Priority of Interface.
It indicates the MLD control frame priority level generated by the system. These values can be used to
prioritize different classes of traffic.
The allowed range is
0
(best effort) to
7
(highest), default interface priority value is 0.
RV
Robustness Variable.
The Robustness Variable allows tuning for the expected packet loss on a link.
The allowed range is
1
to
255
, default robustness variable value is 2.
QI
Query Interval.
The Query Interval is the interval between General Queries sent by the Querier.
The allowed range is
1
to
31744
seconds, default query interval is 125 seconds.
QRI
Query Response Interval.
The Maximum Response Delay used to calculate the Maximum Response Code inserted into the periodic
General Queries.
The allowed range is
0
to
31744
in tenths of seconds, default query response interval is 100 in tenths of
seconds (10 seconds).
Last Listener Query Interval.
The Last Listener Query Interval is the Maximum Response Delay used to calculate the Maximum
Response Code inserted into Multicast Address Specific Queries sent in response to Version 1 Multicast
Listener Done messages. It is also the Maximum Response Delay used to calculate the Maximum
Response Code inserted into Multicast Address and Source Specific Query messages.
The allowed range is
0
to
31744
in tenths of seconds, default last listener query interval is 10 in tenths
of seconds (1 second).
URI
Unsolicited Report Interval.
The Unsolicited Report Interval is the time between repetitions of a node's initial report of interest in a
multicast address.
The allowed range is
0
to
31744
seconds, default unsolicited report interval is 1 second.
Buttons
: Click to add new MLD VLAN. Specify the VID and configure the new
entry. Click "Save". The specific MLD VLAN starts working after the corresponding static
VLAN is also created.
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved values.
: Refreshes the displayed table starting from the input fields.
Summary of Contents for OSD2524
Page 2: ......
Page 14: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 14...
Page 26: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 26...
Page 234: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 234...
Page 339: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 339...
Page 401: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 401...