Chapter 4 Running
108
by TRQ1 and TRQ2 from DI inputs.
Note: 1.The final limitation value will be the smallest value if many limits occur.
2. The limit of the P065 and the P066 is effective all the time.
3. Even if the setting value greater than the permission maximum speed of the system,
but the operation also can limit in the maximum torque range.
The inner torque commands are:
DI Signals[Note]
Torque command
TRQ2 TRQ1
0
0
Internal torque 1 (parameter P145)
0
1
Internal torque 2 (parameter P1456)
1
0
Internal torque 3 (parameter P147)
1
1
Internal torque 4 (parameter P148)
Note: 0 indicates OFF, 1indicates ON.