5.5 DI function description in detail
175
5.5 DI function description in detail
Ordi
nal
Symbol
Function
Function explanation
0 NULL
Not have
function
The input condition does not have any influence to the
system.
1 SON
Servo
enable
OFF
:
servo driver does not enable, servomotor does not
excite;
ON
:
servo driver has enabled, servomotor has excited.
2 ARST
Clear
alarm
When an alarm occurs and the alarm has permission to clear,
then the rising edge (from OFF becomes ON) of input signal
ARST will clear the alarm. Attention: only a part of alarm
can have the permission to clear.
3 CCWL
CCW
drive
inhibition
OFF
:
Inhibit CCW running;
ON
:
Enable CCW running.
Uses this function for protection of the mechanical
traveling limit, the function is controlled by the parameter
P097. Pays attention to that the P097 default value neglects
this function, therefore needs to modify P097 if needs to use
this function:
P097 Explanation
0
Use CCW prohibition function and
must connect the normally closed
contact of the limit switch.
2
1
Neglect CCW prohibition function, this
signal does not have any influence to
CCW movement of the servomotor,
and therefore does not need the CCWL
wiring.
3(Defaul
t)
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...