18. MR-J4-03A6 SERVO AMPLIFIER
18 - 61
18.5.6 Alarm mode
The current alarm, past alarm history and parameter error are displayed. The alarm number that has
occurred or the parameter numbers in error are displayed on the display.
Name Display Description
Current alarm
Indicates no occurrence of an alarm.
2 s
interval
Indicates the occurrence of [AL. 33.1 Main
circuit voltage error].
Flickers at alarm occurrence.
The alarm number and detail number are
displayed alternately by intervals of 2s.
Alarm history
"SET"
Indicates that the last alarm is [AL. 50.1
Thermal overload error 1 during operation].
When an alarm is recorded to alarm history,
the second digit decimal point flickers.
Press and hold the "SET" button to show the
detail number of [AL. 50].
"SET"
Indicates the second last alarm is [AL. 33.1
Main circuit voltage error].
When an alarm is recorded to alarm history,
the second digit decimal point flickers.
Press and hold the "SET" button to show the
detail number of [AL. 33].
"SET"
"SET"
Indicates that there is no third alarm in the
past.
If there is no alarm history, the display will be
as shown as in the left, when the "SET"
button is pressed.
Indicates that there is no sixteenth alarm in
the past.
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......