5. PARAMETERS
5 - 43
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
P S T
PC19
*ENRS
Encoder
output pulse
selection
_ _ _ x Encoder output pulse phase selection
Select the encoder pulse direction.
0: A-phase 90° shift in CCW or positive direction
1: A-phase 90° shift in CW or negative direction
0h
Setting
value
Servo motor rotation direction/
linear servo motor travel direction
CCW or positive direction
CW or negative direction
0
A-phase
B-phase
A-phase
B-phase
1
A-phase
B-phase
A-phase
B-phase
_ _ x _ Encoder output pulse setting selection
0: Output pulse setting
When "_ 1 0 _" is set to this parameter, [AL. 37 Parameter error] will occur.
1: Dividing ratio setting
2: The same output pulse setting as the command pulse
3: A-phase/B-phase pulse electronic gear setting
4: A/B-phase pulse through output setting
When you select "1", the setting of [Pr. PA16 Encoder output pulses 2] will be
disabled. When you select "2", the settings of [Pr. PA15 Encoder output pulses] and
[Pr. PA16 Encoder output pulses 2] will be disabled. When you select the setting, do
not change the settings in [Pr. PA06] and [Pr. PA07] after the power-on.
Setting "4" will be enabled only when A/B/Z-phase differential output linear encoder is
used. And "Encoder output pulse phase selection (_ _ _ x)" will be disabled. When
another encoder is connected, [AL. 37 Parameter error] will occur. Setting "Standard
control mode (_ _ 0 _)" in [Pr. PA01] will trigger [AL. 37 Parameter error].
0h
_ x _ _ Selection of the encoders for encoder output pulse
Select an encoder for servo amplifier output.
0: Servo motor encoder
1: Load-side encoder
When "_ 1 0 _" is set to this parameter, [AL. 37 Parameter error] will occur.
This is only for the fully closed loop system.
If "1" is set other than in the fully closed loop system, [AL. 37 Parameter error] will
occur.
0h
x _ _ _ For manufacturer setting
0h
PC20
*SNO
Station No.
setting
Set a station No. of the servo amplifier for RS-422/RS-485 and USB communication.
Always set one station to one axis of the servo amplifier. Setting one station number
to two or more stations will disable a normal communication.
Setting range: 0 to 31
0
[Station]
PC21
*SOP
RS-422
communication
function
selection
Select the details of RS-422 communication function.
_ _ _ x For manufacturer setting
0h
_ _ x _ RS-422 communication baud rate selection
When using the parameter unit, set "1 _ _ _" in [Pr. PF34].
0: 9600 [bps]
1: 19200 [bps]
2: 38400 [bps]
3: 57600 [bps]
4: 115200 [bps]
0h
_ x _ _ RS-422 communication response delay time selection
0: Disabled
1: Enabled (responding after 800
μ
s or longer delay time)
0h
x _ _ _ For manufacturer setting
0h
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......