Chapter 4 Running
58
4
5
)
1
/
1
(
8000
10000
)
(
ratio
gear
Electronic
R
P
P
M
N
c
t
Set parameters (By first numerator as an example)
Numerator N=5
,
denominator M=4
,
set P029=5and P030=4
。
2. Electronic gear is used for graduator drive
The graduator load has
R
P
P
M
N
c
t
)
(
ratio
gear
Electronic
Here,
P
360
P
c
Take the absolute encoder for example:
Known that the encoder bit C=17 bits, the reducer gear ratio 1/3, a pulse travel equivalent
Δ
P=0.1°Calculate the electronic gear ratio.
Calculation step:
Calculate the resolution of the encoder (P
t
)
)
/
(
10000
1
10000
P028
P027
P
t
rev
pulse
Calculate the command pulse numbers for one turn of the load shaft (P
c
)
3600
1
.
0
360
360
P
c
P
Calculate the electronic gear ratio