Chapter 5 Parameters
148
P102
Function of digital input DI3
Range
Default
value
Unit
Usag
e
-30
~
30
3
ALL
The function plan of digital input DI3. Refer to the explanation of parameter P100.
P103
Function of digital input DI4
Range
Default
value
Unit
Usag
e
-30
~
30
4
ALL
The function plan of digital input DI4. Refer to the explanation of parameter P100.
P104
Function of digital input DI5
Range
Default
value
Unit
Usag
e
-30
~
30
20
ALL
The function plan of digital input DI5. Refer to the explanation of parameter P100.
P110
Filter of digital input DI1
Range
Default
value
Unit
Usag
e
0.1
~
100.0
2.0
ms
ALL
This is the time-constant of DI1 input digital filter.
The smaller the value, the quicker signal responses; the bigger the value, the slower signal
responses, but filtering ability of noise is stronger.
P111
Filter of digital input DI2
Range
Default
value
Unit
Usag
e
0.1
~
100.0
2.0
ms
ALL
This is the time-constant of DI2 input digital filter. Refer to the explanation of parameter
P110.
P112
Filter of digital input DI3
Range
Default
value
Unit
Usag
e
0.1
~
100.0
2.0
ms
ALL
This is the time-constant of DI3 input digital filter. Refer to the explanation of parameter
P110.
P113
Filter of digital input DI4
Range
Default
value
Unit
Usag
e
0.1
~
100.0
2.0
ms
ALL
This is the time-constant of DI4 input digital filter. Refer to the explanation of parameter
P110.
P114
Filter of digital input DI5
Range
Default
value
Unit
Usag
e
0.1
~
100.0
2.0
ms
ALL
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...