Chapter 4 Running
96
4.9.5 Timing chart of homing for combination mode
For homing, the reference point mode (P179) and the origin mode (P180) cab be combined
and have the following combinations. The detailed actions of each combined mode refer to 4.9.3
section.
(A) P179=0 or 2/P180=0
Parameter
Setting
explanation
P179
0 or 2
After starts homing, seek REF (rising edge trigger) or CCWL
(falling edge trigger) in CCW direction with first speed (P183)
and take it the reference point.
P180
0
After found the reference point, seek Z pulse in backward
direction with second speed (P184) and take it the origin.
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...