Chapter 4 Running
98
(D) P179=1/P180=1
Parameter
Setting
Explanation
P179
1
After starts homing, seek REF (rising edge trigger) in CW
direction with first speed (P183) and take it the reference point.
P180
1
After found the reference point, seek Z pulse in forward direction
with second speed (P184) and take it the origin.
(E) P179=0/P180=2
Parameter
Setting
Explanation
P179
0
After starts homing, seek REF (rising edge trigger) in CCW
direction with first speed (P183) and take it the reference point.
P180
2
After found the reference point, directly make it the origin.
(F) P179=1/P180=2
Parameter
Setting
Explanation
P179
1
After starts homing, seek REF (rising edge trigger) in CW
direction with first speed (P183) and take it the reference point.
P180
2
After found the reference point, directly make it the origin.