12. ABSOLUTE POSITION DETECTION SYSTEM
12 - 24
(1) The off period of the ABS transmission data ready signal output from the servo amplifier is checked. If
the off period is 1 s or longer, regard as a transfer fault and generate the ABS communication error.
Generate the ABS communication error if [AL. E5 ABS time-out warning] is generated at the servo
amplifier due to an ABS request on time time-out.
OFF
ON
OFF
ON
OFF
ON
1 s
ABSM
ABSR
ABST
ABS communication
error
The signal does not come ON
NO
YES
(2) The time required for the ABS transfer mode signal to go off after it has been turned on (ABS transfer
time) is checked. If the ABS transfer time is longer than 5 s, regard that a transfer fault has occurred,
and generate the ABS communication error. Generate the ABS communication error if [AL. E5 ABS
time-out warning] is generated at the servo amplifier due to an ABS transfer mode completion time time-
out.
OFF
ON
OFF
ON
OFF
ON
1
2
3
4
18
19
1
2
3
4
18
19
5 s
ABSM
ABSR
ABST
ABS communication
error
The signal does not go OFF
NO
YES
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......