7.2 The reason and handling of alarm
203
Err 8 (Overflow of position deviation counter)
Potential cause
Check
Handle
The servomotor is blocked Check the servomotor
shaft and its mechanical
connection
Repair.
The command pulse is
abnormal
Check command pulse
Err 9 (Encoder signal fault)
Potential cause
Check
Handle
Encoder wiring error
Check the encoder wiring
Correct wiring
Encoder cable and/or
connector is bad
Check cable and connector
Replace the cable and connector.
Servomotor type setting is
not correct.
Check the servomotor type
Set the servomotor type again.
Encoder is damaged
Check the encoder
Replace the encoder.
Err11 (IGBT model fault)
Potential cause
Check
Handle
Short-circuit at drive
output (U
、
V
、
W)
Check U
、
V
、
W
wiring Repair or replace the
short-circuited wiring.
Motor winding insulation
is damaged
Check the servomotor
Replace the servo motor
Servo driver is damaged
Check the servo driver
Known the servomotor to be no
fault, and then turn on the power
supply again, if the alarm still
exists, the servo driver may damage
possibly. Replace the servo driver.
Ground is bad
Check the ground wiring
Ground correctly.
Suffer from interference
Check interference source Adds line filter; Keep away
interference source.
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...