11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 49
(5) Other precautions
(a) When using the FR-CV-(H), always install the dedicated stand-alone reactor (FR-CVL-(H)). Do not
use the power factor improving AC reactor (FR-HAL-(H)) or Power factor improving DC reactor (FR-
HEL-(H)).
(b) The inputs/outputs (main circuits) of the FR-CV-(H) and servo amplifiers include high-frequency
components and may provide electromagnetic wave interference to communication equipment (such
as AM radios) used near them. In this case, interference can be reduced by installing the radio noise
filter (FR-BIF-(H)) or line noise filter (FR-BSF01, FR-BLF).
(c) The overall wiring length for connection of the DC power supply between the FR-CV-(H) and servo
amplifiers should be 5 m or less, and the wiring must be twisted.
(6) Specifications
Power regeneration
common converter
FR-CV-_
Item
7.5K 11K 15K 22K 30K 37K 55K
Total of connectable servo amplifier
capacities
[kW] 3.75
5.5
7.5
11
15
18.5
27.5
Maximum servo amplifier capacity
[kW]
3.5
5
7
11
15
15
22
Output
Total of connectable servo
motor rated currents
[A]
33 46 61 90 115 145
215
Regenerative
braking torque
Short-time rating
Total capacity of applicable servo motors, 300% torque, 60s (Note 1)
Continuous rating
100% torque
Power
supply
Rated input AC voltage/frequency
3-phase 200 V AC to 220 V AC, 50 Hz, 200 V AC to 230 V AC, 60 Hz
Permissible AC voltage fluctuation
3-phase 170 V AC to 242 V AC, 50 Hz, 170 V AC to 253 V AC, 60 Hz
Permissible frequency fluctuation
±5%
Power supply capacity (Note 2) [kVA]
17
20
28
41
52
66
100
IP rating (JEM 1030), cooling method
Open type (IP00), forced cooling
Environment
Ambient temperature
-10 °C to 50 °C (non-freezing)
Ambient humidity
90 %RH or less (non-condensing)
Ambience
Indoors (no direct sunlight), free from corrosive gas, flammable gas, oil mist, dust,
and dirt
Altitude, vibration resistance
1000 m or less above sea level, 5.9 m/s
2
Molded-case circuit breaker or earth-
leakage current breaker
30 AF
30 A
50 AF
50 A
100 AF
75 A
100 AF
100 A
125AF
125 A
125AF
125 A
225 AF
175 A
Magnetic contactor
S-N20
S-N35
S-N50 S-N65 S-N80 S-N95 S-N125
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......