APPENDIX
App. - 14
App. 4.6 Maintenance and service
WARNING
To avoid an electric shock, only qualified personnel should attempt inspections.
For repair and parts replacement, contact your local sales office.
App. 4.6.1 Inspection items
It is recommended that the following points periodically be checked.
(1) Check for loose terminal block screws. Retighten any loose screws.(Except for MR-J4-03A6 and MR-
J4W2-0303B6)
Servo amplifier
Tightening torque [N•m]
L1 L2 L3 N- P3 P4 P+ C D L11 L21 U V W PE
MR-J4-10_(1)/MR-J4-20_(1)/
MR-J4-40_(1)/ MR-J4-60_(4)/
MR-J4-70_/MR-J4-100_(4)/
MR-J4-200_(4)/MR-J4-350_(4)
1.2
MR-J4-500_
1.2
0.8 1.2
MR-J4-700_(4)/MR-J4-500_4
1.2
0.8 1.2
MR-J4-11K_(4)/MR-J4-15K_(4)
3.0
1.2 3.0
MR-J4-22K_(4)
6.0
1.2 6.0
MR-J4W_-_B
1.2
(2) Servo motor bearings, brake section, etc. for unusual noise.
(3) Check the cables and the like for scratches or cracks. Perform periodic inspection according to
operating conditions.
(4) Check that the connectors are securely connected to the servo motor.
(5) Check that the wires are not coming out from the connector.
(6) Check for dust accumulation on the servo amplifier.
(7) Check for unusual noise generated from the servo amplifier.
(8) Check the servo motor shaft and coupling for connection.
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......