14. COMMUNICATION FUNCTION (MITSUBISHI GENERAL-PURPOSE AC SERVO PROTOCOL)
14 - 36
14.5.10 Alarm history
(1) Alarm No. reading
The following shows how to read alarm Nos. which occurred in the past. Alarm Nos. and occurrence
times of No. 0 (last alarm) to No. 15 (sixteenth alarm in the past) are read.
(a) Transmission
Transmit command [3] [3] + data No. [1] [0] to [1] [F]. Refer to section 14.4.1.
(b) Return
Alarm Nos. corresponding to the data No. is provided.
0 0
Alarm No. is transferred in hexadecimal.
For example, "0032" means [AL. 32] and "00FF" means [AL. _ _ ] (no alarm).
(2) Alarm occurrence time reading
The following shows how to read alarm occurrence times which occurred in the past.
Alarm occurrence time corresponding to the data No. is provided in terms of the total time beginning with
operation start, with the minute unit omitted.
(a) Transmission
Transmit command [3] [3] + data No. [2] [0] to [2] [F].
Refer to section 14.4.1.
(b) Return
The alarm occurrence time is transferred in hexadecimal.
Hexadecimal must be converted into decimal.
For example, data "01F5" means that the alarm occurred in 501 hours after starting operation.
(3) Clearing the alarm history
Alarm history is cleared.
Transmit command [8] [2] and data No. [2] [0].
Command
Data No.
Data
[8] [2]
[2] [0]
1EA5
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......