2.2 X1 terminals for control signals
19
2.2.3 X1 terminal interface type
The followings introduce the X1 various interface circuits and the wiring ways with the
host-controller.
1. Digital input interfaces (C1)
For carrying on a control, the digital input interface circuit can be constructed by switch,
relay, open-collector triode, and photo-coupler and so on. To avoid contacting problem the relay
must be chosen with low current operation. External voltage is in the range of DC12V~24V.
C1-1: Switch input
C1-2: Open collector triode
2. Digital output interfaces (C2)
The digital outputs use Darlington photo-coupler. It can be connected with relay,
photo-coupler. Matters of note are:
Inverting the polarity of DC power source, which is provided by the user, can cause the
servo driver damage.
The maximum voltage of external DC power supply is 25V, the maximum output current is
50mA, and the total current for three channels is not in excess of 100mA.
When using relay like inductive loads, a free-wheel diode must be connected with the
inductive load in parallel. If the diode connects in wrong direction can cause damage to the
output circuit.
Owing to the low level of output is approximately 1V and cannot satisfy the TTL low-level
request, therefore cannot directly connect with the TTL circuit.
C2-1: Relay
C2-2: Photo coupler
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...