Chapter 2 Wiring
12
2.1.4 Main circuit terminal explanation
Terminal
name
Symbol
Model
Detailed explanation
Main power
supply
L1
、
L2 EP3-GL1A0
、
EP3-GL1A8
EP3-GL3A0
1 phase 220VAC -15%
~
+10% 50/60Hz
L1
、
L2
、
L3
EP3-GL7A5
、
EP3-GL120
EP3-GL160
、
EP3-GL190
EP3-GL240
3 phase 220VAC -15%
~
+10% 50/60Hz
EP3-GH series
3 phase 380VAC -15%
~
+10% 50/60Hz
Control
power
supply
L1C
、
L2C
EP3-GL series
1 phase 220VAC -15%
~
+10% 50/60Hz
24V
、
0V
EP3-GH series
Connect DC 24V
externally
Brake
resistor
P
、
B1
、
B2
EP3-GL1A0
、
EP3-GL1A8
EP3-GL3A0
、
EP3-GL7A5
EP3-GL120
、
EP3-GL160
EP3-GH3A5
、
EP3-GH5A4
When the external brake
resistor is needed,
disconnect the short wires
between B1 and B2 [note
2] and crossover the
external brake resistor to
terminals P and B1. Leave
B2 unconnected.
NC
、
P
、
B
EP3-GL190
、
EP3-GL240
【
note 1
】
EP3-GH8A5
、
EP3-GH130
EP3-GH170
When the external brake
resistor is needed, it must
disconnect the internal
brake resistor wire between
terminals P and B firstly,
connect those two wires to
NC at the same time, and
then crossover the external
brake resistor to terminals
P and B.
Power
supply
higher order
harmonics
restrain-use
N1
、
N2
EP3-GL190
、
EP3-GL240
EP3-GH3A5
、
EP3-GH5A4
EP3-GH8A5
、
EP3-GH130
When the power supply
higher order harmonics
needs to be restrained,
connect the DC reactor
between N1 and N2[note 2]
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...