11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 47
(4) Selection example of wires used for wiring
POINT
Selection condition of wire size is as follows.
Wire type: 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV
wire)
Construction condition: Single wire set in midair
(a) Wire sizes
1) Across P to P4, N to N
The following table indicates the connection wire sizes of the DC power supply (P4, N- terminals)
between the FR-CV and servo amplifier.
Total of servo amplifier capacities [kW]
Wire [mm
2
]
1 or less
2 (AWG 14)
2
3.5 (AWG 12)
5
5.5 (AWG 10)
7
8 (AWG 8)
11
14 (AWG 6)
15
22 (AWG 4)
22
50 (AWG 2)
The following table indicates the connection wire sizes of the DC power supply (P4, N- terminals)
between the FR-CV-H and servo amplifier.
Total of servo amplifier capacities [kW]
Wire [mm
2
]
11
8 (AWG 8)
15
8 (AWG 8)
22
14 (AWG 6)
2) Grounding
For grounding, use the wire of the size equal to or greater than that indicated in the following
table, and make it as short as possible.
Power regeneration common
converter
Grounding wire size
[mm
2
]
FR-CV-7.5K to FR-CV-15K
8 (AWG 8)
FR-CV-22K/FR-CV-30K
22 (AWG 4)
FR-CV-37K/FR-CV-55K
38 (AWG 2)
FR-CV-H22K/FR-CV-H30K
8 (AWG 8)
FR-CV-H37K/FR-CV-H55K
14 (AWG 6)
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......