13. USING STO FUNCTION
13 - 5
13.2.2 Signal (device) explanations
(1) I/O device
Signal name
Connector
pin No.
Description
I/O
division
STOCOM
CN8-3
Common terminal for input signal of STO1 and STO2
DI-1
STO1
CN8-4
Inputs STO state 1.
STO state (base shut-off): Open between STO1 and STOCOM.
STO release state (in driving): Close between STO1 and STOCOM.
Be sure to turn off STO1 after the servo motor stops by the servo-off state or with forced
stop deceleration by turning off EM2 (Forced stop 2).
DI-1
STO2
CN8-5
Inputs STO state 2.
STO state (base shut-off): Open between STO2 and STOCOM.
STO release state (in driving): Close between STO2 and STOCOM.
Be sure to turn off STO2 after the servo motor stops by the servo-off state or with forced
stop deceleration by turning off EM2 (Forced stop 2).
DI-1
TOFCOM
CN8-8
Common terminal for monitor output signal in STO state
DO-1
TOFB1
CN8-6
Monitor output signal in STO1 state
STO state (base shut-off): Between TOFB1 and TOFCOM is closed.
STO release state (in driving): Between TOFB1 and TOFCOM is opened.
DO-1
TOFB2
CN8-7
Monitor output signal in STO2 state
STO state (base shut-off): Between TOFB2 and TOFCOM is closed.
STO release state (in driving): Between TOFB2 and TOFCOM is opened.
DO-1
(2) Signals and STO state
The following table shows the TOFB and STO states when the power is on in normal state and STO1
and STO2 are on (closed) or off (opened).
Input signal
State
STO1 STO2
Between TOFB1 and TOFCOM
(Monitoring STO1 state)
Between TOFB2 and TOFCOM
(Monitoring STO2 state)
Between TOFB1 and TOFB2
(Monitoring STO state of servo
amplifier)
Off
Off
On: STO state (base circuit shut-off) On: STO state (base circuit shut-off) On: STO state (base circuit shut-off)
Off
On
On: STO state (base circuit shut-off) Off: STO release state
Off: STO state (base circuit shut-off)
On
Off
Off: STO release state
On: STO state (base circuit shut-off) Off: STO state (base circuit shut-off)
On
On
Off: STO release state
Off: STO release state
Off: STO release state
(3) Test pulse of STO input signal
Set the test pulse off time inputted from outside to 1 ms or less.
13.2.3 How to pull out the STO cable
The following shows how to pull out the STO cable from the CN8 connector of the servo amplifier.
1)
2)
While pressing knob 1) of the STO cable plug in the
direction of the arrow, pull out the plug 2).
(This figure shows the MR-J4-_B_(-RJ) servo amplifier.
This procedure also applies to the MR-J4-_A_(-RJ) servo
amplifier.)
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......