Chapter 5 Parameters
120
param
eter
name
range
Default
value
unit
usage
P182
misalignment bottom digit of homing
-9999
~
9999
0 pulse
ALL
P183
First speed of homing
1
~
3000
500 r/min
ALL
P184
Second speed of homing
1
~
3000
50 r/min
ALL
P185
Acceleration time of homing
0
~
30000
0 ms
ALL
P186
Deceleration time of homing
0
~
30000
0 ms
ALL
P187
Positioning time delay of homing
0
~
3000
50 ms
ALL
P188
Delay time of complete signal after
homing
1
~
3000
100 ms
ALL
P189
Command executive mode after homing
0
~
1
0
ALL