12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 3
12.1.4 Parameter setting
POINT
Set "_ _ _ 2" in [Pr. PA03] when using the absolute position detection system by
communication. This parameter setting is supported by servo amplifier with
software version A3 or later.
Set "_ _ _ 1" in [Pr. PA03] to enable the absolute position detection system. Set "_ _ _ 2" when using the
ABS transfer system by communication. Refer to section 12.8 for the ABS transfer system by
communication.
Absolute position detection system selection
0: Disabled (incremental system)
1: Enabled (absolute position detection system by DIO)
2: Enabled (absolute position detection system by communication-based)
(available for the software version A3 or later)
[Pr. PA03]
1
12.1.5 Confirmation of absolute position detection data
You can check the absolute position data with MR Configurator2. Choose "Monitor" and "ABS Data Display"
to open the absolute position data display screen.