3. SIGNALS AND WIRING
3 - 24
(b) MR-J4-200A(-RJ)/MR-J4-350A(-RJ)
CNP2
CNP1
CNP3
MR-J4-200A(-RJ)
Servo amplifier
CNP3
CNP1
CNP2
MR-J4-350A(-RJ)
Servo amplifier
Table 3.2 Connector and applicable wire
Connector Receptacle
assembly
Applicable wire
Stripped
length [mm]
Open tool
Manufa
cturer
Size Insulator
OD
CNP1 06JFAT-SAXGFK-XL
AWG16 to 10
4.7 mm or shorter
11.5
J-FAT-OT-EXL JST
CNP3 03JFAT-SAXGFK-XL
CNP2
05JFAT-SAXGDK-H5.0
AWG18 to 14
3.9 mm or shorter
9
(c) MR-J4-60A4(-RJ) to MR-J4-350A4(-RJ)
CNP2
CNP1
(Note)
CNP3
Servo amplifier
Note. A pin for preventing improper connection is inserted to N- of CNP1 connector.
Table 3.3 Connector and applicable wire
Connector Receptacle
assembly
Applicable wire
Stripped
length [mm]
Open tool
Manufa
cturer
Size Insulator
OD
CNP1 06JFAT-SAXGDK-HT10.5
AWG 16 to 14
3.9 mm or shorter
10
J-FAT-OT-XL
JST
CNP2 05JFAT-SAXGDK-HT7.5
CNP3 03JFAT-SAXGDK-HT10.5
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......