To install the 16x2.5-inch Hot-Swap HDD Assembly Kit for 12Gb/6Gb RAID, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v and “Installation guidelines”
on page 34.
Step 2.
Turn off the server and peripheral devices and disconnect the power cords and all external cables,
if necessary.
Step 3.
Remove the cover (see “Removing the cover” on page 37).
Step 4.
Remove the two 4-drive filler panels that are to the right of drive bay 8, beneath the IDs 8 - 15 on
the front bezel.
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
4-drive
filler panel
Figure 85. Filler panels
Step 5.
To obtain more working room, remove fans 2 and 3 (see “Removing a hot-swap fan” on page 311).
Step 6.
Install the new backplane in slot 2: