11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 32
(4) Cables
(a) Cables for the brake unit
For the brake unit, HIV cable (600 V grade heat-resistant PVC insulated wire) is recommended.
1) Main circuit terminal
N/-
P/+
PR
Terminal block
Brake unit
Main
circuit
terminal
screw
size
Crimp
terminal
Tightening
torque
[N•m]
Wire size
N/-, P/+,
PR,
N/-, P/+, PR,
HIV wire
[mm
2
]
AWG
200 V
class
FR-BU2-15K M4
5.5-4
1.5
3.5
12
FR-BU2-30K M5
5.5-5
2.5
5.5
10
FR-BU2-55K
M6 14-6 4.4 14
6
400
V
class
FR-BU2-H30K
M4 5.5-4 1.5 3.5
12
FR-BU2-H55K
M5
5.5-5
2.5
5.5
10
FR-BU2-H75K
M6 14-6 4.4 14
6
2) Control circuit terminal
POINT
Under tightening can cause a cable disconnection or malfunction. Over
tightening can cause a short circuit or malfunction due to damage to the screw
or the brake unit.
A
RES
PC
B
SD
BUE
C
MSG
SD
MSG
SD SD
Jumper
Terminal block
Insulator
Core
6 mm
Wire the stripped cable after twisting to prevent the cable
from becoming loose. In addition, do not solder it.
Screw size: M3
Tightening torque: 0.5 N•m to 0.6 N•m
Wire size: 0.3 mm
2
to 0.75 mm
2
Screw driver: Small flat-blade screw driver
(Tip thickness: 0.4 mm/Tip width 2.5 mm)
(b) Cables for connecting the servo amplifier and a distribution terminal block when connecting two sets
of the brake unit
Brake unit
Wire size
HIV wire [mm
2
]
AWG
FR-BU2-15K 8 8
Summary of Contents for MR-J4
Page 9: ...A 8 MEMO ...
Page 19: ...10 MEMO ...
Page 73: ...1 FUNCTIONS AND CONFIGURATION 1 54 MEMO ...
Page 155: ...3 SIGNALS AND WIRING 3 76 MEMO ...
Page 199: ...4 STARTUP 4 44 MEMO ...
Page 289: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 335: ...8 TROUBLESHOOTING 8 8 MEMO ...
Page 357: ...9 OUTLINE DRAWINGS 9 22 MEMO ...
Page 517: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 30 MEMO ...
Page 617: ...16 USING A DIRECT DRIVE MOTOR 16 20 MEMO ...
Page 641: ...17 FULLY CLOSED LOOP SYSTEM 17 24 MEMO ...
Page 725: ...18 MR J4 03A6 SERVO AMPLIFIER 18 84 MEMO ...
Page 763: ...APPENDIX App 38 ...
Page 789: ...MEMO ...
Page 793: ......