4.3 Speed control mode
65
4.3.2 Parameters related to speed commands
The following table is the parameters related to the speed command:
Param
eter
Name
Range
Default
value
Unit
Usage
P025
Source of speed command
0
~
5 0
S
P046
Gain of analog speed command
10
~
3000 300
r/min/
V
S
P047
Zero offset compensation of
analog speed command
-1500.0
~
1500.0
0.0 mv S
P048
Direction of analog speed
command
0
~
1 0
S
P049
Time constant of filter for
analog speed command
0.20
~
50.00 2.00 ms S
P050
Polarity of analog speed
command
0
~
2 0
S
P051
Dead zone 1 of analog speed
command
0
~
13000 0
mv
S
P052
Dead zone 2 of analog speed
command
-13000
~
0 0
mv
S
P076
Running speed of JOG
0
~
5000 100
r/min
S
4.3.3 Sources of the speed commands
The sources of speed command determined by parameter P025:
P025
Explanation
Interpret
0
Analog speed command
From terminal AS+ and AS- inputs analog
voltage.
1
Internal speed command
Determine on SP1
、
SP2
、
SP3 of DI inputs
[Note1]
2
Analog speed c
Internal speed command
Act as analog speed command when SP1, SP2,
SP3 are OFF. The rest Determine on SP1
、
SP2
、
SP3 [Note2].
3
speed command
Set for JOG operation.
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...