18.5.4 One-touch tuning
The contents mentioned in this section is an operation method only for operating one-touch tuning on MR-
J4-03A6 servo amplifier by using push button. Refer to section 6.2 for details of one-touch tuning.
POINT
Push the "MODE" and "SET" buttons at the same time for 3 s or more to switch
to the response mode selection ("AT.") without going through the initial screen of
the one-touch tuning ("AT").
Push the "MODE" button during motor driving to switch to the initial screen ("AT") of the one-touch tuning.
Push the "SET" button for 2 s or more during displaying "AT" to switch to the response mode selection
("AT.").
(1) Response mode selection
Select a response mode of the one-touch tuning from 3 modes with "UP" or "DOWN". Refer to section
6.2.2 (1) (a) for a guideline of response mode.
Response mode selection display
Low mode: This mode is for low rigid system.
Basic mode: This mode is for standard system.
High mode: This mode is for high rigid system.
DOWN
UP
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......