18. MR-J4-03A6 SERVO AMPLIFIER
18 - 56
(4) If an error occurs
Check the error cause referring table 6.2 of (1) (d) of section 6.2.2.
2 s
interval
Error code
If an error occurs during the one-touch tuning, the tuning will be forcibly terminated and the
stop symbol and error code from "C 01" to "C 0F" will be displayed by turns with 2 s
interval.
Stop symbol
Initial screen
Pushing the "SET" button will switch to the initial screen.
(5) If an alarm occurs
If an alarm occurs during tuning, one-touch tuning will be forcibly terminated and the alarm
No. will be displayed.
One-touch tuning in progress
Alarm display
2 s
interval