5.4 Parameter description in detail
135
P037
Input signal logic of command
pulse
Range
Default
value
Unit
Usag
e
0
~
3
0
P
Set the phase of the input pulse signals PULS and SIGN for adjusting the counting edge as
well as the counting direction.
P037
PULS signal
phase
SIGN signal phase
0
In phase
In phase
1 Opposite
phase In
phase
2 In
phase
Opposite
phase
3
Opposite phase
Opposite phase
The parameter needs to preserve firstly and then turn off and on the power supply.
P038
Input signal filter of command
pulse
Range
Default
value
Unit
Usag
e
0
~
21
7
P
Filter the input signal PULS and SIGN numerically. The value is bigger then the filter
time-constant is bigger.
The maximum input pulse frequency is 500 kHz (kpps) when the setting value is seven. If
the value is bigger, the maximum input pulse frequency will reduce correspondingly.
Filter the noise from the input signal to avoid counting mistake. Because if found the
running not perfect caused by the counting pulse, then can suitably increase the parameter
value.
The parameter needs to preserve firstly and then turn off and on the power supply.
P039
Input filter mode of command
pulse I
Range
Default
value
Unit
Usag
e
0
~
1
0
P
The meanings of this parameter are:
0
:
Filter the input signal PULS and SIGN numerically.
1
:
Filter the input signal PULS only and not filter the SIGN signal.
The parameter needs to preserve firstly and then turn off and on the power supply.
P040
Time-constant of exponential form
filter for position command
Range
Default
value
Unit
Usag
e
0
~
1000
0
ms
P
Carries on the smooth filter to the command pulse and has the exponential form
acceleration/deceleration. The filter cannot lose the input pulse, but can delay the command
pulse. When the setting value is zero, the filter does not have any effect.
This filter uses in some cases:
1. The host controller has no acceleration/deceleration function;
2. The electronic gear ratio is quite big (N/M>10);
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...