer for this switch port Rate Controls the rate for the port policer This value is restricted to 100 3276700 when Unit is kbps or fps and 1 3276 when Unit is Mbps or kfps...

Page 224: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 224 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 225: ...IGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 225 QOS INGRESS QUEUE POLICERS Configuration QoS Queue Policing Buttons Click to save changes Click to undo any changes made locally and revert to prev...

Page 226: ...ler This page provides an overview of QoS Egress Port Schedulers for all switch ports The displayed settings are Port The logical port for the settings contained in the same row Click on the port numb...

Page 227: ...des an overview of QoS Egress Port Shapers for all switch ports The displayed settings are Port The logical port for the settings contained in the same row Click on the port number in order to configu...

Page 228: ...Egress Port Tag Remarking for all switch ports The displayed settings are Port The logical port for the settings contained in the same row Click on the port number in order to configure tag remarking...

Page 229: ...r all switch ports The displayed settings are Port The Port column shows the list of ports for which you can configure dscp ingress and egress settings Ingress In Ingress settings you can change ingre...

Page 230: ...f Disable No Egress rewrite Enable Rewrite enabled without remapping Remap DP Unaware DSCP from analyzer is remapped and frame is remarked with remapped DSCP value The remapped DSCP value is always ta...

Page 231: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 231 DSCP BASED QOS INGRESS CLASSIFICATION Configuration QoS DSCP Based QoS...

Page 232: ...of supported DSCP values are 64 Trust Controls whether a specific DSCP value is trusted Only frames with trusted DSCP values are mapped to a specific QoS class and Drop Precedence Level Frames with un...

Page 233: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 233 DSCP TRANSLATION Configuration QoS DSCP Translation...

Page 234: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 234...

Page 235: ...L SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 235 This page allows you to configure the basic QoS DSCP Translation settings for all switches DSCP translation can be done in Ingress or...

Page 236: ...lated to any of 0 63 DSCP values 2 Classify Click to enable Classification at Ingress side Egress There are the following configurable parameters for Egress side 1 Remap DP0 Controls the remapping for...

Page 237: ...oS class and Drop Precedence Level to DSCP value The displayed settings are QoS Class Actual QoS class DSCP DP0 Select the classified DSCP value 0 63 for Drop Precedence Level 0 DSCP DP1 Select the cl...

Page 238: ...Any Match any DMAC Unicast Match unicast DMAC Multicast Match multicast DMAC Broadcast Match broadcast DMAC The default value is Any SMAC Match specific source MAC address or Any If a port is configur...

Page 239: ...rameters configured are matched with the frame s content Possible actions are CoS Classify Class of Service DPL Classify Drop Precedence Level DSCP Classify DSCP value PCP Classify PCP value DEI Class...

Page 240: ...able The displayed settings are Frame Type The frame type for which the configuration below applies Enable Enable or disable the global storm policer for the given frame type Rate Controls the rate fo...

Page 241: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 241 MIRRORING AND REMOTE MIRRORING CONFIGURATION Configuration Mirroring...

Page 242: ...d mirrored traffic you have to set VLAN egress tagging as Untag ALL on the reflector port SESSION Select session id to configure MODE To Enabled Disabled the mirror or Remote Mirroring function TYPE S...

Page 243: ...sources but not both REMOTE MIRRORING PORT CONFIGURATION The following table is used for port role selecting Port The logical port for the settings contained in the same row Source Select mirror mode...

Page 244: ...gh disabled disabled dhcp_snooping High disabled disabled ip_source_guard Critical disabled disabled disabled ipmc igmpsnp Critical un conflict ipmc mldsnp Critical un conflict lacp Low o disabled lld...

Page 245: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 245 Buttons Click to save changes Click to undo any changes made locally and revert to previously saved values...

Page 246: ...tion The duration carried in SSDP packets is used to inform a control point or control points how often it or they should receive an SSDP advertisement message from this switch If a control point does...

Page 247: ...in out put External Enable This Selection box will allow you to configure the External Clock output The following values are possible 1 True Enable the external clock output 2 False Disable the exter...

Page 248: ...Master Only clock s Device Type is Master Only 5 Slave Only clock s Device Type is Slave Only Profile Indicates the profile used by the clock Port List Set check mark for each port configured for this...

Page 249: ...and Sync messages from See Unicast Slave Configuration VID VLAN Identifier used for tagging the PTP frames Note Packets are tagged if the port is configured for vlan tagging for the configured VID PC...

Page 250: ...ssing the Save button GVRP protocol timers Join time is a value in the range of 1 20cs i e in units of one hundredth of a second The default value is 20cs Leave time is a value in the range of 60 300c...

Page 251: ...iguration can be performed either before or after GVRP is configured globally the protocol operation will be the same Port The logical port that is to be configured Mode Mode can be either Disabled or...

Page 252: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 252 SFLOW CONFIGURATION Configuration sFlow...

Page 253: ...0001 OSD2524 OPERATOR MANUAL PAGE 253 This page allows for configuring sFlow The configuration is divided into two parts Configuration of the sFlow receiver a k a sFlow collector and configuration of...

Page 254: ...configured through SNMP all controls except for the Release button are disabled to avoid inadvertent reconfiguration The button allows for releasing the current owner and disable sFlow sampling The bu...

Page 255: ...Flow Sampler Max Header The maximum number of bytes that should be copied from a sampled packet to the sFlow datagram Valid range is 14 to 200 bytes with default being 128 bytes If the maximum datagr...

Page 256: ...es the UDLD mode on a port Valid values are Disable Normal and Aggressive Default mode is Disable Disable In disabled mode UDLD functionality doesn t exists on port Normal In normal mode if the link s...

Page 257: ...s that are in the advertisement phase and are determined to be bidirectional The range is from 7 to 90 seconds Default value is 7 seconds Currently default time interval is supported due to lack of de...

Page 258: ...ation is provided here Contact The system contact configured in Configuration System Information System Contact Name The system name configured in Configuration System Information System Name Location...

Page 259: ...g server running on the switch if any System Uptime The period of time the device has been operational Software Version The software version of this switch Software Date The date when the switch softw...

Page 260: ...last 120 samples are graphed and the last numbers are displayed as text as well In order to display the SVG graph your browser must support the SVG format Consult the SVG Wiki for more information on...

Page 261: ...isplays the status of the IP protocol layer The status is defined by the IP interfaces the IP routes and the neighbour cache ARP cache status IP Interfaces Interface The name of the interface Type The...

Page 262: ...of this route Gateway The gateway address of this route Status The status flags of the route Neighbour cache IP Address The IP address of the entry Link Address The Link MAC address for which a bindi...

Page 263: ...ify which system log entries will be cleared To clear specific system log entries select the clear level first then click the button The Start from ID input field allow the user to change the starting...

Page 264: ...vel Time The occurred time of the system log entry Message The detail message of the system log entry Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs eve...

Page 265: ...f the system log entry ID The ID 1 of the system log entry Message The detailed message of the system log entry Buttons Updates the system log entry to the current entry ID Updates the system log entr...

Page 266: ...he current status for EEE Local Port This is the logical port number for this row Link Shows if the link is up for the port green link up red link down EEE cap Shows if the port is EEE capable EEE Ena...

Page 267: ...down if no frame has been received or transmitted in 5 uSec Actiphy Savings Shows if the system is currently saving power due to ActiPhy PerfectReach Savings Shows if the system is currently saving po...

Page 268: ...ated to the fan control FAN STATUS Fan Speed Shows the speed that the fan is currently running at in RPM Rounds Per Minute Temperature Sensor Shows the temperature of the temperature sensor s in Celsi...

Page 269: ...on related to thermal protection Port The switch port number Temperature Shows the current chip temperature in degrees Celsius Port Status Shows if the port is thermally protected link is down or if t...

Page 270: ...s State This page provides an overview of the current switch port states The port states are illustrated as follows RJ45 ports SFP ports State Disabled Down Link Buttons Auto refresh Check this box to...

Page 271: ...for the settings contained in the same row Description The description of the port Packets The number of received and transmitted packets per port Bytes The number of received and transmitted bytes pe...

Page 272: ...ING COUNTERS Monitor Ports QoS Statistics This page provides statistics for the different queues for all switch ports The displayed counters are Port The logical port for the settings contained in the...

Page 273: ...ns The maximum number of QCEs is 256 on each switch User Indicates the QCL user QCE Indicates the QCE id Port Indicates the list of ports configured with the QCE Frame Type Indicates the type of frame...

Page 274: ...le in that case it shows conflict status as Yes otherwise it is always No Please note that conflict can be resolved by releasing the H W resources required to add QCL entry on pressing Resolve Conflic...

Page 275: ...for receive and transmit the size counters for receive and transmit and the error counters for receive and transmit RECEIVE TOTAL AND TRANSMIT TOTAL Rx and Tx Packets The number of received and trans...

Page 276: ...r input and output queue RECEIVE ERROR COUNTERS Rx Drops The number of frames dropped due to lack of receive buffers or egress congestion Rx CRC Alignment The number of frames received with CRC or ali...

Page 277: ...xc Coll The number of frames dropped due to excessive or late collisions Buttons The port select box determines which port is affected by clicking the buttons Auto refresh Check this box to refresh th...

Page 278: ...e management system RECEIVE TOTAL AND TRANSMIT TOTAL Rx and Tx OAM Information PDU s The number of received and transmitted OAM Information PDU s Discontinuities of this counter can occur at re initia...

Page 279: ...d Tx Variable Request A count of the number of Variable Request OAMPDUs received and transmitted on this interface Rx and Tx Variable Response A count of the number of Variable Response OAMPDUs receiv...

Page 280: ...status of this configuration is retrieved from the PHY Remote Loopback Support If status is enabled DTE is capable of OAM remote loopback mode Link Monitoring Support If status is enabled DTE supports...

Page 281: ...OAM client may use this field to decide if it needs to be processed an Information TLV that is identical to the previous Information TLV doesn t need to be parsed as nothing in it has changed PDU Perm...

Page 282: ...e displays the status for the Peer for the respective port Port The switch port number Sequence Number This two octet field indicates the total number of events occurred at the remote end Frame Error...

Page 283: ...Event Threshold This four octet field indicates the number of errored frames in the period is required to be equal to or greater than in order for the event to be generated Frame Period Errors This f...

Page 284: ...s required to be equal to or greater than in order for the event to be generated encoded as a 16 bit unsigned integer Event Seconds Summary Events This two octet field indicates the number of errored...

Page 285: ...OC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 285 DHCP DHCP SERVER DHCP Server Statistics Monitor DHCP Server Statistics This page displays the database counters and the number of DHCP messages sent and...

Page 286: ...istrator assigns an IP address to a client That is the pool is of host type Expired Binding Number of bindings that their lease time expired or they are cleared from Automatic Manual type bindings DHC...

Page 287: ...ent ACK Number of DHCP ACK messages sent NAK Number of DHCP NAK messages sent Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to cl...

Page 288: ...s generated for DHCP clients BINDING IP ADDRESS Display all bindings IP IP address allocated to DHCP client Type Type of binding Possible types are Automatic Manual Expired State State of binding Poss...

Page 289: ...fresh the page immediately Click to clear selected bindings If the selected binding is Automatic or Manual then it is changed to be Expired If the selected binding is expired then it is freed Click to...

Page 290: ...ver Binding This page displays declined IP addresses DECLINED IP ADDRESSES Display IP addresses declined by DHCP clients Declined IP List of IP addresses declined Buttons Auto refresh Check this box t...

Page 291: ...es per page input field When first visited the web page will show the first 20 entries from the beginning of the Dynamic DHCP snooping Table The MAC address and VLAN input fields allows the user to se...

Page 292: ...ntry IP Subnet Mask User IP subnet mask of the entry DHCP Server Address DHCP Server address of the entry Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs...

Page 293: ...ackets received from server Receive Missing Agent Option The number of packets received without agent information options Receive Missing Circuit ID The number of packets received with the Circuit ID...

Page 294: ...agent information option Replace Agent Option The number of packets which were replaced with relay agent information option Keep Agent Option The number of packets whose relay agent information was r...

Page 295: ...forwarding mechanism And clear the statistics on specific port may not take effect on global statistics since it gathers the different layer overview RECEIVE AND TRANSMIT PACKETS Rx and Tx Discover T...

Page 296: ...gned The number of lease unassigned option 53 with value 11 packets received and transmitted Rx and Tx Lease Unknown The number of lease unknown option 53 with value 12 packets received and transmitte...

Page 297: ...gement Interface The interface type through which the remote host can access the switch Received Packets Number of received packets from the interface when access management mode is enabled Allowed Pa...

Page 298: ...GE 298 Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Clear all statistics NETWORK Port Security Port Secu...

Page 299: ...ule which in turn asks all user modules whether to allow this new MAC address to forward or block it For a MAC address to be set in the forwarding state all enabled user modules must unanimously agree...

Page 300: ...user module and is awaiting frames from unknown MAC addresses to arrive Limit Reached The Port Security service is enabled by at least the Limit Control user module and that module has indicated that...

Page 301: ...p for software based learning In this mode frames from unknown MAC addresses are passed on to the port security module which in turn asks all user modules whether to allow this new MAC address to forw...

Page 302: ...allow this MAC address to forward and aging is enabled the Port Security module will periodically check that this MAC address still forwards traffic If the age period measured in seconds expires and n...

Page 303: ...the most recently received frame from a new client for MAC based authentication Last ID The user name supplicant identity carried in the most recently received Response Identity EAPOL frame for EAPOL...

Page 304: ...OSD2524 OPERATOR MANUAL PAGE 304 Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately NAS Statistics Po...

Page 305: ...ot overridden by NAS If the VLAN ID is assigned by the RADIUS server RADIUS assigned is appended to the VLAN ID Read more about RADIUS assigned VLANs here If the port is moved to the Guest VLAN Guest...

Page 306: ...n transmitted by the switch Tx Request ID dot1xAuthEapolReqIdFramesTx The number of EAPOL Request Identity frames that have been transmitted by the switch Tx Requests dot1xAuthEapolReqFramesTx The num...

Page 307: ...ication Indicates that the supplicant client has successfully authenticated to the backend server Rx Auth Failures dot1xAuthBackendAuthFails 802 1X and MAC based Counts the number of times that the sw...

Page 308: ...upplicant identity carried in the most recently received Response Identity EAPOL frame MAC based Not applicable SELECTED COUNTERS Selected Counters The Selected Counters table is visible when the port...

Page 309: ...the other reason the client will remain in the unauthenticated state for Hold Time seconds Last Authentication Shows the date and time of the last authentication of the client successful as well as u...

Page 310: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 310 ACL Status Monitor Security Network ACL Status...

Page 311: ...ACE will match IPv4 frames with ICMP protocol IPv4 UDP The ACE will match IPv4 frames with UDP protocol IPv4 TCP The ACE will match IPv4 frames with TCP protocol IPv4 Other The ACE will match IPv4 fra...

Page 312: ...ect box determines which ACL user is affected by clicking the buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page i...

Page 313: ...ess VLAN MAC address and IP address input fields allow the user to select the starting point in the Dynamic ARP Inspection Table Clicking the button will update the displayed table starting from that...

Page 314: ...atic refresh occurs every 3 seconds Click to refresh the page immediately Flushes all dynamic entries Updates the table starting from the first entry in the Dynamic ARP Inspection Table Updates the ta...

Page 315: ...t fields allow the user to select the starting point in the Dynamic IP Source Guard Table Clicking the button will update the displayed table starting from that or the closest next Dynamic IP Source G...

Page 316: ...resh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Flushes all dynamic entries Updates the table starting from the first entry in the Dynamic AR...

Page 317: ...e made to this server but it did not reply within the configured timeout The server has temporarily been disabled but will get re enabled when the dead time expires The number of seconds left before t...

Page 318: ...ATOR MANUAL PAGE 318 Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately RADIUS Authentication Statisti...

Page 319: ...UTHENTICATION STATISTICS The statistics map closely to those specified in RFC4668 RADIUS Authentication Client MIB Use the server select box to switch between the backend servers to show details for P...

Page 320: ...icator attributes or unknown types are not included as malformed access responses Rx Bad Authenticators radiusAuthClientExtBadAuthenticators The number of RADIUS Access Response packets containing inv...

Page 321: ...s information about the state of the server and the latest round trip time Name RFC4668 Name Description IP Address IP address and UDP port for the authentication server in question State Shows the st...

Page 322: ...s with an invalid length Bad authenticators or unknown types are not included as malformed access responses Rx Bad Authenticators radiusAcctClientExtBadAuthenticators The number of RADIUS packets cont...

Page 323: ...and running Ready The server is enabled IP communication is up and running and the RADIUS module is ready to accept accounting attempts Dead X seconds left Accounting attempts were made to this server...

Page 324: ...STEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 324 Click to refresh the page immediately Clears the counters for the selected server The Pending Requests counter will not be cleared by this...

Page 325: ...lowest ID found in the Statistics table The Start from Control Index allows the user to select the starting point in the Statistics table Clicking the button will update the displayed table starting f...

Page 326: ...Under size The total number of packets received that were less than 64 octets Over size The total number of packets received that were longer than 1518 octets Frag The number of frames which size is l...

Page 327: ...588 octets in length Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Updates the table starting fro...

Page 328: ...the next closest History table match The will use the last entry of the currently displayed entry as a basis for the next lookup When the end is reached the text No more entries is shown in the displ...

Page 329: ...that were longer than 1518 octets Frag The number of frames which size is less than 64 octets received with invalid CRC Jabb The number of frames which size is larger than 64 octets received with inva...

Page 330: ...e displayed table starting from that or the next closest Alarm table match The will use the last entry of the currently displayed entry as a basis for the next lookup When the end is reached the text...

Page 331: ...Index Falling event index Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Updates the table startin...

Page 332: ...Index found in the Event table The Start from Event Index and Log Index allows the user to select the starting point in the Event table Clicking the button will update the displayed table starting fr...

Page 333: ...x to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page immediately Updates the table starting from the first entry in the Event Table i e the entry with...

Page 334: ...associated with this aggregation instance Name Name of the Aggregation group ID Type Type of the Aggregation group Static or LACP Speed Speed of the Aggregation group Configured ports Configured membe...

Page 335: ...id is shown as isid aggr id and for GLAGs as aggr id Partner System ID The system ID MAC address of the aggregation partner Partner Key The Key that the partner has assigned to this aggregation ID La...

Page 336: ...o means that LACP is not enabled or that the port link is down Backup means that the port could not join the aggregation group but will join if other port leaves Meanwhile it s LACP status is disabled...

Page 337: ...OC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 337 The partner s port priority Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refr...

Page 338: ...switch port number LACP Received Shows how many LACP frames have been received at each port LACP Transmitted Shows how many LACP frames have been sent from each port Discarded Shows how many unknown o...

Page 339: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 339...

Page 340: ...port Action The currently configured port action Transmit The currently configured port transmit mode Loops The number of loops detected on this port Status The current loop protection status of the...

Page 341: ...nce This is also a link to the STP Detailed Bridge Status Bridge ID The Bridge ID of this Bridge instance Root ID The Bridge ID of the currently elected root bridge Root Port The switch port currently...

Page 342: ...STEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 342 Buttons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Click to refresh the page i...

Page 343: ...s Port The switch port number of the logical STP port CIST Role The current STP port role of the CIST port The port role can be one of the following values AlternatePort BackupPort RootPort Designated...

Page 344: ...The number of MSTP BPDU s received transmitted on the port RSTP The number of RSTP BPDU s received transmitted on the port STP The number of legacy STP Configuration BPDU s received transmitted on th...

Page 345: ...pectively IGMP MLD Queries Transmitted The number of Transmitted Queries for IGMP and MLD respectively IGMPv1 Joins Received The number of Received IGMPv1 Join s IGMPv2 MLDv1 Report s Received The num...

Page 346: ...hen first visited the web page will show the first 20 entries from the beginning of the MVR Channels Groups Information Table The Start from VLAN and Group Address input fields allow the user to selec...

Page 347: ...ons Auto refresh Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Updates the table starting from...

Page 348: ...page input field When first visited the web page will show the first 20 entries from the beginning of the MVR SFM Information Table The Start from VLAN and Group Address input fields allow the user to...

Page 349: ...address the text None is shown in the Source Address field Type Indicates the Type It can be either Allow or Deny Hardware Filter Switch Indicates whether data plane destined to the specific group ad...

Page 350: ...YSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 350 IPMC IGMP SNOOPING IGMP Snooping Status Monitor IPMC IGMP Snooping Status This page provides IGMP Snooping status VLAN ID The VLAN ID of...

Page 351: ...The number of Received V3 Reports V2 Leaves Received The number of Received V2 Leaves Router Port Display which ports act as router ports A router port is a port on the Ethernet switch that leads tow...

Page 352: ...f the IGMP Group Table The Start from VLAN and group input fields allow the user to select the starting point in the IGMP Group Table Clicking the button will update the displayed table starting from...

Page 353: ...Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Updates the table starting from the first entry...

Page 354: ...t field When first visited the web page will show the first 20 entries from the beginning of the IGMP SFM Information Table The Start from VLAN and group input fields allow the user to select the star...

Page 355: ...text None is shown in the Source Address field Type Indicates the Type It can be either Allow or Deny Hardware Filter Switch Indicates whether data plane destined to the specific group address from t...

Page 356: ...VLAN ID The VLAN ID of the entry Querier Version Working Querier Version currently Host Version Working Host Version currently Querier Status Shows the Querier status is ACTIVE or IDLE DISABLE denote...

Page 357: ...towards the Layer 3 multicast device or MLD querier Static denotes the specific port is configured to be a router port Dynamic denotes the specific port is learnt to be a router port Both denote the s...

Page 358: ...le The Start from VLAN and group input fields allow the user to select the starting point in the MLD Group Table Clicking the button will update the displayed table starting from that or the closest n...

Page 359: ...this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the displayed table starting from the input fields Updates the table starting from the first entry in the...

Page 360: ...first visited the web page will show the first 20 entries from the beginning of the MLD SFM Information Table The Start from VLAN and group input fields allow the user to select the starting point in...

Page 361: ...None is shown in the Source Address field Type Indicates the Type It can be either Allow or Deny Hardware Filter Switch Indicates whether data plane destined to the specific group address from the sou...

Page 362: ...Interface The interface on which the LLDP frame was received Chassis ID The Chassis ID is the identification of the neighbor s LLDP frames Port ID The Port ID is the identification of the neighbor por...

Page 363: ...apability is disabled the capability is followed by Management Address Management Address is the neighbor unit s address that is used for higher layer entities to assist discovery by the network manag...

Page 364: ...h Router 2 IEEE 802 1 Bridge 3 IEEE 802 3 Repeater included for historical reasons 4 IEEE 802 11 Wireless Access Point 5 Any device that supports the IEEE 802 1AB and MED extensions defined by TIA 105...

Page 365: ...Discovery services defined in this class include media type specific network layer policy discovery LLDP MED Communication Endpoint Class III The LLDP MED Communication Endpoint Class III definition...

Page 366: ...tribution and other similar applications supporting streaming video services that require specific network policy treatment Video applications relying on TCP with buffering would not be an intended us...

Page 367: ...identifies if MAC PHY auto negotiation is supported by the link partner Auto negotiation status Auto negotiation status identifies if auto negotiation is currently enabled at the link partner If Auto...

Page 368: ...E is not enabled on particular interface then it displays as EEE not enabled for this interface If the link partner doesn t supports EEE then it displays as Link partner is not EEE capable The columns...

Page 369: ...k partners request was based on stale information Echo Rx Tw The link partner s Echo Rx Tw value Resolved Tx Tw The resolved Tx Tw for this link Note NOT the link partner The resolved value that is th...

Page 370: ...ounters If checked the global counters are cleared when is pressed Neighbor entries were last changed Shows the time when the last entry was last deleted or added It also shows the time elapsed since...

Page 371: ...re removed from the table when a given interface s link is down an LLDP shutdown frame is received or when the entry ages out TLVs Discarded Each LLDP frame can contain multiple pieces of information...

Page 372: ...ters for UNI ports of ECEs mapping to the EVC And the MPLS Pseudo Wires counters are included when the PW ID is attached to the selected EVC Class The traffic class for the EVC Rx Green The number of...

Page 373: ...mber of discarded in the yellow color Buttons The port select box determines which port is affected by clicking the buttons Auto refresh Check this box to refresh the page automatically Automatic refr...

Page 374: ...lock in out put External Enable Shows the current External clock output configuration 1 True Enable the external clock output 2 False Disable the external clock output Adjust Method Shows the current...

Page 375: ...particular Clock Instance 0 3 Device Type Indicates the Type of the Clock Instance There are five Device Types 1 Ord Bound Clock s Device Type is Ordinary Boundary Clock 2 P2p Transp Clock s Device T...

Page 376: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 376 MAC TABLE Monitor MAC Table...

Page 377: ...next MAC Table match In addition the two input fields will upon a button click assume the value of the first displayed entry allowing for continuous refresh with the same start address The will use t...

Page 378: ...ually configured in hardware VLAN ID VLAN ID for which the Port members are displayed Port Members A row of check boxes for each port is displayed for each VLAN ID If a port is included in a VLAN the...

Page 379: ...e last entry of the currently displayed VLAN entry as a basis for the next lookup When the end is reached the text No data exists for the selected user is shown in the table Use the button to start ov...

Page 380: ...iguration and basically reflects what is actually configured in hardware If a given software modules hasn t overridden any of the port settings the text No data exists for the selected user is shown i...

Page 381: ...licts Two users may have conflicting requirements to a port s configuration For instance one user may require all frames to be tagged on egress while another requires all frames to be untagged on egre...

Page 382: ...FLOW STATISTICS Monitor sFlow This page shows receiver and per port sFlow statistics RECEIVER STATISTICS Owner This field shows the current owner of the sFlow configuration It assumes one of three val...

Page 383: ...ource of errors is invalid sFlow receiver IP hostname configuration To diagnose paste the receiver s IP address hostname into the Ping Web page Diagnostics Ping Ping6 Flow Samples The total number of...

Page 384: ...ts UDLD PORT STATUS UDLD Admin State The current port state of the logical port Enabled if any of state Normal Aggressive is Enabled Device ID local The ID of Device Device Name local Name of the Devi...

Page 385: ...neighbor port Device Name Name of the Neighbor Device Buttons The port select box determines which port is affected by clicking the buttons Auto refresh Check this box to refresh the page automatical...

Page 386: ...PLY will always be 8 bytes more than the requested data space the ICMP header The page refreshes automatically until responses to all packets are received or until a timeout occurs PING server 10 10 1...

Page 387: ...ieve the local or remote OAM MIB variable data on a particular port Select the appropriate radio button and enter the port number of the switch to retrieve the content of interest Click on to retrieve...

Page 388: ...me 0ms 64 bytes from fe80 215 58ff feed 69dd icmp_seq 1 time 0ms 64 bytes from fe80 219 5bff fe2f b47 icmp_seq 2 time 0ms 64 bytes from fe80 215 58ff feed 69dd icmp_seq 2 time 0ms 64 bytes from fe80 2...

Page 389: ...the corresponding IPv6 interface is valid When the egress interface is not given PING6 finds the best match interface for destination Do not specify egress interface for loopback address Do specify eg...

Page 390: ...an view the cable diagnostics results in the cable status table Note that VeriPHY is only accurate for cables of length 7 140 meters 10 and 100 Mbps ports will be linked down while running VeriPHY The...

Page 391: ...ross B Abnormal cross pair coupling with pair B Cross C Abnormal cross pair coupling with pair C Cross D Abnormal cross pair coupling with pair D Length The length in meters of the cable pair The reso...

Page 392: ...s available immediately which means that no restart is necessary Buttons Click to reset the configuration to Factory Defaults Click to return to the Port State page without restarting Note Restoring f...

Page 393: ...ick After the software image is uploaded a page announces that the firmware update is initiated After about a minute the firmware is updated and the switch restarts Warning While the firmware is being...

Page 394: ...image only the Active Image table is shown In this case the Activate Alternate Image button is also disabled 2 If the alternate image is active due to a corruption of the primary image or by manual i...

Page 395: ...available files are running config A virtual file that represents the currently active configuration on the switch This file is volatile startup config The startup configuration for the switch read at...

Page 396: ...96 DOWNLOAD CONFIGURATION Maintenance Configuration Download It is possible to download any of the files on the switch to the web browser Select the file and click Download of running config may take...

Page 397: ...then click If the destination is running config the file will be applied to the switch configuration This can be done in two ways Replace mode The current configuration is fully replaced with the conf...

Page 398: ...n Activate It is possible to activate any of the configuration files present on the switch except for running config which represents the currently active configuration Select the file to activate and...

Page 399: ...CONFIGURATION FILE Maintenance Configuration Delete It is possible to delete any of the writable files stored in flash including startup config If this is done and the switch is rebooted without a pr...

Page 400: ...d representative for all repairs WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense OUT OF WARRANTY REPAIRS OSD reserves th...

Page 401: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 401...

Page 402: ...uko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N...

Reviews: