Prefix:
PLAT
ID:
0520
User Response
Complete the following step to solve PCI I/O resource errors:
1.
Go to F1 Setup
2.
System Settings
3.
Device and I/O ports
4. PCI 64 bit Resource and choose enable
•
80070114-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state. (TPM Phy Pres Set)
This message is for the use case when an implementation has detected a Sensor transitioned to
non-critical from normal.
May also be shown as 800701142201ffff or 0x800701142201ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix:
PLAT
ID:
0520
User Response
1. Complete the administrative tasks that require the TPM physical presence switch to be in
the ON position.
2. Restore the physical presence switch to the OFF position.
3.
Reboot the system.
4. (Trained technician only) If the error continues, replace the planar.
•
80070201-0301ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state. (CPU 1 OverTemp)
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702010301ffff or 0x800702010301ffff
Appendix A. Integrated management module II (IMM2) error messages
455
Summary of Contents for x3650 M4 BD 5466
Page 1: ...Lenovo System x3650 M4 Installation and Service Guide Machine Type 7915 ...
Page 6: ...iv Lenovo System x3650 M4 Installation and Service Guide ...
Page 176: ...164 Lenovo System x3650 M4 Installation and Service Guide ...
Page 226: ...214 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1042: ...1030 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1200: ...1188 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1204: ...1192 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1212: ...Taiwan BSMI RoHS declaration 1200 Lenovo System x3650 M4 Installation and Service Guide ...
Page 1221: ......
Page 1222: ......