OPTICAL SYSTEMS DESIGN
DOC ID: 10120001
OSD2524 OPERATOR MANUAL
PAGE 282
DETAILED LINK OAM LINK STATUS FOR PORTS
Monitor
→
Link OAM
→
Event Status
This page allows the user to inspect the current Link OAM Link Event configurations, and
change them as well.
The left pane displays the Event status for the Local OAM unit while the right pane displays
the status for the Peer for the respective port.
Port
The switch port number.
Sequence Number
This two-octet field indicates the total number of events occurred at the remote end.
Frame Error Event Timestamp
This two-octet field indicates the time reference when the event was generated, in terms of 100ms
intervals.
Frame error event window
This two-octet field indicates the duration of the period in terms of 100 ms intervals. 1) The default value
is one second. 2) The lower bound is one second. 3) The upper bound is one minute.