4.4 Torque control mode
71
4.4.2 Parameters related to torque commands
The following table is the parameters related to the torque command:
Param
eter
Name
Range
Default
value
Unit
Usag
e
P026
Source of torque command
0
~
2 0
T
P053
Gain of analog torque command
1
~
300 30
%/V
T
P054
Zero offset compensation of
analog torque command
-1500.0
~
1500.0
0.0 mv T
P055
Direction of analog torque
command
0
~
1 0
T
P056
Time constant of filter for
analog torque command
0.20
~
50.00 2.00 ms T
P057
Polarity of analog torque
command
0
~
2 0
T
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...