5.4 Parameter description in detail
161
P189
Command executive mode after
homing
Range
Default
value
Unit
Usag
e
0
~
1
0
ALL
The meanings of this parameter are:
0
:
After the homing completed, waiting for the HOME signal becomes OFF and then carries
out the command again.
1
:
After the homing completed carries out the command immediately.
5.4.3 Parameters of section 2
P200
Frequency of first notch filter
Range
Default
value
Unit
Usag
e
50
~
1500
1500
Hz
ALL
Notch filter is the filter for eliminating the specific frequency resonance caused by
machinery.
If the parameter P202 sets zero, then closes the notch filter.
P201
Quality factor of first notch filter
Range
Default
value
Unit
Usag
e
1
~
100
7
ALL
The quality factor Q indicates the shape of notch filter. The bigger the quality factor Q, the
more incisive of the north shape and the narrower of bandwidth (-3dB) obtain.
h
North Widt
frequency
North
Q
factor
Quality
P202
Depth of first notch filter
Range
Default
value
Unit
Usag
e
0
~
100
0
%
ALL
Summary of Contents for EP3 AC Series
Page 1: ...Wuhan Maxsine Electric Co Ltd...
Page 12: ...Chapter 1 Product inspection and installment 2 1 2 Product nameplate...
Page 16: ...Chapter 1 Product inspection and installment 6...
Page 40: ...Chapter 2 Wiring 30 2 5 2 Wiring diagram for speed or torque control...
Page 57: ...3 7 Resume the parameter default values 47 Remarks...
Page 124: ...Chapter 4 Running 114 Remarks...
Page 221: ...198 Chapter 8 Specifications 8 1 Types of servo driver...
Page 231: ...8 5 Types of servo motor 8 5 Types of servo motor...