204
Err12 (Over-current)
Potential cause
Check
Handle
Short-circuit at drive
output (U
、
V
、
W)
Check the wiring
connections between servo
driver and servomotor.
Repair or replace the
short-circuited wiring.
Motor winding insulation
is damaged
Check the servomotor
Replace the servomotor.
Servo driver is damaged
Check the servo driver
Known the servomotor to be
nofault, and then turn on the
power supply again, if the alarm
still exists, the servo driver may
damage possibly. Replace the
servo driver.
Err13 (Over-load)
Potential cause
Check
Handle
Excess the rated load for
continuous duty operation
Check the load factor
Reduce load or replace the servo
driver with bigger one.
System unstable
Check the oscillation when
servomotor is in running
Reduce the gains of the system
Acceleration/deceleration is
too short
Check the smoothness
when servomotor is in
running
Increasing
acceleration/deceleration time
setting.
Encoder zero point changes Check the encoder zero
point
Install the encoder again and adjust
the zero point.
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...