Chapter 4 Running
84
vibration occurs then increase the time constant a bit.
5. Increase the gain of position loop, if vibration occurs then decreases the gain a bit.
6. Because the mechanical system may have resonating factors and is unable to adjust for a bigger
gain, then the desired response cannot obtain. Now, use low pass or notch filter for torque to
suppress the resonance, and then carry on above steps again enhancing responsiveness. First
use the low pass filter of torque, if the effect is not good then use notch filter again. Please
refer to 4.7 sections about resonance suppression.
7. If need shorter positioning time and smaller position tracking error, can adjust the feed forward
of the position loop. Please refer to 4.2.4 section