Summary of Contents for E6650A EXF

Page 1: ...for Femtocell V9065B Sequence Analyzer User s Programmer s Reference Keysight Wireless Connectivity Test Set Notice This document contains references to Agilent Please note that Agilent s Test and Mea...

Page 2: ...ional government requirements beyond those set forth in the EULA shall apply except to the extent that those terms rights or licenses are explicitly required from all providers of commercial computer...

Page 3: ...About the Sequence Analyzer Application 35 What Does the Sequence Analyzer Application Do 36 2 Programming the Test Set 37 What Programming Information is Available 38 List of SCPI Commands 39 STATus...

Page 4: ...Frequency Register 75 Questionable Frequency Condition 75 Questionable Frequency Enable 75 Questionable Frequency Event Query 76 Questionable Frequency Negative Transition 76 Questionable Frequency Po...

Page 5: ...Instrument State 91 Service Request Enable 92 Status Byte Query 92 Trigger 92 Self Test Query 93 Wait to Continue 93 3 Input Output Functions 95 Input Output 96 Input Output variables Preset behavior...

Page 6: ...F Output 117 RF Output 118 RFIO1 118 RFIO2 118 HalfDuplex Config 119 RF Input 119 RF Output 119 Output Config 120 Trig Out 120 Polarity 121 Off 121 Sweeping HSWP 121 Measuring 121 Main Trigger 122 Gat...

Page 7: ...ion Remote Commands Only 136 Current Application Model 136 Current Application Revision 137 Current Application Options 137 Application Identification Catalog Remote Commands Only 138 Detailed List of...

Page 8: ...Remote Commands Remote Commands Only 158 System Powerdown Remote Command Only 159 List installed Options Remote Command Only 159 Lock the Front panel keys Remote Command Only 159 List SCPI Commands Re...

Page 9: ...Configuration list Remote Command Only 172 Configuration Memory Available Remote Command Only 173 Configuration Memory Total Remote Command Only 173 Configuration Memory Used Remote Command Only 173 C...

Page 10: ...Commands Only 201 Advanced 201 Key Recorder 202 Self test 202 All Self Test 203 FEC Self Test 203 Show Result 203 Internet Explorer 205 6 Trigger Functions 207 6 List Sequence Measurements 207 File 2...

Page 11: ...Sequence Analyzer 225 2 225 If the Sequence is aborted manually then results return 1 225 Mode Sequence Analyzer 225 3 225 If the Sequence is aborted manually then results return 1 1 1 225 Example for...

Page 12: ...d Only 279 Reset Fast Power Measurement Remote Command Only 279 Define Fast Power Measurement Remote Command Only 280 Define Fast Power Measurement Query Remote Command Only 289 Configure Fast Power M...

Page 13: ...Bandwidth Meas Setup 327 Modulation Accuracy Meas Setup 328 WCDMa RHO 330 TDSCDMA RHO 331 WLAN Modulation Accuracy 332 WLAN MIMO Modulation Accuracy 338 QPSK EVM Meas Setup 339 Code Domain Power Meas...

Page 14: ...n 358 TDSCDMA Demod Mod Scheme 358 More Information about Mode Scheme 358 TDSCDMA Demod Channel Configuration 359 Select Code Length 359 Select All Code Channels 360 Select Code Channel 360 Code Chann...

Page 15: ...ore Acquisition 384 Delete Acquisition 384 Avg Number 385 Logarithmic Averaging 393 Linear Averaging 393 Last Value Averaging 393 Min Hold Averaging 394 Max Hold Averaging 394 Abs Linear Averaging 394...

Page 16: ...map 440 Expected Power at DUT Output 450 Basic Meas Setup 451 Basic Transmit Power Setup 451 Upper Limit 452 Lower Limit 453 Radio Standard None 454 Basic Frequency and Phase Error Setup 457 Digital I...

Page 17: ...w To Preset 476 Print 478 Quick Save 479 Recall 481 State 481 More Information 483 From File 483 Edit Register Names 485 Register 1 thru Register 16 485 Register 1 thru Register 16 486 Sequences 487 S...

Page 18: ...Only 501 Mass Storage Remove Directory Remote Command Only 502 Sequences 502 Source Sequence 502 Analyzer Sequence 503 Source and Analyzer Sequence 503 Save As 503 Data Export 504 Amplitude Correction...

Page 19: ...dulation Setup 548 ARB 549 ARB 549 Select Waveform 550 ARB Setup 555 Trigger Type 560 Trigger Source 564 Trigger Initiate 565 Waveform Sequences 565 Waveform Utilities 576 Marker Utilities 586 Header...

Page 20: ...e Software Trigger Remote command Only 640 Query List Sequence Initiation Armed Status Remote Command Only 641 Source Preset 641 System 642 Trace Detector 643 Max Hold 643 Min Hold 643 User Preset 645...

Page 21: ...r and a signal source both of which interface with the front panel of the test set through an input output matrix and is run by its own instance of the XSA firmware application a fully loaded test set...

Page 22: ...applications C Program Files Agilent Licensing You may want to keep a copy of your license key in a secure location To do this you can print out a copy of the display showing the license numbers If y...

Page 23: ...do a software update To display a list of installed applications press System Show System Check the appropriate page of the Keysight web site for the latest available software versions according to t...

Page 24: ...find e6650a 2 The home page for your instrument appears in some cases you may see an initial splash screen containing a button named View the Webpage which you should click to display the home page 3...

Page 25: ...the chapter Front and Rear Panel Features of the document Latest available on line document E6650A Getting Started Guide Embedded PDF installed with the latest firmware revision If you are viewing thi...

Page 26: ...Panel Features of the document Latest available on line document E6640A Getting Started Guide Embedded PDF installed with the latest firmware revision If you are viewing this information as a Help fil...

Page 27: ...he chapter Front and Rear Panel Features of the document Latest available on line document E6650A Getting Started Guide Embedded PDF installed with the latest firmware revision If you are viewing this...

Page 28: ...it is the selected window is outlined in green Zoom is local to each Measurement Each Measurement remembers its Zoom state The Zoom state of each Measurement is part of the Mode s state Data acquisiti...

Page 29: ...at all window specific key presses apply only to that window You can tell which window is selected by the thick green border around it If a window is not selected its boundary is gray If a window in a...

Page 30: ...or instrument lacking a physical front panel display you can watch the instrument display via external monitor or remote desktop connection Right Click If you plug in a mouse and right click on the an...

Page 31: ...gged in or via Remote Desktop certain key codes on the PC keyboard map to front panel keys on the GPSA front panel These key codes are shown below Front panel key Key code Frequency CTRL SHIFT F Span...

Page 32: ...etup CTRL SHIFT E Meas Setup CTRL ALT E Trigger CTRL SHIFT T Sweep Control CTRL SHIFT W Restart CTRL ALT R Single CTRL ALT S Cont CTRL ALT C Zoom CTRL SHIFT Z Next Window CTRL SHIFT N Split Screen CTR...

Page 33: ...IFT F1 Menu key 2 CTRL SHIFT F2 Menu key 3 CTRL SHIFT F3 Menu key 4 CTRL SHIFT F4 Menu key 5 CTRL SHIFT F5 Menu key 6 CTRL SHIFT F6 Menu key 7 CTRL SHIFT F7 Backspace BACKSPACE Enter ENTER Tab Tab 1 1...

Page 34: ...1 About the Test Set Mouse and Keyboard Control 34 Sequence Analyzer User s Programmer s Reference...

Page 35: ...ned in the document Security Features and Document of Volatility This document is not included in the instrument on disk library but it may be downloaded from the Keysight web site To obtain a copy of...

Page 36: ...e transmitter without the need for call processing The flexibility of the list sequencers allows you to set up and make many complex measurements on defined sets of data using many different radio sta...

Page 37: ...mation about the programming documentation included with your product What Programming Information is Available on page 38 STATus Subsystem on page 56 Common Commands on page 85 Undefined variable Pri...

Page 38: ...e l The content in this manual is duplicated in the analyzer s Help the Help that you see for a key is identical to what you see in this manual Embedded Help in your instrument Describes all front pan...

Page 39: ...POWer 1 2 999 DEFine CALCulate FPOWer POWer 1 2 999 FETCh CALCulate FPOWer POWer 1 2 999 INITiate CALCulate FPOWer POWer 1 2 999 READ2 CALCulate FPOWer POWer 1 2 999 READ CALCulate FPOWer POWer 1 2 99...

Page 40: ...encer CONFigure LSEQuencer NDEFault DISPlay measurement ANNotation TITLe DATA string DISPlay measurement ANNotation TITLe DATA DISPlay ACTivefunc STATe ON OFF 1 0 DISPlay ACTivefunc STATe DISPlay ANNo...

Page 41: ...t 1 2 LISN PHASe INPut 1 2 LISN TYPE FOURphase ESH2Z5 ENV216 OFF INPut 1 2 LISN TYPE INPut MIXer EXTernal INTernal INPut MIXer INST NSEL 102 INST NSEL 105 INSTrument CATalog INSTrument COUPle DEFault...

Page 42: ...y STORe STATe 1 filename MMEM STOR SEQuences SLISt ALISt SAAList SSTep MySequence txt NOTE when theradiobandisNONE theseSCPIcommandsaretoconfigureFrequency otherwise thesecommandsaretoconfigurechannel...

Page 43: ...OUTPut RFIO3 RFIO4 SENSe LSEQuencer ABORt ERRor STATe ON OFF 1 0 SENSe LSEQuencer ABORt ERRor STATe SENSe LSEQuencer ABORt LIMit FAIL STATe ON OFF 1 0 SENSe LSEQuencer ABORt LIMit FAIL STATe SENSe LSE...

Page 44: ...set analysisInterval stepSeperation startPower powerStep measBitMap append SENSe LSEQuencer ACQuire 1 512 SETup AVERage NUMBer integer SENSe LSEQuencer ACQuire 1 512 SETup AVERage NUMBer SENSe LSEQuen...

Page 45: ...NSe LSEQuencer ACQuire 1 512 SETup TRIGger OUTPut NONE INTernal SENSe LSEQuencer ACQuire 1 512 SETup TRIGger OUTPut SENSe LSEQuencer ACQuire n CONFigure config_name SENSe LSEQuencer ACQuire n CONFigur...

Page 46: ...FILTer TYPE SENSe LSEQuencer CONFigure ADD WLAN configurationname SENSe LSEQuencer CONFigure CLEar SENSe LSEQuencer IF GAIN STATe LOW HIGH SENSe LSEQuencer IF GAIN STATe SENSe LSEQuencer INCLude SOURc...

Page 47: ...y SENSe LSEQuencer LIST SETup TRIGger INPut LEVel amp amp amp SENSe LSEQuencer LIST SETup TRIGger INPut LEVel SENSe LSEQuencer LIST SETup TRIGger OUTPut enum enum enum SENSe LSEQuencer LIST SETup TRIG...

Page 48: ...ce PRODuction LSEQuencer ADVanced WCDMa LBER PATTern filepath filename SERVice PRODuction LSEQuencer ADVanced WCDMa LBER PATTern LOAD SERVice PRODuction LSEQuencer ADVanced WCDMa LBER PATTern LOAD Str...

Page 49: ...IGger bool bool bool SOURce LIST SETup OUTPut TRIGger SOURce LIST SETup RADio BAND enum enum enum SOURce LIST SETup RADio BAND SOURce LIST SETup RADio BAND LINK enum enum enum SOURce LIST SETup RADio...

Page 50: ...DIX BANDX BANDXI BANDXII BANDXIII BANDXIV BANDXIX USCELL USPCS JAPAN KOREAN NMT IMT2K UPPER SECOND PAMR400 PAMR800 IMTEXT PCS1DOT9G AWS US2DOT5G PUBLIC LOWER NONE BAND1 BAND2 BAND3 BAND4 BAND5 BAND6 B...

Page 51: ...ve SOURce RADio ARB MPOLarity MARKer3 POSitive NEGative SOURce RADio ARB MPOLarity MARKer4 POSitive NEGative SOURce RADio ARB MPOLarity MARKer2 SOURce RADio ARB MPOLarity MARKer3 SOURce RADio ARB MPOL...

Page 52: ...ation PTRansition STATus PRESet STATus QUEStionable CALibration CONDition STATus QUEStionable CALibration ENABle integer STATus QUEStionable CALibration ENABle STATus QUEStionable CALibration EVENt ST...

Page 53: ...sition integer STATus QUEStionable TEMPerature PTRansition SYSTem APPLication CURRent NAME SYSTem APPLication CURRent OPTion SYSTem APPLication CURRent REVision SYSTem COMMunicate LAN SCPI HISLip ENAB...

Page 54: ...1 SYSTem MODule ENABle mnemonic SYSTem MODule INDex SYSTem MODule LIST SYSTem MODule MNEMonic SYSTem MODule MODel SYSTem MODule NAME SYSTem MODule SERial SYSTem OPTions SYSTem PDOWn NORMal FORCe SYST...

Page 55: ...Gger LSEQuencer EXTernal1 SLOPe TRIGger LSEQuencer EXTernal2 SLOPe TRIGger LSEQuencer SEQuence HOLDoff time TRIGger LSEQuencer SEQuence HOLDoff TYPE TRIGger LSEQuencer SEQuence HOLDoff TRIGger LSEQuen...

Page 56: ...are already running This is not true of status commands All the commands in the spectrum analyzer are assumed to be overlapped unless a command description specifically says that it is sequential What...

Page 57: ...are inputs to the STATus QUEStionable register 2 The summary output from the STATus QUEStionable register is an input to the Status Byte Register See the overall system in Figure at the beginning of...

Page 58: ...monitoring more than one device which supports SRQs you need to have the controller do something else while waiting you can t afford the performance penalty inherent to polling Use polling when your...

Page 59: ...tus Register Each bit in a register is represented by a numerical value based on its location See figure below This number is sent with the command to enable a particular bit If you want to enable mor...

Page 60: ...he condition 2 Determine how that bit reports to the request service RQS bit of the status byte 3 Send SCPI commands to enable the bit that monitors the condition and to enable the summary bits that r...

Page 61: ...requested service When you read the instrument s status byte register with a serial poll the RQS bit is reset to 0 Other bits in the register are not affected If the status register is configured to S...

Page 62: ...reset by a serial poll The same bit position MSS is read non destructively by the STB command If you serial poll bit 6 it is read as RQS but if you send STB it reads bit 6 as MSS For more information...

Page 63: ...is bit position indicates that the standard operation summary bit has been set The standard operation event register can then be read to determine the specific condition that caused this bit to be set...

Page 64: ...t The command SRE returns the decimal value of the sum of the bits previously enabled with the SRE integer command The service request enable register presets to zeros 0 Standard Event Status Register...

Page 65: ...y has been pressed This is true even if the instrument is in local lockout mode 7 A 1 in this bit position indicates that the instrument has been turned off and then on The standard event status regis...

Page 66: ...see the OPC command located in the IEEE Common Commands section Bit Condition Operation 0 Calibrating The instrument is busy executing its Align Now process 3 Sweeping The instrument is busy taking a...

Page 67: ...e commands used for querying or masking that particular register Numeric values for bit patterns can be entered using decimal or hexadecimal representations i e 0 to 32767 is equivalent to H0 to H7FFF...

Page 68: ...ial command Initial S W Revision Prior to A 02 00 Operation Event Query This query returns the decimal value of the sum of the bits in the Operation Event register The register requires that the assoc...

Page 69: ...All Remote Command STATus OPERation PTRansition integer STATus OPERation PTRansition Example STAT OPER PTR 1 Align Now operation beginning will be reported to the Status Byte Register Preset 32767 Min...

Page 70: ...ionable Status Summary bit bit3 in the Status Byte Register The variable integer is the sum of the decimal values of the bits you want to enable The preset condition is all bits in this enable registe...

Page 71: ...the corresponding bit in the Questionable Event register when the condition register bit has a negative transition 1 to 0 The variable integer is the sum of the decimal values of the bits that you wa...

Page 72: ...tion on page 73 Questionable Calibration Positive Transition on page 74 Questionable Calibration Condition This query returns the decimal value of the sum of the bits in the Questionable Calibration C...

Page 73: ...on register bit can set a bit in the event register The data in this register is latched until it is queried Once queried the register is cleared Mode All Remote Command STATus QUEStionable CALibratio...

Page 74: ...n Example STAT QUES CAL PTR 16384 Alignment is required Preset 32767 Min 0 Max 32767 Status Bits OPC dependencies Sequential command Initial S W Revision Prior to A 02 00 Questionable Calibration Skip...

Page 75: ...eset 0 Status Bits OPC dependencies Sequential command Initial S W Revision Prior to A 02 00 Questionable Frequency Enable This command determines which bits in the Questionable Frequency Condition Re...

Page 76: ...e Frequency Event register when the condition register bit has a negative transition 1 to 0 The variable integer is the sum of the decimal values of the bits that you want to enable Mode All Remote Co...

Page 77: ...rity Positive Transition on page 79 Questionable Integrity Condition This query returns the decimal value of the sum of the bits in the Questionable Integrity Condition register The data in this regis...

Page 78: ...il it is queried Once queried the register is cleared Mode All Remote Command STATus QUEStionable INTegrity EVENt Example STAT QUES INT Preset 0 Status Bits OPC dependencies Sequential command Initial...

Page 79: ...ition Example STAT QUES INT PTR 8 Measurement became uncalibrated Summary will be reported to the Integrity Summary of the Status Questionable register Preset 32767 Min 0 Max 32767 Status Bits OPC dep...

Page 80: ...STAT QUES POW COND Preset 0 Status Bits OPC dependencies Sequential command Initial S W Revision Prior to A 02 00 Questionable Power Enable This command determines which bits in the Questionable Power...

Page 81: ...ble Power Event register when the condition register bit has a negative transition 1 to 0 The variable integer is the sum of the decimal values of the bits that you want to enable Mode All Remote Comm...

Page 82: ...ture Positive Transition on page 84 Questionable Temperature Condition This query returns the decimal value of the sum of the bits in the Questionable Temperature Condition register The data in this r...

Page 83: ...until it is queried Once queried the register is cleared Mode All Remote Command STATus QUEStionable TEMPerature EVENt Example STAT QUES TEMP Preset 0 Status Bits OPC dependencies Sequential command...

Page 84: ...on register bit has a positive transition 0 to 1 The variable integer is the sum of the decimal values of the bits that you want to enable Mode All Remote Command STATus QUEStionable TEMPerature PTRan...

Page 85: ...the TRX and invoking the All alignment The instrument stops any measurement currently underway performs the alignment then restarts the measurement from the beginning similar to pressing the Restart k...

Page 86: ...Align Now All Key Path System Alignments Align Now Mode All Remote Command CALibration ALL CALibration ALL Example CAL Notes CALibration ALL returns 0 if successful CALibration ALL returns 1 if failed...

Page 87: ...ery until the bit is cleared 3 STATus QUEStionable CALibration CONDition Check if if there are any errors failures in previous calibration procedure Initial S W Revision X 14 20 Clear Status Clears th...

Page 88: ...command errors bits 2 and 5 ESE Returns a 36 indicating that the query and command status bits are enabled Notes For related commands see the STATus subsystem and SYSTem ERRor NEXT commands Preset 255...

Page 89: ...d either by polling the OPC bit in SER or by setting up the status system such that a service request SRQ is asserted when the OPC bit is set The OPC query returns a 1 after all the current overlapped...

Page 90: ...string of all the installed instrument options It is a comma separated list with quotes such as 503 P03 PFR To be IEEE compliant this command should return an arbitrary ascii variable that would not b...

Page 91: ...the mode to a consistent state with all of the default couplings set Backwards Compatibility Notes In legacy analyzers RST did not set the analyzer to Single but in the X Series it does for compliance...

Page 92: ...g its contents Remote Command STB Example STB Returns a decimal value for the bits in the status byte register For example if a 16 is returned it indicates that bit 5 is set and one of the conditions...

Page 93: ...o Continue This command causes the instrument to wait until all overlapped commands are completed before executing any additional commands There is no query form for the command Remote Command WAI Exa...

Page 94: ...2 Programming the Test Set Common Commands 94 Sequence Analyzer User s Programmer s Reference...

Page 95: ...3 Input Output Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 95...

Page 96: ...e first menu under the Input Output key Key Path Front panel key Remote Command SENSe FEED RF AIQ EMIXer SENSe FEED Example FEED RF FEED Couplings The SENSe FEED RF command turns the calibrator OFF Pr...

Page 97: ...settings are not part of each Mode s State they are saved in the Save State files so that all of the instrument settings can be recalled with Recall State as in legacy instruments Initial S W Revision...

Page 98: ...ut port RF coupling and current input impedance settings appear on this key as XX YY ZZ where XX is RF RF2 RFIO1 RFIO2 depending on what input is selected only appears on analyzers with multiple RF in...

Page 99: ...Remote Command SENSe FEED RF PORT INPut RFIN RFIN2 RFIO1 RFIO2 RFIO3 RFIO4 SENSe FEED RF PORT INPut Example FEED RF PORT RFIN Dependencies This key only appears in models that support multiple inputs...

Page 100: ...rt Example FEED RF PORT RFIO1 Dependencies RFIO1 is not available inE6607C If Multiport Adapter is ON Select RF Input to RFIO1 an error message is generated 221 Settings conflict RFIO1 or RFIO2 Port u...

Page 101: ...tablish a reference line to be used while building or editing a Corrections table The reference line is halfway up the display and represents 0 dB of correction It is labeled 0 dB CORREC It is drawn i...

Page 102: ...cted by the functions Key Path Input Output Corrections Mode SA I Q Analyzer Phase Noise VXA RTSA EMI Receiver DVB T H DTMB DVB T H DTMB W CDMA LTE LTE Adv FDD LTE LTE Adv TDD Sequence Analyzer BTooth...

Page 103: ...o OFF by Restore Input Output Defaults State Saved Saved in instrument state Backwards Compatibility Notes Unlike legacy analyzers Preset does not turn Corrections off Restore Input Output Defaults do...

Page 104: ...ors at the frequency of interest center frequency of each bucket are summed and added to the amplitude All trace operations and post processing treat this post summation value as the true signal to us...

Page 105: ...near scale like that of the spectrum analyzer this translates to If we interpolate on a linear scale we assume that the two points are connected by a straight line on the linear scale as below Sequenc...

Page 106: ...0 Modified at S W Revision A 14 00 Comment Sets an ASCII comment field which will be stored in an exported file Can be displayed in the active function area by selecting as the active function if desi...

Page 107: ...Properties RF Port Example CORR CSET RF PORT RFIN Dependencies Not available in E6607C ReadBack RF IN Initial S W Revision A 05 01 Modified at S W Revision A 14 00 RFOut The port that the current cor...

Page 108: ...nput Output Corrections Properties RF Port Example CORR CSET RF PORT RFIO1 ANAL Readback Correct Analyzer Correct Source and Analyzer Sets the corrections for the RFIO1 port to be applied to both the...

Page 109: ...mple CORR CSET RF PORT RFIO2 BOTH Readback Correct Source and Analyzer Edit Invokes the integrated editing facility for this correction set When entering the menu the editor window turns on the select...

Page 110: ...ing because its updates are tied to the sweep system Thus you should not try to use the editor in single sweep and it will be sluggish during compute intensive operations like narrow span FFT sweeps W...

Page 111: ...and the data in the row is displayed in light gray Key Path Input Output Corrections Edit Initial S W Revision A 02 00 Delete Point Deletes the currently selected point whether or not that point is be...

Page 112: ...ection CSET ALL STATe ON OFF 1 0 SENSe CORRection CSET ALL STATe Example SENS CORR CSET ALL OFF This command makes sure that no amplitude corrections are applied regardless of their individual on off...

Page 113: ...dB and 20 MHz 1 0 dB for correction set 1 Preset Empty after Restore Input Output Defaults Survives a shutdown or restart of analyzer application including a power cycle State Saved Saved in instrume...

Page 114: ...he External Ref Freq as set on the External Ref Freq softkey it will automatically switch to the external reference If it senses a 1 pulse per second signal it enters Pulse mode wherein the signal is...

Page 115: ...n external reference present the query returns EXTernal and not SENSe 3 If it was set to SENSe and there is a 1 pps signal present the query returns PULSe and not SENSe 4 If it was set to EXTernal the...

Page 116: ...o Calibrated on a System Restore Defaults Align or a System Restore Defaults All Readback Sense Initial S W Revision Prior to A 02 00 Modified at S W Revision A 14 00 Internal The internal reference i...

Page 117: ...rnal or Pulse selected to allow setup for when External is in use However the setting has no effect if the Internal Reference is in use Freq Ref In set to Internal Pulse or SENSE INT or SENSE PULSE Pr...

Page 118: ...for the current output Key Path Input Output RF Output Test Set Config RF Output Example FEED RF PORT OUTP RFO Notes If RF Output is selected as RF Output Port you need to choose the settings in the...

Page 119: ...T INPut RFIO3 RFIO4 Example HDUPlex PORT INPut RFIO3 HDUPlex PORT INPut Dependencies If RFIO3 is selected as RF Output then RF Input will be set to RFIO4 automatically And if RFIO4 is selected as RF O...

Page 120: ...t Output Output Config Remote Command TRIGger TRIGger1 TRIGger2 SEQuence OUTPut HSWP MEASuring MAIN GATE GTRigger OEVen SPOint SSWeep SSETtled S1Marker S2Marker S3Marker S4Marker OFF TRIGger TRIGger1...

Page 121: ...t to the Trig 1 Out or Trig 2 Out connector Key Path Input Output Output Config Trig 1 2 Output Example TRIG1 OUTP OFF Readback Off Initial S W Revision Prior to A 02 00 Sweeping HSWP Selects the Swee...

Page 122: ...0 Gate Selects the gate signal to be output to the Trig 1 Out or Trig 2 Out connector The gate signal has been delayed and its length determined by delay and length settings When the polarity is posit...

Page 123: ...e Trig 2 Out key is blanked and sending the SCPI command for this output generates an error Hardware missing Not available for this model number In models that do not support the Trigger 2 output this...

Page 124: ...rm file Key Path Input Output Output Config Trig 1 2 Output Example TRIG1 OUTP S3M ReadBack Marker 3 Initial S W Revision A 05 01 Source Marker 4 Trigger output at marker 4 in current playing Waveform...

Page 125: ...al S W Revision A 04 00 More Information The table below gives the range for each output Analog Out Nominal Range exc 10 overrange Scale Factor Notes Off 0 V Screen Video 0 1 V open circuit 10 divisio...

Page 126: ...IO board is installed This is a remote query command only V network Remote Command Only Enables you to select the V network that is controlled via the AUX IO port Remote Command INPut 1 2 LISN TYPE F...

Page 127: ...the V network Remote Command INPut 1 2 LISN FILTer HPAS STATe ON OFF INPut 1 2 LISN FILTer HPAS STATe Example INP LISN FILT HPAS ON Dependencies Only available for ENV216 V network This key is grayed...

Page 128: ...enerated as part of a 221 Settings conflict LISN function not available warning Preset Set to GRO on a Restore Input Output Defaults State Saved Saved in instrument state Range GRO FLO Initial S W Rev...

Page 129: ...4 Mode Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 129...

Page 130: ...V LTE LTETDD LTEAFDD LTEATDD MSR DVB DTMB DCTV ISDBT CMMB WLAN CWLAN CWIMAXOFDM WIMAXFIXED IDEN RLC SCPILC VSA89601 INSTrument SELect Example INST SA Notes The available parameters are dependent upon...

Page 131: ...to memory is selected by either pressing that applications Mode key or sending that applications INST SEL command over SCPI there will be a pause while the Application is loaded During this pause a me...

Page 132: ...aces and results If you attempt to load a mode via SCPI that will exceed memory capacity the Mode does not load and an error message is returned 225 Out of memory Insufficient resources to load Mode m...

Page 133: ...of AM FM and phase modulated signals If you are using the Help feature this mode must be currently active to access its detailed information If it is not active exit the Help feature Esc key select t...

Page 134: ...detailed information If it is not active exit the Help feature Esc key select the mode and re access Help Key Path Mode Example INST SEL LTEAFDD INST NSEL 107 Notes When the N9080A 80B 1FP exists the...

Page 135: ...rder is not changed by the Configure Applications utility found in the System Power On menu See Detailed List of Modes on page 138 for Mode details The Mode Number is the parameter for use with the IN...

Page 136: ...PNOISE WCDMA Backwards Compatibil ity Notes VSA E4406A INSTrument CATalog returned a list of installed INSTrument SELECT items as a comma separated list of string values BASIC GSM EDGEGSM CDMA NADC P...

Page 137: ...maximum of 23 characters each numeral can be an integer 3 decimal points Preset Not affected by a Preset State Saved Not saved in state the value will be the selected application when a Save is done...

Page 138: ...it the Help feature Esc key select the mode and re access Help Key Path Mode Example INST SEL CDMA1XEV INST NSEL 15 Initial S W Revision Prior to A 02 00 802 16 OFDMA WiMAX WiBro Selects the OFDMA mod...

Page 139: ...ndard There are several measurements available in this mode If you are using the Help feature this mode must be currently active to access its detailed information If it is not active exit the Help fe...

Page 140: ...l S W Revision Prior to A 02 00 LTE Selects the LTE mode for general purpose measurements of signals following the LTE FDD standard There are several measurements available in this mode If you are usi...

Page 141: ...E INST NSEL 102 Initial S W Revision A 14 00 Modified at S W Revision A 14 50 LTE Advanced TDD As LTE Advanced TDD and LTE TDD modes are converged into one single application the single softkey under...

Page 142: ...e in this mode If you are using the Help feature this mode must be currently active to access its detailed information If it is not active exit the Help feature Esc key select the mode and re access H...

Page 143: ...rom then on all modes that support global settings use the Global Center Frequency So you can switch between any of these modes and the Center Freq will remain unchanged Adjusting the Center Freq of a...

Page 144: ...o A 02 00 Restore Defaults This key resets all of the functions in the Global Settings menu to Off This also occurs when System Restore Defaults All Modes is pressed Key Path Mode Setup Global Setting...

Page 145: ...5 System Functions Undefined variable Primary ProductName Sequence Analyzer User s Programmer s Reference 145...

Page 146: ...er The File Explorer is a separate Windows application so to return to the analyzer once you are in the File Explorer you may either Exit the File Explorer by clicking on the red X in the upper right...

Page 147: ...n which causes the analyzer display to fill the screen Once the application is maximized this key is replaced by the Restore Down key Key Path File Mode All Notes No equivalent remote command for this...

Page 148: ...isplay System Display Settings Theme The Theme control has a corresponding SCPI command Parameter Name Print Themes Parameter Type Enum Mode All Remote Command SYSTem PRINt THEMe TDColor TDMonochrome...

Page 149: ...wn This key allows you to Restore Down the Instrument Application and reverses the action taken by Maximize This key is only visible when the application has been maximized and after the Restore Down...

Page 150: ...n A dialog box is used to confirm that you intended to exit the application Key Path File Mode All Notes The Instrument Application willclose No further SCPI commands can be sent Use with caution Init...

Page 151: ...is already in progress Sending HCOPy ABORt will cause the analyzer to stop sending data to the printer although the printer may continue or even complete the print depending on how much data was sent...

Page 152: ...he list of errors displayed in the Errors screen does not automatically refresh You must press the Refresh key or leave the screen and return to it to refresh it History brings up a screen displaying...

Page 153: ...e or Status lines and are logged to the event queue They never appear as text in the graticule area as they sometimes do in previous analyzers and they are never displayed in the settings panel at the...

Page 154: ...onal information is returned when you send the SYSTem ERRor query The additional information consists of the characters that stimulated the error This can aid you in debugging your test programs by in...

Page 155: ...urrent status conditions Mode Preset does not clear the error queue Restore System Defaults will clear all error queues CLS only clears the queue if it is sent remotely and RST does not affect any err...

Page 156: ...1 OFF ON Example SYST ERR OVER 1 Enable overload errors Preset Set to OFF by Restore Misc Defaults no Overload errors go to SCPI State Saved Saved in instrument state Initial S W Revision A 10 01 Powe...

Page 157: ...or to A 02 00 Show System contents Remote Command Only A remote command is available to obtain the contents of the Show System screen the entire contents not just the currently displayed page Remote C...

Page 158: ...The screen is formatted into two groupings product descriptive information and hardware information The hardware information is listed in a table format The Previous Page is grayed out if the first p...

Page 159: ...nd all data will be lost List installed Options Remote Command Only Lists the installed options that pertain to the instrument signal analyzer Mode All Remote Command SYSTem OPTions Example SYST OPT N...

Page 160: ...Command SYSTem HELP HEADers Example SYST HELP HEAD Notes The output is an IEEE Block format with each command separated with the New Line character hex 0x0A Initial S W Revision Prior to A 02 00 SCPI...

Page 161: ...f the hour in 24 hour format minute is the two digit representation of minute second is the two digit representation of second Unless the current account has Power User or Administrator privileges an...

Page 162: ...will return the mnemonic of the instance as used in the command line Process mnemonic argument Mode All Remote Command SYSTem MODule MNEMonic Example SYST MOD MNEM Notes This will return the mnemonic...

Page 163: ...ENAB mnemonic returns 0 for disabled 1 for enabled The command SYST MOD ENAB mnemonic 0 1 will disable enable the configuration Notes Enabling a configuration that does not have a HW will result in r...

Page 164: ...default command on it will enable this confutation Example SCPI syst mod def TRX1 SCPI syst mod enab TRX2 0 SCPI syst mod enab TRX2 0 SCPI syst mod def TRX2 SCPI syst mod enab TRX2 1 SCPI syst mod def...

Page 165: ...14 14 Power On Enables you to select how the instrument should power on The options are Mode and Input Output Defaults User Preset and Last State Key Path System Mode All Remote Command SYSTem PON TYP...

Page 166: ...ower up for the first time in User Preset Key Path System Power On Mode All Example SYST PON TYPE USER Readback Text User Preset Backwards Compatibility Notes Power On User Preset will cause the instr...

Page 167: ...State Backwards Compatibility Notes It is no longer possible to power up the analyzer in the last mode the analyzer was running with that mode in the preset state ESA PSA SYST PRESET TYPE MODE with SY...

Page 168: ...an application will cause it to be loaded into the analyzer s memory when the analyzer program starts up If you do this the delay will increase the time it takes to start up the analyzer program but t...

Page 169: ...cations you have selected cannot all fit into the analyzer s memory You must deselect applications until the fuel bar turns yellow YELLOW the applications you have selected can all fit into the analyz...

Page 170: ...ication in the list Key Path System Power On Configure Applications Initial S W Revision A 02 00 Save Changes and Exit Applies the configuration of the applications list The marked applications will b...

Page 171: ...y will exit the Configure Applications utility without saving your changes Key Path System Power On Configure Applications Initial S W Revision A 02 00 Modified at S W Revision A 04 00 Restore Power O...

Page 172: ...cations you want to load into the instrument memory or query the Virtual Memory utilization for your applications Configuration list Remote Command Only on page 172 Configuration Memory Available Remo...

Page 173: ...Remote Command Only This remote command is a query of the amount of Virtual Memory used by all measurement applications Remote Command SYSTem PON APPLication VMEMory USED Example SYST PON APPL VMEM US...

Page 174: ...e and 4 a 45 minute warm up period between power up of the TRX and invoking the All alignment The instrument stops any measurement currently underway performs the alignment then restarts the measureme...

Page 175: ...All Key Path System Alignments Align Now Mode All Remote Command CALibration ALL CALibration ALL Example CAL Notes CALibration ALL returns 0 if successful CALibration ALL returns 1 if failed CALibrat...

Page 176: ...if if there are any errors failures in previous calibration procedure Initial S W Revision X 14 20 All but RF Immediately executes an alignment of all subsystems except the RF subsystem which includes...

Page 177: ...r bit 0 in the Status Operation register This command is sequential it must complete before further SCPI commands are processed Interrupting the alignment from remote is accomplished by invoking Devic...

Page 178: ...estionable Calibration register The query form of the remote commands CALibration RF will invoke the alignment of the RF subsystem and return a success or failure value An interfering user signal is g...

Page 179: ...NPEN Notes CALibration RF NPENding is the same as CALibration RF including all conditions status register bits except that this scpi command does not BLOCK the scpi session so the user should use stat...

Page 180: ...libration 2 STATus OPERation CONDition Check if the calibration is completed or not If bit 0 is set then the system is doing calibration the user should repeat this scpi query until the bit is cleared...

Page 181: ...lignment from remote is accomplished by invoking Device Clear followed by the ABORt command Successful completion will clear bit 14 in the Status Questionable Calibration register Preset Not affected...

Page 182: ...st Align RF temperature to the current temperature and reset the Last Align RF time A successful Align Now All or Align Now All but RF will set the Last Align Now All temperature to the current temper...

Page 183: ...ALL Example CAL TIME LALL Notes Value is the elapsed time in seconds since the last successful Align Now All or Align Now All but RF was executed State Saved No Initial S W Revision Prior to A 02 00 K...

Page 184: ...ial S W Revision Prior to A 02 00 Key Path SCPI Only Mode All Remote Command CALibration TIME LIF Example CAL TIME LIF Notes Value is the elapsed time in seconds since the last successful Align IF was...

Page 185: ...rmal will be executed sequentially thus OPC or WAI will wait until the alignment processing is complete Initial S W Revision Prior to A 02 00 Execute Expired Alignments Remote Command Only Alignments...

Page 186: ...g the telnet socket and or SICL capability Key Path System I O Config Initial S W Revision Prior to A 02 00 SCPI Telnet Turns the SCPI LAN telnet capability On or Off allowing you to limit SCPI access...

Page 187: ...dress of your analyzer inst0 Instrument Logical Unit The unique integer assigned to your analyzer when using SICL LAN 8 Emulated GPIB Name The name same as the remote SICL address of the device used w...

Page 188: ...th a Restore System Defaults Misc State Saved No Range On Off Initial S W Revision A 11 00 SCPI Socket Control Port Remote Command Only Returns the TCP IP port number of the control socket associated...

Page 189: ...restart of the software and therefore survives a power cycle Preset This is unaffected by Preset but is set to Factory on a Restore System Defaults Misc State Saved No Initial S W Revision A 06 00 Mod...

Page 190: ...rt of the software and therefore survives a power cycle Null string as parameter restores the Factory setting example SYST IDN Preset This is unaffected by Preset but is set to the original factory se...

Page 191: ...mode switch Confirmation is required to restore the Input Output setting The confirmation dialog is Key Path System Restore System Defaults Example SYST DEF INP Initial S W Revision Prior to A 02 00...

Page 192: ...level of Restore System Defaults does not affect any other system settings mode settings and does not cause a mode switch After performing this function it may impact the auto alignment time of the i...

Page 193: ...other Restore System Defaults groups The following table is a complete list of settings associated with this group Miscellaneous Setting Default Value Verbose SCPI Off The SYST PRES TYPE MODE Auto Fil...

Page 194: ...o restore the factory default values The confirmation dialog is Key Path System Restore System Defaults Example SYST DEF MOD Couplings An All Mode will cause the currently running measurement to be ab...

Page 195: ...modes to a consistent state so it is unnecessary to couple any settings Initial S W Revision Prior to A 02 00 Modified at S W Revision A 14 00 Control Panel Opens the Windows Control Panel The Contro...

Page 196: ...n Prior to A 02 00 Licensing Opens the license explorer This feature is not available if option SF1 is installed For Help on this key select Help in the menu bar at the top of the license explorer win...

Page 197: ...compatibility Initial S W Revision Prior to A 02 00 Remote Comman d SYSTem LKEY DELete OptionInfo LicenseInfo Example SYST LKEY DEL N9073A 1FP 027253AD27F83CDA5673A9BA5F427FDA5E4F25AEB1017638211AC9F60...

Page 198: ...ionInfo Example SYST LKEY N9073A 1FP Notes The OptionInfo contains the feature and the version You must specify the feature but can omit the version If you omit the version the system regards it as th...

Page 199: ...ncluding the internal USB memory used for a back up location for the calibration data Dependencies This key is grayed out unless the current user has administrator privileges Preset This is unaffected...

Page 200: ...the instrument has been powered on odometer The display should appear listing the statistics product number serial number and firmware revision The CXA models in which the AC DC Switch field is called...

Page 201: ...dvanced diagnostic capabilities performed in the factory or under instructions from repair procedures This menu key is only visible when the logged in user is saservice This feature is not available i...

Page 202: ...startup of the key recorder is controlled by a registry entry refer to the key recorder document listed above Preset Not affected by Preset State Saved No Range On Off Initial S W Revision Prior to A...

Page 203: ...once you have the fully qualified the path and file name If the self test fails the following error message will be generated 330 Self test failed see log file E Agilent Instrument FECTestLog txt If...

Page 204: ...437 Instrument S W 11 16 2012 2 51 19 PM FpgaVersionTest Date Time GMT Name MeasValue ValidRange Result 11 23 2012 16 13 56 Analog_FPGA 16 000 16 000 Pass 11 23 2012 16 13 56 Digital_FPGA 50 000 46 00...

Page 205: ...tial S W Revision A 12 50 Keysight Converged PSA IP Address SYSTem COMMunicate LAN ADDRess string SYSTem COMMunicate LAN ADDRess SYSTem COMMunicate LAN SELF IP string SYSTem COMMunicate LAN SELF IP Ga...

Page 206: ...5 System Functions System 206 Sequence Analyzer User s Programmer s Reference...

Page 207: ...e allows you to test the radio characteristics of a mobile device that uses multiple radio standards A Sequence that you set up in the List Sequencer comprises multiple radio standards for user define...

Page 208: ...DEFault INITiate LSEQuencer FETCh LSEQuencer 1 2 3 READ LSEQuencer 1 2 3 MEASure LSEQuencer 1 2 3 CONFigure LSEQuencer NDEFault stops the current measurement and changes to the specified measurement I...

Page 209: ...value for 1st measurement in Analysis Interval 1 10 Number of results in first measurement in Analysis Interval 1 11 Measurement results for first measurement in Analysis Interval 1 12 Integrity value...

Page 210: ...anually then results return 1 Mode Sequence Analyzer 3 Returns three integer numbers Acquisition number followed by Analysis Interval Number followed by the Meas Bitmap Number of first detected positi...

Page 211: ...Interval 1 12 Measurement results for 2nd measurement in Analysis Interval 1 13 repeat 10 to 12 for all other measurements in Analysis Interval 1 14 Summary Integrity value for Analysis Interval 2 15...

Page 212: ...l average count should be equal to the Avg Number on page 385 if Ignore Error In Average on page 295 is OFF and might be less than or equal to the user setting Avg Number on page 385 when Ignore Error...

Page 213: ...e capability to indicate if the sequence has finished its initialization It won t return until the instrument is ready to perform capture The MEASure query MEAS LSEQ1 2 3 presets the test set to thede...

Page 214: ...6 List Sequence Measurements File File See File on page 146 214 Sequence Analyzer User s Programmer s Reference...

Page 215: ...6 List Sequence Measurements Input Output Input Output See Input Output on page 96 Sequence Analyzer User s Programmer s Reference 215...

Page 216: ...arker is affected by the functions parameter_ table_ 23 52941 52 94118 Key Path Marker Notes The selected marker is remembered even when not in the Marker menu and is used if a Search is done or a Ban...

Page 217: ...lue Its absolute Y Axis value is then the value of the trace point at that X Axis value parameter_table_23 52941 52 94118 Key Path Marker Example CALC LSEQ MARK MODE POS Notes See the description unde...

Page 218: ...saved in instrument state Initial S W Revision A 05 00 Help Map ID 35249 Properties Opens a menu used to set certain properties of the selected marker parameter_table_23 52941 52 94118 Key Path Marke...

Page 219: ...fault Relative To marker reference marker is the next higher numbered marker current marker 1 For example if marker 2 is selected then its default reference marker is marker 3 The exception is marker...

Page 220: ...ffix is sent that does not match the current marker X axis scale unit an error Invalid suffix is generated The query returns the marker s absolute X axis value if the control mode is Normal or the off...

Page 221: ...OFF so Marker X axis Value query returns a not a number NAN Min 0 Max 19999 Initial S W Revision A 05 00 Help Map ID 35254 Marker Y axis Value Remote Command Only The command below selects the marker...

Page 222: ...e fundamental x axis units of the trace that marker is on and the X Axis value of the marker being moved in the same fundamental x axis units parameter_table_23 52941 52 94118 Key Path Marker Remote C...

Page 223: ...ted marker on the trace point with the maximum y axis value for that marker s trace parameter_table_23 52941 52 94118 Remote Command CALCulate LSEQuencer MARKer 1 2 12 MAXimum Example CALC LSEQ MARK2...

Page 224: ...re LSEQuencer CONFigure LSEQuencer NDEFault INITiate LSEQuencer FETCh LSEQuencer 1 2 3 READ LSEQuencer 1 2 3 MEASure LSEQuencer 1 2 3 CONFigure LSEQuencer NDEFault stops the current measurement and ch...

Page 225: ...epeat 5 to 25 for Acq 2 and for all subsequent Acq s in the Sequence The format of the results for each measurement is detailed in the following sections Each measurement returns all results when quer...

Page 226: ...is one 2 Reserved for Keysight use 3 Summary Integrity value for the specified acquisition 4 Number of Analysis Steps in the specified acquisition 5 Summary Integrity value for Analysis interval 1 6 A...

Page 227: ...t results for 2nd measurement in Analysis Interval 11 repeat 8 to 10 for all other measurements in Analysis Interval The entire Sequence results can still be queried using the FETC LSEQ1 detailed abov...

Page 228: ...mmand provides the capability to indicate if the sequence has finished its initialization It won t return until the instrument is ready to perform capture The MEASure query MEAS LSEQ1 2 3 presets the...

Page 229: ...CDMA Mod Acc in Analysis Interval 2 24 24 values Measurement results for W CDMA Mod Acc in Analysis Interval 2 1 value Summary Integrity value for Acquisition 2 1 value Number of Analysis Steps in Ac...

Page 230: ...the results for the interval are preceded by a value of 2049 the decimal weight of bit 11 plus bit 0 in the meas bitmap the results for Tx Power are preceded by a value of 4 because that measurement...

Page 231: ...are returned in ascending order of their meas bitmap values Number Of Results is a floating point number which appears ahead of the results of a measurement within the analysis interval it represents...

Page 232: ...t selected are normal and other measurements selectable Number Of Results is a floating point number which appears ahead of the results of a measurement within the analysis interval it represents the...

Page 233: ...umber which appears ahead of the results for the analysis interval it is a decimal representation of the meas bitmap value for the measurements included in the interval The value returned for PVT resu...

Page 234: ...pe the returned value is 999 0 In multi slot condition the returned value is the detected TSC of the specified slot Time Slot ON or the first evaluated slot Time Slot OFF Note The returned value in Sy...

Page 235: ...nts and the results are returned in ascending order of their meas bitmap values Number Of Results is a floating point number which appears ahead of the results of a measurement within the analysis int...

Page 236: ...dBm 13 Minimum Power Result is the minimum peak level in the range specified by Analysis Time Slot and Measured Time Slots in dBm 14 Actual Sample Interval Result is a floating point number representi...

Page 237: ...p then the value returned represents the combined meas bitmap value for all included measurements and the results are returned in ascending order of their meas bitmap values Number Of Results is a flo...

Page 238: ...Quencer l ACQuire m ASTep n TDPVt TRACe Only up to 2000 envelop trace points can be returned So the envelop trace returned may be decimated If average is on and average number is N this result is calc...

Page 239: ...ectrum measurement used in the GSM mode is used in the sequencer to return results for both GMSK and EDGE modulated signals If the analysis step has requested this measurement then the results returne...

Page 240: ...4 switching transients measurement values and so on 2 Returns a list of relative level to the test limit the relative test limit and the absolute test limit for all the offset frequencies The relative...

Page 241: ...eturned for PFER results is 64 If more than one measurement is included in this analysis step then the value returned represents the combined meas bitmap value for all included measurements and the re...

Page 242: ...between the measured phase trajectory and the reference phase trajectory 11 Maximum Frequency Error A floating point number in Hz of the peak frequency error through over the measurement area Take th...

Page 243: ...e TDSCDMA mode is used in the Sequencer to return results for TDSCDMA modulated signals The traces captured in primary acquisition and range extension acquisition are merged first If averaging is on a...

Page 244: ...ults 4 Rump up time is the time difference between 10 and 90 voltage points relative to peak on the positive slope of the burst here burst has the same meaning in Burst width If averaging is on and av...

Page 245: ...ff power after is the averaged power between the 860th chips to the end of the analysis interval This result is derived from the 8960 Tdscdma Transmit ON OFF Power result Range 3 OFF Power which is th...

Page 246: ...30719 66 92811 Index Result Details 0 Pass fail results 1 Overall Pass Fail Then returns 24 scalar values of the pass fail 0 0 pass 1 0 fail determined by testing the relative to the reference carrie...

Page 247: ...elative power 46 Lower offset F absolute power 47 Upper offset F relative power 48 Upper offset F absolute power If Meas Type is Total Power Reference these results are returned in units of dBm If Mea...

Page 248: ...esults 1 Absolute power at centre frequency reference area dBm 2 Peak frequency in the centre frequency reference area Hz 3 Relative integrated power on the negative offset A dBc 4 Absolute integrated...

Page 249: ...ep 1 1000 WLAN SEM TRACe Or Async fetch FETCh LSEQuencer ASYNc ACQuire 1 512 ASTep 1 1000 WLAN SEM TRACe These scpi commands are only available when WLAN SEM measurement is configured in the specified...

Page 250: ...tion Accuracy Rho measurement used in the WCDMA LTE FDD TD SCDMA LTE TDD and modes can be used in the sequencer If the analysis step has requested this measurement then the results returned for the an...

Page 251: ...ass 4 Rho pass fail result 1 0 fail 0 0 pass 5 Peak Code Domain Error pass fail result 1 0 fail 0 0 pass 6 RMS EVM Average is a floating point number in percent of EVM over the entire measurement area...

Page 252: ...hen the Sync Type is not PRACH Message the returned value is NAN 21 Average Peak EVM Average Peak is a floating point number in percent of the averaging for Peak EVM readings on each slot over the ent...

Page 253: ...represents the combined meas bitmap value for all included measurements and the results are returned in ascending order of their meas bitmap values Number Of Results is a floating point number which a...

Page 254: ...n Accuracy Spectrum Flatness Results are detailed here These results are part of LTE FDD Modulation Accuracy measurement and they can be querried by MEAS READ FETCh LSEQuencer ACQuire 1 512 ASTep 1 10...

Page 255: ...sults LTE FDD Modulation Accuracy Spectrum Flatness Ripple Results are detailed here These results are part of LTE FDD Modulation Accuracy measurement and they can be queried by MEAS READ FETCh LSEQue...

Page 256: ...r Or Async fetch FETCh LSEQuencer ASYNc ACQuire 1 512 ASTep 1 1000 IEMission POWer qonly This scpi command only available when LTE FDD Modulation Accuracy measurement is configured in the specified an...

Page 257: ...n the inband emission limit mask and actual measured power per non allocated RB Which means the margin Limit Power in dB and a negative margin stands for the power exceeds the limit 0 1 Minimal Inband...

Page 258: ...ead of the results of a measurement within the analysis interval it represents the number of results metrics returned by the measurement The value returned for TD SCDMA Modulation Accuracy results is...

Page 259: ...ot 18 Peak Code Domain Error Code Length Peak Hold is the code length of peak hold Peak CDE in average cycle of the selected timeslot 19 Peak Code Domain Error Code Index Peak Hold is the code index o...

Page 260: ...returned for WLAN Modulation Accuracy results is 19 WLAN Modulation Accuracy measurement returns the following comma separated scalar results non_parameter_table_15 52288 51 47059 Index Result Paramet...

Page 261: ...imal representation of the meas bitmap value for the measurements included in the interval The value returned for WLAN MIMO Modulation Accuracy results is 262144 If more than one measurement is includ...

Page 262: ...1 0 Not tested 14 Stream 3 RMS EVM dB 15 Stream 3 Peak EVM dB 16 Stream 3 Pilot EVM dB 17 Stream 3 Data EVM dB 18 Stream 3 Chips Peak EVM 19 Reserved 20 Reserved 21 Reserved 22 Reserved 23 Reserved 2...

Page 263: ...hannel 2 IQ Gain Imblance dB 52 Channel 2 IQ Offset dB 53 Channel 2 IQ Quadrature Error deg 54 Channel 2 IQ Timing Skew pps 55 Channel 2 Cross Power dB 56 Channel 2 Sync Corr 57 Channel 3 RMS EVM pass...

Page 264: ...e SCPI only header values are as follows Meas Bitmap Header is a floating point number which appears ahead of the results for the analysis interval it is a decimal representation of the meas bitmap va...

Page 265: ...oup If averaging is off then it returns result for the measurement interval 11 Magnitude Error is a floating point number in percent of averaged magnitude error over the entire measurement interval 12...

Page 266: ...s a decimal representation of the meas bitmap value for the measurements included in the interval The value returned for WCDMA CDP results is 8192 If more than one measurement is included in this anal...

Page 267: ...ode Length Vector is less than the max spreading code length 16 the power is duplicated 16 spreading code length times Its data are lined according to the increasing code index 1 Normalized Code Domai...

Page 268: ...eturned via SCPI The front panel user interface does not return the integrity values non_parameter_table_ 6 32353 16 19281 12 9085 42 81046 Bit Error Description Level This maps to Status Sub system b...

Page 269: ...Path Meas Initial S W Revision A 05 00 Help Map ID 0 Remote Measurement Functions This section contains the following topics Measurement Group of Commands on page 270 Current Measurement Query Remote...

Page 270: ...lected trace data results will be returned See each command for details of what types of scalar results or trace data results are available ASCII is the default format for the data output Older versio...

Page 271: ...d If you need to get new measurement data use the READ command which is equivalent to an INITiate followed by a FETCh The scalar measurement results will be returned if the optional n value is not inc...

Page 272: ...calar measurement results will be returned If the n value is set to a value other than 1 the selected trace data results will be returned See each command for details of what types of scalar results o...

Page 273: ...rally advisable to be in Single Sweep or Update Off This command is used to compress or decimate a long trace to extract and return only the desired data A typical example would be to acquire N frames...

Page 274: ...airs is returned MAXimum returns the maximum data point y value for the specified region s of trace data For I Q trace data the maximum magnitude of the I Q pairs is returned MEAN returns a single val...

Page 275: ...f data points in the specified region s Equation 5 RMS Value of I Q Data Pairs for Specified Region s where Xi is the complex value representation of an I Q pair Xi its conjugate complex number and n...

Page 276: ...0 in Waveform time domain measurement and all parameters are specified by data point in PPHase The rms power of the specified region may be expressed as Power 10 x log 10 x RMS I Q value 10 The RMS I...

Page 277: ...It defines how much data will be compressed into one value This parameter has a default value equal to the current trace length roffset repeat offset is an optional real number It is in seconds for ti...

Page 278: ...ude FREQuency TIME Example Example for Swept SA measurement in Spectrum Analyzer Mode CALC DATA4 PEAK 40 10 FREQ GTDL This will identify the peaks of trace 4 that are above 40 dBm with excursions of a...

Page 279: ...this by peforming real time overlapped FFTs at the hardware layer using software for basic post processing before returning the result to the user The upshot of this approach is improved throughput fo...

Page 280: ...defined in the configuration string Initial S W Revision A 14 00 Acquisition Time Example CALC FPOW POW1 DEF AcquisitionTime 0 002 Notes The acquisition time parameter sets the time in which the entir...

Page 281: ...analyzer is subtracted from all measurements This effectively lowers the noise floor of the analyzer When noise correction is enabled the first measurement for a given set of input parameters will ta...

Page 282: ...method Because two acquisitions rather than a single acquisition are made when spur suppression is enabled the measurement time will always be slower when spur suppression is enabled Preset False Ran...

Page 283: ...ifferent IF paths For example if the signal is less than 25 MHz wide then the user can select the B25M path to take advantage of additional filtering on this analog IF path Preset B40M Range B10M B25M...

Page 284: ...Off Range Off Low Full Initial S W Revision A 14 00 Resolution Bandwidth Mode Example CALC FPOW POW1 DEF PreAmpMode Low Notes The resolution bandwidth mode parameter allows the user to choose whether...

Page 285: ...itial S W Revision A 14 00 Trigger Level Example CALC FPOW POW1 DEF TriggerLevel 2 Notes The trigger level parameter sets the voltage value at which an external trigger is detected Preset 1 2 V Range...

Page 286: ...ge 0 1 s Default Unit Seconds Initial S W Revision A 14 00 Signal Input Example CALC FPOW POW1 DEF SignalInput Fp50MHzCW Notes The signal input parameter allows the user to select between using the ma...

Page 287: ...e integration bandwidth filter weighs all frequencies within the bandwidth equally The root raised cosine filter has an associated shape parameter defined by the FilterAlpha parameter All array parame...

Page 288: ...th The bandwidth at which 99 of the total power resides within the channel Hz percentage configurable using OccupiedBandwidthPercent parameter All array parameters should have the same number of eleme...

Page 289: ...02 3 01 1 0 Notes This parameter only applies for channels whose Function is set to XdBBandwidth The X dB bandwidth parameter is used to specify the power relative to the peak channel power over which...

Page 290: ...h 1000000 OffsetFrequency 0 Function BandPower FilterType IBW FilterAlpha 0 22 OccupiedBandwidthPercent 0 99 XdBBandwidth 3 01 DoNoiseCorrection False DoSpurSuppression False MeasurementMethod Hardwar...

Page 291: ...ALC FPOW POW1 FETC Notes Option FP2 is required Returns m comma separated ASCII values where m corresponds to the number of bandwidths defined 1 Declared function return in the 1st specified channel 2...

Page 292: ...NIT command immediately followed by a FETC command The returned results are in a binary format This command is used primarily for diagnostic purposes to test for ADC overloads and to visibly inspect t...

Page 293: ...alyzer n commands and queries Remote Command FORMat TRACe DATA ASCii INTeger 32 REAL 32 REAL 64 FORMat TRACe DATA Notes The query response is ASCii ASC 8 REAL 32 REAL 32 REAL 64 REAL 64 INTeger 32 INT...

Page 294: ...the current Y Axis Unit in a definite length block Format Data Byte Order Remote Command Only This command selects the binary data byte order for data transfer and other queries It controls whether bi...

Page 295: ...obiles in other cells when needed for handovers 26 frames last 120 msec So the DUT has 2 Idle Slot on Frame 12 and Frame 25 The GSM EDGE related measurements will report errors when performing calcula...

Page 296: ...PVT measurement has a fixed number of 12 offset time points for the burst captured by the List Sequencer The offset times are referenced to the centre of symbol 0 for that burst the start of the usef...

Page 297: ...Vanced LTE CCONdition NORMal EXTReme SERVice PRODuction LSEQuencer ADVanced LTE CCONdition Example SERV LSEQ ADV LTE CCON EXTR SERV LSEQ ADV LTE CCON Preset NORMal State Saved Saved in instrument stat...

Page 298: ...page 298 parameter_table_23 52941 52 94118 Key Path Meas Setup Advanced Setup Mode Sequence Analyzer Initial S W Revision A 11 50 Help Map ID 0 Loopback BER Pattern WCDMA This parameter specifies the...

Page 299: ...PATTern LOAD String SERVice PRODuction LSEQuencer ADVanced WCDMa LBER PATTern LOAD Example SERV LSEQ ADV WCDM LBER PATT LOAD FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF SERV LSEQ AD...

Page 300: ...nce Analyzer Remote Command SERVice PRODuction LSEQuencer ADVanced TDSCdma LBER PATTern filepath filename Example SERV LSEQ ADV TDSC LBER PATT D pat txt State Saved Saved in instrument state Initial S...

Page 301: ...tial S W Revision A 12 00 Help Map ID 0 Loopback BER CodeRMC TD SCDMA This parameter specifies the RMC Reference Measurement Code decoder type used in TD SCDMA Loopback BER calculation Its type is boo...

Page 302: ...BER CINDex0 Example LSEQ ADV TDSC LBER CIND0 0 LSEQ ADV TDSC LBER CIND0 State Saved Saved in instrument state Initial S W Revision A 12 00 Help Map ID 0 Loopback BER Code Index1 TD SCDMA This paramete...

Page 303: ...xample SERV LSEQ ADV TDSC LBER TFCI AUTO TRUE SERV LSEQ ADV TDSC LBER TFCI AUTO State Saved Saved in instrument state Initial S W Revision A 12 00 Help Map ID 0 Loopback BER TFCI Word TD SCDMA This pa...

Page 304: ...mote Command SENSe LSEQuencer ADVanced TDSCdma PVT DEMod ON OFF 1 0 SENSe LSEQuencer ADVanced TDSCdma PVT DEMod Example SENS LSEQ ADV TDSC PVT DEM 1 SENS LSEQ ADV TDSC PVT DEM Preset ON State Saved Sa...

Page 305: ...have bursts is not supported Below are two examples If Trigger Type is Video make sure the sequence won t be triggered by the signal other than the burst being analyzed Generally the signal being tes...

Page 306: ...is on Basic TX Power is configured on each analysis step otherwise Basic IQ Power is configured Append enable optional node used to specify whether the new generated acquisitions of ILPC will be appe...

Page 307: ...version for sequence studio This command is used by Sequence Studio to query the supported sequence file version of both Sequence Analyzer and Source This command is query only parameter_table_23 5294...

Page 308: ...ill be appended at the end of the specified acquisition otherwise the existing analysis steps will be overwritten by the new generated analysis steps parameter_ table_ 23 52941 52 94118 Key Path SCPI...

Page 309: ...ent WLAN radio standards within the same sequence for example selecting both 802 11a and 802 11n a special provision has been made for setting up multiple radio standards for WLAN measurements within...

Page 310: ...W Revision A 14 50 Help Map ID 0 Acquisition configuration set parameter_ table_ 23 52941 52 94118 Parameter Name Acquisition Configuration set Key Path SCPI only Parameter Type StringParameter Remote...

Page 311: ...N SEM settings in 801 11n 40Mhz 11 config other WLAN EVM settings in 801 11n MHz 12 LSEQ CONF ADD WLAN CONFIG_11n40 Add and save all current settings of WLAN now it is in 801 11n 40Mhz 13 config the s...

Page 312: ...ameter please see the online help associated with the measurement The SCPI that is used within the Sequence Analyzer mode is the same as in the GSM EDGE mode except that two additional nodes are requi...

Page 313: ...er ABSolute Upper Mask Absolute Amplitude SENSe EPVTime MASK LIST UPPer POINts Upper Mask Points SENSe EPVTime MASK LIST UPPer RELative rel_ ampl SENSe EPVTime MASK LIST UPPer RELative Upper Mask Rela...

Page 314: ...SENSe RADio STANdard PRESet Preset to Standard SENSe PVTime BANDwidth freq SENSe PVTime BANDwidth BW Maxim um is 40MH z SENSe PVTime RAMP SEARch LENGth time SENSe PVTime RAMP SEARch LENGth Ramp Time...

Page 315: ...sociated with the measurement The SCPI that is used within the Sequence Analyzer mode is the same as in the TDSCDMA mode except that two additional nodes are required in the Sequence Analyzer mode one...

Page 316: ...Solute ampl ampl ampl ampl SENSe PVTime MASK LIST UPPer ABSolute Note 1 Upper Mask Absolute Amplitude Levels SENSe PVTime MASK LIST UPPer POINts Note 1 Upper Mask Points SENSe PVTime MASK LIST UPPer R...

Page 317: ...SENSe TDEMod CDCHannel DETection Note 2 Code Channel Detection SENSe TDEMod MODScheme AUTO 1 0 ON OFF SENSe TDEMod MODScheme AUTO Mod Scheme SENSe TDEMod CDCHannel ACTive spread_code_ length code_chan...

Page 318: ...d one to identify the mode from which the measurement comes For example SENSe PFERror is replaced with SENSe LSEQuencer EDGE PFERror or CALCulate LSEQuencer EDGE PFERror non_parameter_table_29 59967 8...

Page 319: ...864379 10 14706 Command Description Notes SENSe EORFSpectrum TYPE MODulation MSWitching SWITching FFModulation SENSe EORFSpectrum TYPE Meas Type SENSe EORFSpectrum MEASure MULTiple SINGle SWEPt SENSe...

Page 320: ...Limit Level Offset For Custom Modulation SENSe EORFSpectrum LIST MODulation APPLy RELative BOTH ABSolute SENSe EORFSpectrum LIST MODulation APPLy Apply Limit Level Offset List For Custom Modulation S...

Page 321: ...GE EEVM or CALCulate LSEQuencer EDGE EEVM non_parameter_table_32 9902 9 289216 12 64706 9 918301 15 22059 Command Description Notes SENSe EEVM BSYNc SOURce Burst Sync CALCulate EEVM LIMit TEST STATe L...

Page 322: ...ALCulate EEVM LIMit MS NORMal EVMP95 95 ile EVM Test Limit MS Normal CALCulate EEVM LIMit MS EXTReme EVMP95 95 ile EVM Test Limit MS Extreme CALCulate EEVM LIMit BTS NORMal IQOOffset IQ Origin Offset...

Page 323: ...in the List Sequencer measurement are listed below For complete details of each parameter please see the online help associated with the measurement The SCPI that is used within the Sequence Analyzer...

Page 324: ...1 2 CPSD PSD reference SENSe ACPower CARRier 1 2 LIST COUPle Carrier Coupling SENSe ACPower CARRier 1 2 LIST PPResent Carrier Power Present SENSe ACPower CARRier 1 2 LIST WIDTh Carrier spacing Maximu...

Page 325: ...ee the online help associated with the measurement The SCPI that is used within the Sequence Analyzer mode is the same as in the original mode of the measurement except that two additional nodes are r...

Page 326: ...tart Freq Maximum is 20 MHz SENSe SEMask OFFSet 1 2 LIST STATe Offset state list SENSe SEMask OFFSet 1 2 LIST FREQuency STOP Offset Stop Freq Maximum is 20 MHz SENSe SEMask OFFSet 1 2 LIST SIDE Offset...

Page 327: ...thin the Sequence Analyzer mode is the same as in the original mode of the measurement except that two additional nodes are required in the Sequence Analyzer mode one to identify the List Sequencer me...

Page 328: ...please see the online help associated with the measurement The SCPI commands with strikethroughs are in the one button meas but are not allowed to be used within the List Sequencer measurement The SCP...

Page 329: ...is replaced with CALCulate LSEQuencer WLAN EVM The node name of WLAN MIMO Modulation Accuracy is EVMMimo so SENSe EVMMimo is replaced with SENSe LSEQuencer WLAN EVMMimo or CALCulate EVMMimo is replac...

Page 330: ...MS SENSe RHO SYNC SCRamble BTS Primary Scramble Code BTS Only SENSe RHO SFORmat MS Slot Format MS Only SENSe RHO PRACh SIGNature Preamble signature MS Only SENSe RHO SYNC SCRamble BTS OFFSet Scramble...

Page 331: ...Tolerance Range SENSe RHO PICH SPRead PICH Code Number SENSe RHO MICH SPRead MICH Code Number BTS Only parameter_table_23 53758 52 93301 Help Map ID 35226 TDSCDMA RHO non_parameter_table_22 44281 1 81...

Page 332: ...it for MS The default value for MS is 21 0 dB which is defined in 3GPP TS34 122 5 7 2 CALCulate EVM LIMit 1 FERRor Frequency Error Limit for BTS The default value for BTS is 0 05ppm relative to carrie...

Page 333: ...HT Sig is Off When Result Length is Auto the analyzer automatically determines the measurement result length by burst search SENSe EVM TIME RESult LENGth integer Result Length For 802 11a g OFDM and...

Page 334: ...the detected result length to Max Result Length parameter and uses the smaller value as the measurement result length CALCulate EVM SUBCarrier ALL PILOt SINGle Subcarrier This parameter specifies whe...

Page 335: ...hase specifies whether the analyzer tracks phase changes in the pilot subcarriers CALCulate EVM PILot TRACk TIMing OFF ON 0 1 Track Timing specifies whether the analyzer tracks timing changes in the p...

Page 336: ...Sets 6 Mbits s RMS EVM limit CALCulate EVM LIMit RMS M9 rel_ampl 9 Mbits s RMS EVM Sets 9 Mbits s RMS EVM limit CALCulate EVM LIMit RMS M12 rel_ ampl 12 Mbits s RMS EVM Sets 12 Mbits s RMS EVM limit...

Page 337: ...B4 rel_ampl 256QAM 3 4 RMS EVM Sets 256QAM coding rate 3 4 RMS EVM limit CALCulate EVM LIMit RMS QA256 R5B6 rel_ampl 256QAM 5 6 RMS EVM Sets 256QAM coding rate 5 6 RMS EVM limit CALCulate EVM LIMit RM...

Page 338: ...it CALCulate EVMMimo LIMit RMS QA16 R3B4 rel_ampl 16QAM 3 4 RMS EVM Sets 16QAM coding rate 3 4 RMS EVM limit CALCulate EVMMimo LIMit RMS QA64 R2B3 rel_ampl 64QAM 2 3 RMS EVM Sets 64QAM coding rate 2 3...

Page 339: ...r please see the online help associated with the measurement The SCPI that is used within the Sequence Analyzer mode is the same as in the original mode of the measurement except that two additional n...

Page 340: ...riginal mode of the measurement except that two additional nodes are required in the Sequence Analyzer mode one to identify the List Sequencer measurement and one to identify the mode from which the m...

Page 341: ...CDPower ASET THReshold Active Set Threshold SENSe CDPower FILTer RRC STATe RRC Filter control SENSe CDPower FILTer ALPHa Filter alpha SENSe CDPower CRATe Chip Rate SENSe CDPower MCEStimator Multi cha...

Page 342: ...etup Help Map ID 0 Phase Discontinuity Meas Setup The Slot Phase mode of UE Power Control measurement used in the W CDMA modes is available in the sequencer where it is called Phase Discontihuity meas...

Page 343: ...ported All the PRACH Power measeureme settings are supported SENSe PCONtrol SBOundary MS Slot Format AUTO CUSTom SENSe PCONtrol SBOundary LIST MS INIT Symbol Boundary Custom Active Channel List MS Ini...

Page 344: ...mode for radio standard is EDGE Code Domain Power measurement used in the W CDMA mode for radio standard is W CDMA Code Domain Power measurement used in the TD SCDMA mode for radio standard is TD SCD...

Page 345: ...SOURce Burst Sync NOTE The parameters of Loopback BER measurement for GSM are the same as the parameters of GMSK Phase Frequency PFER measurement parameter_table_23 53758 52 93301 Help Map ID 35330 ED...

Page 346: ...e CDPower SBOundary LIST MS NCHannels Num channels CALCulate CDPower THSDpcch Time offset tHS DPCCH CALCulate CDPower DTXBurst DTX Burst Detect CALCulate CDPower IQPHase ROTation TX Diversity IQ Axis...

Page 347: ...ower ANALysis SUBFrame Analysis Subframe Specifies which sub frame within the acquired result length is used for analysis and trace data measurement results The available selections should include the...

Page 348: ...t setting for GSM mode Provides an On Off for each timeslot 0 to 7 Generally used only with periodic and ext frame triggers SCPI access only from within Sequence Analyzer mode front panel access throu...

Page 349: ...yzer mode front panel access through the GSM EDGE mode For more information see the online help for GSM EDGE mode The SCPI commands in Sequence Analyzer mode are SENSe LSEQuencer EDGE CHANnel TSCode i...

Page 350: ...EQuencer EDGE SYNC BURSt STHReshold parameter_table_23 53758 52 93301 Help Map ID 0 GSM HSR Pulse Shape Filter HSR Pulse Shaping Filter setting for GSM mode Selects the pulse shaping filter for higher...

Page 351: ...m within Sequence Analyzer mode front panel access through the GSM EDGE mode For more information see the online help for GSM EDGE mode The SCPI commands in Sequence Analyzer mode are SENSe LSEQuencer...

Page 352: ...table_23 53758 52 93301 Help Map ID 0 1xEV DO Physical Layer SubType Physical Layer Subtype setting for1xEV DO mode Allows you to select the subtype used in measurement SCPI access only from within Se...

Page 353: ...SCdma SLOT parameter_table_23 53758 52 93301 Help Map ID 0 TDSCDMA HSPA 8PSK Enable HSPA 8PSK Enable setting for TDSCDMA mode This key is active if the TD SCDMA HSPA 8PSK option license is installed I...

Page 354: ...Uplink Pilot or Downlink Pilot burst and then uses the location of that burst to position all of the rest of the time slots Synchronization will fail if neither pilot burst is found or if the incorre...

Page 355: ...the number of Maximum Users that will be associated with the timeslots 0 The range is 2 16 SCPI access only from within Sequence Analyzer mode front panel access through the TDSCDMA mode For more inf...

Page 356: ...ifies the number of Maximum Users that will be associated with the timeslots 3 The range is 2 16 SCPI access only from within Sequence Analyzer mode front panel access through the TDSCDMA mode For mor...

Page 357: ...mode It specifies the number of Maximum Users that will be associated with the timeslots 6 The range is 2 16 SCPI access only from within Sequence Analyzer mode front panel access through the TDSCDMA...

Page 358: ...cheme setting for TDSCDMA mode This key is only available when HSPA 8PSK Option is installed and the Enable HSPA 8PSK key is set to ON Otherwise its value will be set to AUTO More Information about Mo...

Page 359: ...360 Code Channel Status on page 360 Midamble Shift on page 361 Modulation Format on page 361 Phase Shift on page 361 Phase Shift Detection on page 362 Select Code Length Select Code Length in Channel...

Page 360: ...alue for the code Channel should be Select Code length 1 The Dispread Channel Code Channel is used along with the Dispread Channel Spread Code Length to specify the active code channel and layer used...

Page 361: ...3301 Help Map ID 0 Modulation Format Modulation Format in Channel Configuration setting for TDSCDMA mode If Auto is assigned to a code channel with some spread code length the modulation format on thi...

Page 362: ...ameter_table_23 53758 52 93301 Help Map ID 0 TDSCDMA Demod Timing Reference Timing Reference setting for TDSCDMA mode The available selections include DwPTS UpPTS and Trigger SCPI access only from wit...

Page 363: ...e Channel Threshold Active Channel Threshold setting for TDSCDMA mode Active Channel Threshold lets you set the threshold above which a code channel is detected active and included in the Composite Re...

Page 364: ...ccess through the TDSCDMA mode For more information see the online help for TDSCDMA mode The SCPI commands in Sequence Analyzer mode are SENSe LSEQuencer TDSCdma TDEMod SPECtrum MIRRor NORMal INVert S...

Page 365: ...de are SENSe LSEQuencer WLAN RADio STANdard AG BG GDO N20 N40 AC20 AC40 AC80 ACT80 AC160 SENSe LSEQuencer WLAN RADio STANdard parameter_table_23 53758 52 93301 Help Map ID 0 WLAN Modulation Modulation...

Page 366: ...QAM16 QAM64 QAM256 SIG SENSe LSEQuencer WLAN DEMod AC20 FORMat For Radio Standard 802 11ac 40MHz SENSe LSEQuencer WLAN DEMod AC40 FORMat AUTO BPSK QPSK QAM16 QAM64 QAM256 SIG SENSe LSEQuencer WLAN DEM...

Page 367: ...r SPACing freq SENSe LSEQuencer WLAN DEMod N40 SUBCarrier SPACing For Radio Standard 802 11ac 20MHz SENSe LSEQuencer WLAN DEMod AC20 SUBCarrier SPACing freq SENSe LSEQuencer WLAN DEMod AC20 SUBCarrier...

Page 368: ...adio Standard 802 11n 40MHz SENSe LSEQuencer WLAN DEMod N40 GINTerval R1B4 R1B8 SIG OTHer SENSe LSEQuencer WLAN DEMod N40 GINTerval For Radio Standard 802 11ac 20MHz SENSe LSEQuencer WLAN DEMod AC20 G...

Page 369: ...o Standard 802 11n 20MHz SENSe LSEQuencer WLAN DEMod N20 GINTerval LENGth real SENSe LSEQuencer WLAN DEMod N20 GINTerval LENGth For Radio Standard 802 11n 40MHz SENSe LSEQuencer WLAN DEMod N40 GINTerv...

Page 370: ...e used to upload sequences from the test set for modification and read back and display results The number of analysis steps that are supported in a Sequence is 1000 There is a limit to 512 acquisitio...

Page 371: ...4 7 09150 3 8 91339 9 6 38071 9 9 06862 7 7 32026 1 9 47712 4 6 76470 7 8 67 647 7 687 908 Acq Number Radio Standard Radio Band Device Freq MHz Chan Number of Averages Peak Power dBm Inst Gain dB Tran...

Page 372: ...equence Measurements 1 0 02 0 7 111 5 The full width of the spreadsheet is illustrated below For a description of each column look up the relevant parameter in Meas Setup on page 380 372 Sequence Anal...

Page 373: ...s on limits For a description of each column see the equivalent parameter in Meas Setup Parameters The start of the analyzer sequence in the TSV file is indicated by the row Analyzer Example Acq Numbe...

Page 374: ...non_ paramete r_table_ 8 864379 9 5588 24 7 352941 6 6176 47 7 2385 62 9 2810 46 8 3741 84 6 5277 78 6 8137 25 9 5588 24 Step Number Step Trigger Transition Time ms Radio Band Radio Band Link Freq MHz...

Page 375: ...rop down lists These provide valid selections for the following fields in the tsv table Analyzer Table Radio Standard Trigger Input Trigger Output Filter Type Radio Band Radio Device Inst Gain Source...

Page 376: ...94118 Key Path SCPI only Remote Command SENSe LSEQuencer ACQuire 1 2 4 512 SETup NONE GSM EDGE WCDMA CDMA2K CDMA1XEV LTE LTETDD TDSCDMA NONE PGSM EGSM RGSM DCS1800 PCS1900 TGSM810 GSM450 GSM480 GSM85...

Page 377: ...enum specifies the Input Trigger Type for the Acquisition ampl specifies the Input Trigger Level for the Acquisition time specifies the Input Trigger Delay for the Acquisition enum specifies the Acqu...

Page 378: ...into the test set using a TSV file an initial verification phase is carried out If the file is found to be invalid an error 232 Invalid format syntax error on line 0 is generated For all other setup m...

Page 379: ...nteed for power levels greater than 65 dBm for RFIO paths and 70 dBm for RF In path 2 Expected Power is in conflict with Instrument Gain setting 3 Transition Time is not long enough for the Acquisitio...

Page 380: ...ppropriate mode and make the setup changes the changes are then retained when you switch back to Sequence Analyzer mode parameter_table_23 52941 52 94118 Key Path Meas Mode Sequence Analyzer Initial S...

Page 381: ...ision A 05 00 Help Map ID 35025 Display Results ON OFF The setting of this parameter determines whether or not the results are displayed on the test set s screen parameter_table_23 52941 52 94118 Key...

Page 382: ...R BAND1 BAND2 BAND3 BAND4 BAND5 BAND6 BAND7 BAND8 BAND9 BAND10 BAND11 BAND12 BAND13 BAND14 BAND17 BAND18 BAND19 BAND20 BAND21 BAND24 BAND25 BAND26 BAND27 BAND28 BAND30 BAND31 BAND33 BAND34 BAND35 BAND...

Page 383: ...apter Input path selection enum specify the step Multiport Adapter Preamplify On Off enum specify the Integration type of current acquisition this is for Span extension and Range extension enum specif...

Page 384: ...set 1 Range 1 to Number of Acquisitions Min 1 Max Number of Acquisitions Initial S W Revision A 05 00 Help Map ID 35028 Insert Before Acquisition This inserts a default Acquisition before the current...

Page 385: ...cer ACQuire 1 512 SETup AVERage NUMBer To set the average number as an array SENSe LSEQuencer LIST SETup AVERage NUMBer integer integer integer SENSe LSEQuencer LIST SETup AVERage NUMBer The array for...

Page 386: ...peating elements of the signal within an acquisition must have the same duration The Transition time only applies to the last acquisition capture in the average group 11 The repeating elements of the...

Page 387: ...page 393 Mod Scheme Last Value Averaging on page 393 Estimated Carrier Power Logarithmic Averaging on page 393 ORFS Front Panel Power Control Level Not averaged but uses averaged Ref Power result to...

Page 388: ...MS Phase Error Linear Averaging on page 393 Avg Peak Phase Error Linear Averaging on page 393 Max Peak Phase Error Max Hold Averaging on page 394 Peak Phase Error Position Last Value Averaging on page...

Page 389: ...l Power Logarithmic Averaging on page 393 Upper Abs Power Logarithmic Averaging on page 393 SEM Total Power Ref Logarithmic Averaging on page 393 Peak Freq Ref Max Hold Averaging on page 394 Repeat fo...

Page 390: ...DMA only Peak Active Code Domain Error Max Hold Averaging on page 394 TDSCDMA only Peak Active Code Domain Error Code Length Not averaged but uses averaged Peak Actvie Code Domain Error to compute thi...

Page 391: ...ar Averaging on page 393 Half Slot Peak Code Domain Error Max Hold Averaging on page 394 Half Slot Peak Code Domain Error Channel Number Not averaged but uses averaged Half Slot Peak Code Domain Error...

Page 392: ...ge 393 RP1Normal Linear Averaging on page 393 RP2Normal Linear Averaging on page 393 RP12Normal Linear Averaging on page 393 RP21Normal Linear Averaging on page 393 EcMax1Extreme Linear Averaging on p...

Page 393: ...e Error Can t work with averaging NAN will be returned if Average Count is set to greated than 1 Repeat for each slot RMS Phase Error Can t work with averaging NAN will be returned if Average Count is...

Page 394: ...ccess to the Radio Setup sub menus parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Notes No SCPI Front panel only Initial S W Revision A 05 00 Help Map ID 35032 Radio Standard...

Page 395: ...TDD TDSCDMA WLAN SENSe LSEQuencer ACQuire 1 512 SETup RADio STANdard To set Radio Standard as an array SENSe LSEQuencer LIST SETup RADio STANdard enum enum enum SENSe LSEQuencer LIST SETup RADio STANd...

Page 396: ...sequence the number of array values must match the number of acquisitions otherwise a settings conflict error will occur Example LSEQ ACQ2 SET RAD BAND NONE LSEQ ACQ2 SET RAD BAND LSEQ LIST SET RAD B...

Page 397: ...rogramming Acquisitions Via SCPI on page 376 State Saved Saved in instrument state Range NONE PGSM EGSM RGSM DCS1800 PCS1900 TGSM810 GSM450 GSM480 GSM700 GSM850 Initial S W Revision A 05 00 Help Map I...

Page 398: ...Initial S W Revision A 05 00 Help Map ID 35038 DCS 1800 Selects DCS1800 for the Band for GSM parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard GSM Ini...

Page 399: ...parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard GSM Initial S W Revision A 05 00 Help Map ID 35045 GSM 700 Selects GSM 700 for the Band for GSM param...

Page 400: ...in the sequence the number of array values must match the number of acquisitions otherwise a settings conflict error will occur Example LSEQ ACQ2 SET RAD BAND NONE LSEQ ACQ2 SET RAD BAND LSEQ LIST SE...

Page 401: ...Radio Standard EDGE Initial S W Revision A 05 00 Help Map ID 35048 RGSM Selects RGSM for the Band for EDGE parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Sta...

Page 402: ...the Band for EDGE parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard EDGE Initial S W Revision A 05 00 Help Map ID 35054 GSM 850 Selects GSM 850 for th...

Page 403: ...I BandXIII BandXIV bandxix SENSe LSEQuencer ACQuire 1 512 SETup RADio BAND To set Radio Band as an array SENSe LSEQuencer LIST SETup RADio BAND enum enum enum SENSe LSEQuencer LIST SETup RADio BAND Th...

Page 404: ...lects Band I for the Band for WCDMA HSPA parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard WCDMA HSPA Initial S W Revision A 05 00 Help Map ID 35058 Ba...

Page 405: ...94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard WCDMA HSPA Initial S W Revision A 05 00 Help Map ID 35062 Band VI Selects Band VI for the Band for WCDMA HSPA parameter_table_23...

Page 406: ...HSPA Initial S W Revision A 05 00 Help Map ID 35066 Band X Selects Band X for the Band for WCDMA HSPA parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standar...

Page 407: ...elects Band XIV for the Band for WCDMA HSPA parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard WCDMA HSPA Initial S W Revision A 05 00 Help Map ID 35071...

Page 408: ...SEQ ACQ2 SET RAD BAND LSEQ LIST SET RAD BAND BAND1 NONE BAND24 BAND21 LSEQ LIST SET RAD BAND Not es For setting this parameter using SCPI see Programming Acquisitions Via SCPI on page 376 Stat e Sav e...

Page 409: ...p Radio Standard LTE FDD Initial S W Revision A 09 50 Help Map ID 35294 BAND3 Selects BAND3 for the Band for LTE FDD parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup...

Page 410: ...Band for LTE FDD parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard LTE FDD Initial S W Revision A 09 50 Help Map ID 35299 BAND8 Selects BAND8 for the B...

Page 411: ...Radio Standard LTE FDD Initial S W Revision A 09 50 Help Map ID 35303 BAND12 Selects BAND12 for the Band for LTE FDD parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setu...

Page 412: ...Band for LTE FDD parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard LTE FDD Initial S W Revision A 09 50 Help Map ID 35308 BAND19 Selects BAND19 for the...

Page 413: ...Radio Standard LTE FDD Initial S W Revision A 09 50 Help Map ID 35325 BAND25 Selects BAND25 for the Band for LTE FDD parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setu...

Page 414: ...tup Radio Setup Radio Standard LTE FDD Initial S W Revision A 14 00 Help Map ID 37059 LTE TDD Selects LTE TDD for the Radio Standard for the current Acquisition and allows selection of the LTE TDD ban...

Page 415: ...ND42 BAND43 BAND 44 Initial S W Revision A 12 00 Help Map ID 37001 None Selecting None for LTE TDD means that in the Acquisition the frequency of the LTE TDD signal is determined by the Frequency para...

Page 416: ...y Path Meas Setup Acquisition Setup Radio Setup Radio Standard LTE TDD Initial S W Revision A 12 00 Help Map ID 37006 BAND 37 Selects BAND 37 for the Band for LTE TDD parameter_table_23 52941 52 94118...

Page 417: ...E TDD Initial S W Revision A 12 00 Help Map ID 37010 BAND 41 Selects BAND 41 for the Band for LTE TDD parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard...

Page 418: ...Command To set Radio Band individually SENSe LSEQuencer ACQuire 1 512 SETup RADio BAND NONE BANDA BANDB BANDC BANDD BANDE BANDF SENSe LSEQuencer ACQuire 1 512 SETup RADio BAND To set Radio Band as an...

Page 419: ...Setup Radio Standard TDSCDMA Initial S W Revision A 12 00 Help Map ID 37015 BAND A Selects BAND A for the Band for TDSCDMA parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radi...

Page 420: ...nd for TDSCDMA parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Radio Setup Radio Standard TDSCDMA Initial S W Revision A 12 00 Help Map ID 37021 Device For Channel This paramet...

Page 421: ...T SET RAD DEV MS MS MS LSEQ LIST SET RAD DEV Notes For setting this parameter using SCPI see Programming Acquisitions Via SCPI on page 376 This parameter and the Band parameter are used to determine w...

Page 422: ...nel number Example LSEQ ACQ2 SET CNFR 150 LSEQ ACQ2 SET CNFR LSEQ LIST SET CNFR 1102 1e9 1 3e9 2300 LSEQ LIST SET CNFR Notes For setting this parameter using SCPI see Programming Acquisitions Via SCPI...

Page 423: ...f acquisitions otherwise a settings conflict error will occur NOTE when the radio band is NONE these SCPI commands are to configure Frequency otherwise these commands are to configure channel number E...

Page 424: ...used to make a different setting for each acquisition in the sequence the number of array values must match the number of acquisitions otherwise a settings conflict error will occur Example LSEQ ACQ2...

Page 425: ...ns otherwise a settings conflict error will occur Example LSEQ ACQ2 SET TIME TRAN 10ms LSEQ ACQ2 SET TIME TRAN LSEQ LIST SET TIME TRAN 500us 1ms 2ms LSEQ LIST SET TIME TRAN Notes For setting this para...

Page 426: ...Acquisition Setup Remote Command To set Duration Time individually SENSe LSEQuencer ACQuire 1 512 SETup TIME DURation time SENSe LSEQuencer ACQuire 1 512 SETup TIME DURation To set the Duration Time a...

Page 427: ...LSEQuencer LIST SETup TRIGger INPut The array form of the command is used to make a different setting for each acquisition in the sequence the number of array values must match the number of acquisit...

Page 428: ...tion parameter_table_23 52941 52 94118 Key Path Meas Setup Acquisition Setup Input Trigger Initial S W Revision A 05 00 Help Map ID 35116 External 1 Selects External 1 for the Trigger for the current...

Page 429: ...SENSe LSEQuencer ACQuire 1 512 SETup TRIGger INPut LEVel To set the Intput Trigger Level as an array SENSe LSEQuencer LIST SETup TRIGger INPut LEVel amp amp amp SENSe LSEQuencer LIST SETup TRIGger INP...

Page 430: ...error will occur Example LSEQ ACQ2 SET TRIG INP DEL 200us LSEQ ACQ2 SET TRIG INP DEL LSEQ LIST SET TRIG INP DEL 0 200us 100us LSEQ LIST SET TRIG INP DEL Notes For setting this parameter using SCPI se...

Page 431: ...eas Setup Acquisition Setup Remote Command To set Ouput Trigger Type individually SENSe LSEQuencer ACQuire 1 512 SETup TRIGger OUTPut NONE INTernal SENSe LSEQuencer ACQuire 1 512 SETup TRIGger OUTPut...

Page 432: ...Path Meas Setup Acquisition Setup Acquisition Output Trigger Initial S W Revision A 05 00 Help Map ID 35123 Integration Type This parameter extends the Span and Range capability of the Sequence Analy...

Page 433: ...h Meas Setup Acquisition Setup Acquisition Integration Initial S W Revision A 11 00 Help Map ID 35335 Upper Set the acquisition integration type to upper and it will be integrated with with the last P...

Page 434: ...isition step parameter_ table_ 23 52941 52 94118 Key Path Meas Setup Acquisition Setup Notes For setting this parameter using SCPI see Programming Acquisitions Via SCPI on page 376 For the E6640A with...

Page 435: ...RF Input parameter_ table_ 23 52941 52 94118 Key Path Meas Setup Acquisition Setup Acquisition RF Input Port Notes For the E6640A with standard TRX hardware M9430A or the E6650A with the standard TRX...

Page 436: ...lysis Steps This parameter is used to define the number of Analysis periods within the current Acquisition parameter_ table_ 23 52941 52 94118 Key Path Meas Setup Acquisition Setup Analysis Setup Remo...

Page 437: ...up Analysis Step Setup Notes For setting this parameter using SCPI see Programming Acquisitions Via SCPI on page 376 Couplings Updates UI Analysis parameters to selected Analysis Step Preset 1 Range 1...

Page 438: ...ually SENSe LSEQuencer ACQuire 1 512 ASTep 1 1000 SETup TIME OFFSet time SENSe LSEQuencer ACQuire 1 512 ASTep 1 1000 SETup TIME OFFSet To set the Analysis Offset as an array SENSe LSEQuencer ACQuire 1...

Page 439: ...ing Acquisitions Via SCPI on page 376 Preset 0 s State Saved Saved in instrument state Range 0 s to 1 s Min 0 s Max 1 s Initial S W Revision A 05 00 Help Map ID 35133 Analysis Interval This parameter...

Page 440: ...ision A 05 00 Help Map ID 35134 Measurement Bitmap Allows you to select which measurements are included in an analysis step Measurement bitmap choice differs for each radio standard See the table belo...

Page 441: ...have one of them But now the two options are combined Strictly speaking GMSK Phase Freq is GSM measurement EDGE EVM is EDGE measurement Here we let GSM and EDGE share these measurements for convenien...

Page 442: ...meter is the decimal number 129 Dependencies When this parameter is set up using Programming Acquisitions Via SCPI on page 376 the value must be entered as the decimal equivalent of the bits For examp...

Page 443: ...he Basic Discrete PAvT Phase Amplitude versus Time measurement is computed on the selected analysis step parameter_table_23 52941 52 94118 Key Path Meas Setup Step Setup Meas Bit Mask Preset Off State...

Page 444: ...analysis step parameter_table_23 52941 52 94118 Key Path Meas Setup Step Setup Meas Bit Mask Dependencies This parameter is only enabled when the Radio Standard parameter is set to GSM or EDGE Preset...

Page 445: ...d analysis step parameter_table_ 23 52941 52 94118 Key Path Meas Setup Step Setup Meas Bit Mask Dependencies This parameter is only enabled when the Radio Standard parameter is set to WCDMA cdma2000 1...

Page 446: ...instrument state Range On Off Initial S W Revision A 05 00 Help Map ID 35145 Modulation Accuracy This parameter determines if the Modulation Accuracy measurement is computed on the selected analysis...

Page 447: ...tup Step Setup Meas Bit Mask Dependencies This parameter is only enabled when the Radio Standard parameter is set to WCDMA or TDSCDMA Preset Off State Saved Saved in instrument state Range On Off Init...

Page 448: ...ted for one analysis of this acquisition parameter_table_23 52941 52 94118 Key Path Meas Setup Basic Meas Setup Mode Sequence Analyzer Initial S W Revision A 05 00 Help Map ID 35279 Interval Count Thi...

Page 449: ...in instrument state Range 50us to 399 95ms Min 50 us Max 399 95 ms Initial S W Revision A 05 00 Help Map ID 0 Interval Widths This parameter sets the interval width of each step to be measured parame...

Page 450: ...Step Setup Remote Command To set Expected Power individually SENSe LSEQuencer ACQuire 1 512 ASTep 1 1000 SETup EPOWer amp SENSe LSEQuencer ACQuire 1 512 ASTep 1 1000 SETup EPOWer To set Expected Powe...

Page 451: ...Setup Provides access to setup menus for the four basic measurements included in Sequence Analyzer mode Basic Transmit Power Basic Frequency and Phase Error Basic Discrete PAvT and Basic IQ Data para...

Page 452: ...D and TDD 1 Bandwidth 1 6 Bandwidth Short Nyquist Alpha 0 1 TDSCDMA 1 5e6 1 5e6 RRC Alpha 0 22 Note 1 The bandwidth of LTE could be changeable The current bandwidth can be derived from Mode Setup Demo...

Page 453: ...s Fail result is 1 If above the Pass Fail result is 0 When set to OFF the measurement populates the Pass Fail result with 1 signifying it s untested This parameter is also coupled with amplitude corre...

Page 454: ...of the digital receiver parameter_table_ 23 52941 52 94118 Key Path Meas Setup Basic Meas Setup Basic Transmit Power Setup Radio Std None Remote Command SENSe LSEQuencer BTXPower NONE DIF BANDwidth B...

Page 455: ...Radio Standard of the acquisition is set to None parameter_table_23 52941 52 94118 Key Path Meas Setup Basic Meas Setup Basic Transmit Power Setup Radio Std None Filter Type Initial S W Revision A 05...

Page 456: ...BTXPower NONE DIF FILTer BANDwidth BWIDth RESolution freq SENSe LSEQuencer BTXPower NONE DIF FILTer BANDwidth BWIDth RESolution Example LSEQ BTXP DIF FILT BAND 1 kHz LSEQ BTXP DIF FILT BAND Dependenci...

Page 457: ...ples the result returned is the average The result returned are Frequency Error and Phase Error with reference to the frequency set for the acquisition Undetermined phase changes occur between acquisi...

Page 458: ...pass fail limit for the frequency error result Units are in parts per million ppm parameter_table_ 23 52941 52 94118 Key Path Meas Setup Basic Meas Setup Remote Command SENSe LSEQuencer BFERor LIMit...

Page 459: ...es the Filter Type function which enables you to manually set the channel filter bandwidth of the analyzer by selecting different filter type This is used to set the channel filter of the EXT Analyzer...

Page 460: ...asic Discrete PAvT Setup Filter Type Initial S W Revision A 05 00 Help Map ID 35283 Extremely Narrow Selects Extremely Narrow for the filter type and its actual filter is short nyquist filter of filte...

Page 461: ...analyzer This is used to set the digital IF filter of the EXT Analyzer parameter_ table_ 23 52941 52 94118 Key Path Meas Setup Basic Meas Setup Basic IQ Data Setup Remote Command SENSe LSEQuencer BIQD...

Page 462: ...n the Sequence parameters which are being used by the test set parameter_table_23 52941 52 94118 Key Path Meas Setup Initial S W Revision A 05 00 Help Map ID 35196 Min Signal To Noise Ratio Margin Thi...

Page 463: ...r setting 5 dB Increasing the margin may cause the test set to increase its attenuation If the Auto Set RF Level is set to OFF then these additional parameters are disabled parameter_table_23 52941 52...

Page 464: ...then no trigger timeout error is thrown and this parameter is disabled parameter_table_23 52941 52 94118 Key Path Meas Setup Remote Command SENSe LSEQuencer TIMeout TRIGger time SENSe LSEQuencer TIMe...

Page 465: ...nce if any more acquisitions or measurements have still to be made When set to OFF if any measurements fail their limits then the sequence acquisitions and measurements carry on regardless This only a...

Page 466: ...ort On Error Mode SEQA Remote Command SENSe LSEQuencer ABORt ERRor STATe ON OFF 1 0 SENSe LSEQuencer ABORt ERRor STATe Example LSEQ ABOR ERR ON LSEQ ABOR ERR Preset OFF State Saved Saved in instrument...

Page 467: ...n 0 s Max 4 s Initial S W Revision A 11 50 Help Map ID 35339 Holdoff Type Lets you set the Trigger Holdoff Type Above or Below Above If the trigger slope is positive a trigger event is generated only...

Page 468: ...lp Map ID 35340 Video Sets the trigger type to Video that is IF envelope triggering parameter_table_23 52941 52 94118 Key Path Meas Setup Input Trigger Setup Mode Sequence Analyzer Initial S W Revisio...

Page 469: ...ernal1 LEVel Example TRIG LSEQ EXT1 LEV 1 0 TRIG LSEQ EXT1 LEV Dependencies This parameter is used for Ext1 trigger only Disabled if anything else Preset 1 2 V State Saved Saved in instrument state Mi...

Page 470: ...Revision A 05 00 Help Map ID 35207 Trigger Level Sets the voltage level for the External 2 trigger parameter_table_23 52941 52 94118 Key Path Meas Setup Input Trigger Setup Remote Command TRIGger LSEQ...

Page 471: ...e test set s analyzer a switched IF amplifier with approximately 10 dB of gain can be toggled If it can be turned on without an overload the dynamic range is always better with it on than off The IF G...

Page 472: ...tion parameter_table_23 53758 52 93301 Key Path Meas Setup Help Map ID 35216 RF Input Port Mode When this parameter is set to List RF Input path of each acquisition can be set independently see Sectio...

Page 473: ...6 List Sequence Measurements Meas Setup State Saved Saved in instrument state Range Fxied List Initial S W Revision A 14 00 Help Map ID 37052 Sequence Analyzer User s Programmer s Reference 473...

Page 474: ...6 List Sequence Measurements Mode Mode See Mode on page 130 474 Sequence Analyzer User s Programmer s Reference...

Page 475: ...ent and gets the mode to a consistent state with all of the default couplings set Backwards Compatibility Notes In the X Series the legacy Factory Preset has been replaced with Mode Preset which only...

Page 476: ...es except the persistent ones Restore Mode Defaults resets ALL the Mode variables and all the Meas global and Meas local variables including the persistent ones Type Of Preset SCPI Command Front Panel...

Page 477: ...s Mode Preset Power On Mode Preset SYSTem PON TYPE MODE System Menu Power On User Preset SYSTem PON TYPE USER System Menu Power On Last State SYSTem PON TYPE LAST System Menu Sequence Analyzer User s...

Page 478: ...6 List Sequence Measurements Print Print See Print on page 151 478 Sequence Analyzer User s Programmer s Reference...

Page 479: ...Trace State State_ Save Recall Screen Screen_ Save Recall Amplitude Corrections Ampcor_ Import Export Traces Trace_ Import Export Limit Lines LLine_ Import Export Measurement Result MeasR_ Import Expo...

Page 480: ...fred_0000 csv Although 0000 is used in the example above the number that is used is actually the current number in the Meas Results sequence that is the number that would have been used if you had no...

Page 481: ...st for settings that may vary with version number model number option and license differences If you try to recall a state file onto an instrument with less capability than what was available on the i...

Page 482: ...s loads the state file data on the default file directory path into the instrument state Notes When you pick a file to recall the analyzer first verifies that the file is recallable in the current ins...

Page 483: ...lank mode before saving The following table describes the Trace Save and Recall possibilities You want to recall state and one trace s data leaving other traces unaffected Save Trace State from 1 trac...

Page 484: ...uch as Look In Look In The Look In field shows the path from which the file will be recalled and allows you to change the path using the up and down arrow keys to navigate to other paths the Enter key...

Page 485: ...ses the current Open request to be cancelled The ESC key does the same thing Key Path Recall State Notes Brings up the Open dialog for recalling a State Save Type Initial S W Revision Prior to A 02 00...

Page 486: ...it Register Names key OR empty if no prior save operation has been performed to this register Initial S W Revision Prior to A 02 00 Modified at S W Revision Prior to A 11 00 Register 1 thru Register 1...

Page 487: ...e loaded into the Stated Sequencer Once selected in order to import the selected Sequence Type you must select the Open key in the Source Sequence menu Key Path Recall Sequences Mode All Remote Comman...

Page 488: ...ompletely configurable and can have internal triggers between the source and the analyzer to orchestrate a sequence to completely test an external transmitter and receiver s performance Key Path Recal...

Page 489: ...available for the mode Some keys will be missing completely so the key locations in the sub menu will vary No SCPI command directly controls the Data Type that this key controls The Data Type is inclu...

Page 490: ...er option installed in your instrument This command will generate an Option not available error unless you have the proper option installed in your instrument Couplings When a correction file is loade...

Page 491: ...thout using a keyboard or mouse The Tab and Arrow keys can also be used for dialog navigation See From File on page 483in Recall State for a full description of this dialog and menu Key Path Recall Da...

Page 492: ...he SWEEPING bit is set The MEASURING bit is set Backwards Compatibility Notes For Spectrum Analysis mode in ESA and PSA the Restart hardkey and the INITiate RESTart command restart trace averages disp...

Page 493: ...dition is met and the analyzer stops sweeping once that sweep has completed However with Average Hold Number 1 and at least one trace set to Trace Average Max Hold or Min Hold SA Measurement or Averag...

Page 494: ...included even though they are outside of the Mode s state because they are needed to restore the complete setup Persistent System settings for example Verbose SCPI are not affected by either Mode Pres...

Page 495: ...indows dialog without using a keyboard or mouse The Tab and Arrow keys can also be used for dialog navigation The Listed below are the functions of the various fields in the dialog and the correspondi...

Page 496: ...Use the knob to choose the letter to add and the front panel Enter key to add the letter to the file name The BK character moves you back and the FW character moves you forward in the filename The Se...

Page 497: ...ceeds 30 characters an error message is generated 150 String data error Label clipped to 30 characters label of length 0 erases the custom label and restores the default time and date label E g MMEM R...

Page 498: ...om is saved with it then when it is recalled the instrument switches to that Mode After the save completes the corresponding register menu key annotation is updated with the date and time and the mess...

Page 499: ...The string must be a valid logical path Queries disk usage information drive capacity free space available and obtains a list of files and directories in a specified directory in the following format...

Page 500: ...cify the source The second and fourth parameters specify the directories The first pair of parameters specifies the source The second pair specifies the destination An error is generated if the source...

Page 501: ...k format Initial S W Revision Prior to A 02 00 Mass Storage Make Directory Remote Command Only Key path SCPI Only Remote Command MMEMory MDIRectory directory_name Notes The string must be a valid logi...

Page 502: ...moved All files and directories under the specified directory shall also be removed This command will generate an access denied error if the folder is a restricted folder e g C Windows or is in a rest...

Page 503: ...nalyzer Sequence Available in Sequence Analyzer Mode The list of parameters that configure steps that makes up a sequence for the Analyzer and the Source The Source and Analyzer sequence is completely...

Page 504: ...you to specify the destination file and directory Once a filename has been selected or entered in the Open menu the export will occur as soon as the Save key is pressed Key Path Save Mode All Notes Th...

Page 505: ...compatibility ANTenna maps to 1 CABle maps to 2 OTHer maps to 3 and USER maps to 4 Initial S W Revision A 02 00 Correction Data File A Corrections Data File contains a copy of one of the analyzer corr...

Page 506: ...oth are read only they are never written by the analyzer The only way to insert or modify these rows is to edit the file with a text editor or a spreadsheet editor These rows are intended for use by m...

Page 507: ...the correction data is 0 dB at 200 MHz 17 dB at 210 MHz 14 8 dB at 225 MHz Then the file will look like Amplitude Correction Correction Factors for 11966E Class B Radiated A 02 06 N9020A P13 EA3 UK6...

Page 508: ...rement Results Data Files My Documents mode name data measurement name results For all of the Capture Buffer Data Files My Documents mode name data captureBuffer Key Path Save Data Mode All Notes The...

Page 509: ...until the measurement is complete After you have completed the save the Quick Save front panel key lets you quickly repeat the last save performed using an auto named file with the current screen data...

Page 510: ...rse Bitmap or Reverse Metafile when saving screen images This is much like the Flat Color theme available in X Series Also if you selected Reverse Bitmap AND a black white screen image that would be m...

Page 511: ...og and a menu entitled Save As This menu allows you to navigate to the various fields in the Windows dialog without using a keyboard or mouse The Tab and Arrow keys can also be used for dialog navigat...

Page 512: ...in the idle state INIT IMM in ESA PSA Spectrum Analysis Mode does an implied ABORt In some other PSA Modes INIT IMM is ignored if not in the idle state The X Series follows the ESA PSA SA Mode model w...

Page 513: ...on front panel to indicate out of scope Non forceful means user still can change this setting by SCPI but cannot change on front panel When set to OFF will make source leave list sequencer and this se...

Page 514: ...p s output power The multiport adapter RFIO TX ports and GPS ports cannot ensure power accuracy when power setting is lower than 130dBm this power setting value is defined by the sum of RF Power setti...

Page 515: ...e reference power by the value entered under Source Amplitude RF Power as follows Output power reference power entered power Where reference power equals the original RF Power entered under Source Amp...

Page 516: ...s value is coupled to the Set Reference Power on page 515 key such that pressing the Set Reference Power key updates the reference power with the current output power Preset 0 00 dBm OFF Min 125 00 dB...

Page 517: ...ng is for independent mode and has no effect on List Sequencer on page 596 If the Sequencer on page 597 is set to ON the list sequencer controls the source output and this key will be grayed out And t...

Page 518: ...which contain separate output power frequency and waveform etc When the source list sequence playing is complete the last step keeps playing and user can use this command to change the list sequence...

Page 519: ...e channel number Preset 1 Min Please refer to the tables below for the valid ranges Max Please refer to the tables below for the valid ranges Initial S W Revision A 05 00 GSM EDGE Channel Number Range...

Page 520: ...0 n 425 n 5 1850 1 n 5 Band III Downlink 1162 n 1513 n 5 1575 Uplink 937 n 1288 n 5 1525 Band IV Downlink 537 n 1738 1887 n 2087 n 5 1805 n 5 1735 1 Uplink 1312 n 1513 1662 n 1862 n 5 1450 n 5 1380 1...

Page 521: ...plink 3892 n 3918 3942 n 3967 n 5 12 n 5 2 1 Band XIX Downlink 712 n 763 787 n 837 n 5 735 n 5 720 1 Uplink 312 n 363 387 n 437 n 5 770 n 5 755 1 CDMA 2000 1xEVDO Channel Number Ranges Band Link Devic...

Page 522: ...71 1039 N 1473 1536 N 1715 1792 N 2016 0 025 N 1 460 000 0 025 N 472 420 000 0 020 N 1024 461 010 0 025 N 1536 489 000 0 020 N 1792 489 000 IMT 2000 Band Uplink MS reverse link 0 N 1199 1920 000 0 050...

Page 523: ...472 N 871 1536 N 1715 0 025 N 1 450 000 0 025 N 472 410 000 0 025 N 1536 479 000 Downlink BS forward link Downlink BS forward link Downlink BS forward link 1 N 400 472 N 871 1536 N 1715 0 025 N 1 460...

Page 524: ...1710 19950 19950 20399 5 869 2400 2400 2649 824 20400 20400 20649 6 875 2650 2650 2749 830 20650 20650 20749 7 2620 2750 2750 3449 2500 20750 20750 20449 8 925 3450 3450 3799 880 21450 21450 21799 9 1...

Page 525: ...ink and downlink is designated by the E UTRA Absolute Radio Frequency Channel Number EARFCN in the range 0 65535 The relation between EARFCN and the carrier frequency in MHz for the downlink is given...

Page 526: ...TDD Option No TX RX frequency separation is required as Time Division Duplex TDD is employed Each subframe consists of 7 main timeslots where all main timeslots at least the first one before the singl...

Page 527: ...can also set a frequency reference and offset This menu is greyed out when on E6630A Radio band settings for GSM cdma2000 and so on most of which are not actually supported in E6630A which has three n...

Page 528: ...numbers to set frequency automatically You will need to set the frequency manually Key Path Source Frequency Radio Setup Radio Standard Initial S W Revision A 05 00 GSM EDGE Sets GSM EDGE as the radi...

Page 529: ...PCS 1900 Selects PCS 1900 as the active channel band Key Path Source Frequency Radio Setup Radio Standard GSM EDGE Example SOUR FREQ CHAN BAND PCS1900 Initial S W Revision A 05 00 GSM 450 Selects GSM...

Page 530: ...0 as the active channel band Key Path Source Frequency Radio Setup Radio Standard GSM EDGE Example SOUR FREQ CHAN BAND T GSM810 Initial S W Revision A 05 00 WCDMA Sets WCDMA as the radio standard for...

Page 531: ...l band Key Path Source Frequency Radio Setup Radio Standard WCDMA Example SOUR FREQ CHAN BAND BANDIV Initial S W Revision A 05 00 Band V Selects Band V as the active channel band Key Path Source Frequ...

Page 532: ...nel band Key Path Source Frequency Radio Setup Radio Standard WCDMA Example SOUR FREQ CHAN BAND BANDIX Initial S W Revision A 05 00 Band X Selects Band X as the active channel band Key Path Source Fre...

Page 533: ...requency Radio Setup Radio Standard WCDMA Example SOUR FREQ CHAN BAND BANDXIV Initial S W Revision A 05 00 CDMA 2000 1xEVDO Sets CDMA 2000 1XEVDO as the radio standard for use and accesses the CDMA 20...

Page 534: ...nd Key Path Source Frequency Radio Setup Radio Standard CDMA 2000 1xEVDO Example SOUR FREQ CHAN BAND KOREAN Initial S W Revision A 05 00 NMT 450 Selects NMT 450 as the active channel band Key Path Sou...

Page 535: ...ath Source Frequency Radio Setup Radio Standard CDMA 2000 1xEVDO Example SOUR FREQ CHAN BAND PAMR400 Initial S W Revision A 05 00 800 PAMR Selects 800 PAMR as the active channel band Key Path Source F...

Page 536: ...tandard CDMA 2000 1xEVDO Example SOUR FREQ CHAN BAND US2DOT5G Initial S W Revision A 05 00 700 Public Safety Selects 700 Public Safety as the active channel band Key Path Source Frequency Radio Setup...

Page 537: ...Standard LTE Example SOUR FREQ CHAN BAND BAND2 Initial S W Revision A 09 50 BAND 3 Selects BAND 3 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE Example SOU...

Page 538: ...LTE Example SOUR FREQ CHAN BAND BAND7 Initial S W Revision A 09 50 BAND 8 Selects BAND 8 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE Example SOUR FREQ CHA...

Page 539: ...TE Example SOUR FREQ CHAN BAND BAND12 Initial S W Revision A 09 50 BAND 13 Selects BAND 13 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE Example SOUR FREQ C...

Page 540: ...TE Example SOUR FREQ CHAN BAND BAND19 Initial S W Revision A 09 50 BAND 20 Selects BAND 20 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE Example SOUR FREQ C...

Page 541: ...TE Example SOUR FREQ CHAN BAND BAND26 Initial S W Revision A 12 53 BAND 27 Selects BAND 27 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE Example SOUR FREQ C...

Page 542: ...BAND33 Initial S W Revision A 11 50 BAND 34 Selects BAND 34 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE TDD Example SOUR FREQ CHAN BAND BAND34 Initial S...

Page 543: ...BAND 39 Selects BAND 39 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE TDD Example SOUR FREQ CHAN BAND BAND39 Initial S W Revision A 11 50 BAND 40 Selects B...

Page 544: ...e band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE TDD Example SOUR FREQ CHAN BAND BAND44 Initial S W Revision A 14 00 TDSCDMA Sets TDSCDMA as the radio standard for...

Page 545: ...BAND BANDD Initial S W Revision A 11 50 BAND E Selects BAND E as the band for the current step Key Path Source Frequency Radio Setup Radio Standard TDSCDMA Example SOUR FREQ CHAN BAND BANDE Initial S...

Page 546: ...to 0 00 Hz All subsequent frequencies entered under Source Frequency Frequency are interpreted as being relative to this reference frequency When you use a frequency reference the signal generator out...

Page 547: ...e Frequency Frequency and set as the reference frequency entered frequency equals a new value entered under Source Frequency Frequency For more information on Reference Frequency refer to Set Referenc...

Page 548: ...the value entered and the RF output frequency will be equal to the value entered minus the offset value as follows Output frequency entered frequency offset frequency Displayed frequency output freque...

Page 549: ...er list sequencer mode and even if ARB state is On the ARB file will not be played Setting Sequencer on page 597Sequencer to Off will make source leave list sequencer mode and this setting will take e...

Page 550: ...is No if you attempt to play a waveform sequence but not all the required waveform segments are contained in the ARB playback memory the application will attempt to load the required segments from eit...

Page 551: ...COPY command Key Path Source Modulation Setup ARB Select Waveform Segments on Hard Disk Remote Command SOURce RADio ARB LOAD string Example SOUR RAD ARB LOAD D VARB testwaveform bin or SOUR RAD ARB L...

Page 552: ...icient free ARB memory to load all the waveforms when the ARB memory is full the copy ceases and an error is generated If you specify a directory over SCPI but the directory does not exist an error is...

Page 553: ...zer mode and Include Source is Yes an attempt to delete a file from ARB memory is rejected with an error When Include Source is No and you specify a file that does not exist within ARB memory an error...

Page 554: ...ing waveform segment may not keep phase continuity during the ARB memory operation The waveform will be replayed after the ARB operation is finished Initial S W Revision A 05 00 Query ARB Memory File...

Page 555: ...eader of the waveform file changing that sample rate is not recommended as it may cause problems with burst timing Dependencies When a new waveform is selected for playback the settings contained with...

Page 556: ...AS FREQ OFFS 0 00 Hz Dependencies When a new waveform is selected for playback the settings contained within the associated waveform header file are applied to the ARB The baseband frequency offset is...

Page 557: ...er relationship defined by Power Control Mode on page 558 Power Control Mode and other noise settings Preset Off Range On Off Initial S W Revision A 16 00 Carrier To Noise Ratio Allows you to specify...

Page 558: ...width Allows you to specify the flat noise bandwidth of the real time noise for an ARB waveform Key Path Source Modulation Setup ARB ARB Setup Real Time AWGN Setup Remote Command SOURce RADio ARB NOIS...

Page 559: ...t by the total power C N and the rest of the Noise settings The carrier power and total noise power change as any noise parameter is adjusted to keep the total power and the C N at their last specifie...

Page 560: ...ouplings Set to this value will make Channel Noise Power Channel Noise Power button visible while Total Noise Power Total Noise Power and Carrier Power Carrier Power buttons invisible from menu Select...

Page 561: ...nd to triggers Key Path Source Modulation Setup ARB Trigger Type Continuous Example SOUR RAD ARB TRIG TYPE CONT FREE Initial S W Revision A 05 00 Trigger Run Sets Trigger and Run as the trigger respon...

Page 562: ...rt on Trigger Initial S W Revision A 05 00 No Retrigger Selects No Retrigger as the trigger response for single trigger type No Retrigger sets the waveform generator to play a waveform sequence or seg...

Page 563: ...the repetition count for the waveform segment within the waveform sequence For example if a waveform segment has a repetition count of 10 and you select single segment advance triggering mode the wav...

Page 564: ...h Source Modulation Setup ARB Remote Command SOURce RADio ARB TRIGger SOURce KEY BUS EXTernal2 SOURce RADio ARB TRIGger SOURce Example SOUR RAD ARB TRIGger KEY Dependencies This key is grayed out if t...

Page 565: ...tup ARB Notes No remote command SCPIfront panel only Initial S W Revision A 05 00 Waveform Sequences Allows access to the waveform sequence sub menus Pressing this key changes the central view area to...

Page 566: ...Revision A 05 00 Insert Waveform Inserts the currently highlighted waveform to the end of the waveform sequence Pressing this key also returns you to the menus for creating or editing a sequence and...

Page 567: ...ng is complete string specifies the path name of the file to load from the HDD into ARB memory It could be a full path filename or NVWFM MSUS colon filename When in Sequence Analyzer mode and Include...

Page 568: ...Revision A 05 00 Change Directory Allows you to change the currently selected directory on the hard disk Pressing this key opens a standard windows change directory dialog allowing you to select the n...

Page 569: ...er If you attempt to delete a file which is being used by the list sequencer an error is generated When sequencer state is On even if ARB state is On the selected waveform will not be played In this c...

Page 570: ...rior to A 09 00 Load Segment To ARB Memory This key functions the same as Load Segment To ARB Memory on page 622 Key Path Source Modulation Setup ARB Waveform Sequences Build New Sequence Insert New W...

Page 571: ...Segment in ARB Memory Initial S W Revision Prior to A 09 00 Delete All From ARB Memory This key functions the same as Delete All From ARB Memory on page 625 Key Path Source Modulation Setup ARB Wavef...

Page 572: ...nts within the sequence but not for others Key Path Source Modulation Setup ARB Waveform Sequences Build New Sequence Edit Selected Waveform Notes No remote command front panel only Preset Enabled Ran...

Page 573: ...t markers from some waveform segments within the sequence but not for others Key Path Source Modulation Setup ARB Waveform Sequences Build New Sequence Edit Selected Waveform Notes No remote command f...

Page 574: ...RADio ARB SEQuence MWAVeform filename waveform1 reps NONE M1 M2 M3 M4 M1M2 M1M3 M1M4 M2M3 M2M4 M3M4 M1M2M3 M1M2M4 M1M3M4 M2M3M4 M1M2M3M4 ALL waveform2 reps NONE M1 M2 M3 M4 M1M2 M1M3 M1M4 M2M3 M2M4 M3...

Page 575: ...to a waveform sequence file Just repeat inserting waveform segments as described above Error Checks for Setup SCPI command If you do not specify a filename or you use an unsupported MSUS that is not N...

Page 576: ...andard windows change directory dialog and allows you to select the new directory of interest Key Path Source Modulation Setup ARB Waveform Sequences Notes No remote command front panel only Initial S...

Page 577: ...rm ADD is provided to be consistent with the style of Keysight signal sources You can use either one of them Since adding a waveform segment to a Multi Pack license causes the license slot to enter th...

Page 578: ...e length this command should be followed by the query OPC which holds off subsequent commands until the loading operating is complete string specifies the path name of the file to load from the HDD in...

Page 579: ...tes file to ARB memory the playing waveform segment may not keep phase continuity during the ARB memory operation The waveform will be replayed after the ARB operation is finished Initial S W Revision...

Page 580: ...Waveform Segment on Hard Drive Initial S W Revision Prior to A 09 00 Load All To ARB Memory This key functions the same as Load All To ARB Memory on page 623 Key Path Source Modulation Setup ARB Wavef...

Page 581: ...ce int string or SYSTem LICense FPACk WAVeform REPLace int string Example SYST LKEY WAV REPL 1 myotherwaveform wfm or SYST LIC WAV REPL 1 myotherwaveform wfm Notes The second SCPI SYSTem LICense FPACk...

Page 582: ...Segment on Hard Drive Initial S W Revision Prior to A 09 00 Default Directory This key functions the same as Default Directory on page 624 Key Path Source Modulation Setup ARB Waveform Utilities Mult...

Page 583: ...provided to be consistent with the style of Keysight signal sources You can use either one of them Waveform slot number int is positive If you attmpt to input a slot number less than or equals 0 an er...

Page 584: ...nt with the style of Keysight signal sources You can use either one of them Initial S W Revision A 05 00 Slot Used Query Remote Command Only Returns the number of license slots used Remote Command SYS...

Page 585: ...SYSTem LKEY WAVeform UID int or SYSTem LICense FPACk WAVeform UID int Example SYST LKEY WAV UID 2 1346752140 or SYST LIC WAV UID 2 1346752140 Notes Waveform slot number int is positive If you attmpt t...

Page 586: ...h during the marker points For a negative marker polarity the marker signal is high during the period of no marker points Key Path Source Modulation Setup ARB Marker Utilities Initial S W Revision A 0...

Page 587: ...ou to set the polarity of marker 3 Key Path Source Modulation Setup ARB Marker Utilities Marker Polarity Remote Command SOURce RADio ARB MPOLarity MARKer3 POSitive NEGative SOURce RADio ARB MPOLarity...

Page 588: ...function blanks the RF when the marker signal goes low The marker polarity determines when the marker signal is high For a positive polarity this is during the marker points For a negative polarity th...

Page 589: ...A 05 00 Marker 2 Sets marker 2 to be used for the pulse RF blanking function Key Path Source Modulation Setup ARB Marker Utilities Marker Routing Pulse RF Blank Example SOUR RAD ARB MDES PULS M2 Initi...

Page 590: ...hold setting is one of the values stored within the header file If the newly selected waveform file has an associated header file the ALC hold setting is updated with the value from the header file Th...

Page 591: ...File Header Information view Key Path Source Modulation Setup ARB Dependencies This key is only available if there is currently a waveform selected for playback If no waveform is selected the key is g...

Page 592: ...ready loaded into the ARB memory MMEM HEAD ID D VARB test wfm query the waveform on the hard disk by absolute path MMEM HEAD ID NVWFM test wfm query the waveform on the hard disk by MSUS Notes SCPI qu...

Page 593: ...xample SOUR AM STAT OFF Preset Off Range On Off Initial S W Revision A 05 00 AM Depth Allows you to set the amplitude modulation depth in percent Key Path Source Modulation Setup AM Remote Command SOU...

Page 594: ...in the previous modulation format being turned off and the generation of an error Key Path Source Modulation Setup FM Remote Command SOURce FM STATe SOURce FM STATe Example SOUR FM STAT OFF Preset Of...

Page 595: ...ion Setup Initial S W Revision A 05 00 PM Enables or disables the phase modulation Turning PM on when another modulation format is already on results in the previous modulation format being turned off...

Page 596: ...lude its own waveform file for playback step duration trigger event and trigger output The complexities involved in configuring the list sequencer do not lend itself to manual configuration hence the...

Page 597: ...ssing this key arms the sequence for single execution Once the sequence is armed the source begins the sequence as soon as the trigger is received If the trigger is set to Free Run the sequence starts...

Page 598: ...moved steps are not reset This means that increasing the number of steps again would allow you to retrieve these steps Dependencies The Step Count parameter is increased or decreased when you insert o...

Page 599: ...el key only If the list already contains the minimum limit of 1 step no operation will be made after pressing this key Initial S W Revision A 05 00 Clear List Allows you to clear the list Clearing the...

Page 600: ...nd will have no effect At any point in the sequence where the list sequencer is paused waiting for a software trigger a pop up dialog is displayed until the trigger event occurs Key Path Source List S...

Page 601: ...g this period of time you do not use the source output signal The following table lists recommended values for appropriate settling times to allow for changes within the source Value Changed Recommend...

Page 602: ...SM RGSM DCS1800 PCS1900 TGSM810 GSM450 GSM480 GSM700 GSM850 BANDI BANDII BANDIII BANDIV BANDV BANDVI BANDVII BANDVIII BANDIX BANDX BANDXI BANDXII BANDXIII BANDXIV BANDXIX USCELL USPCS JAPAN KOREAN NMT...

Page 603: ...A 05 00 P GSM Selects P GSM as the band for the current step Key Path Source List Sequencer List Sequencer Setup Radio Setup Radio Standard GSM EDGE Initial S W Revision A 05 00 E GSM Selects E GSM a...

Page 604: ...ncer List Sequencer Setup Radio Setup Radio Standard GSM EDGE Initial S W Revision A 05 00 GSM 850 Selects GSM 850 as the band for the current step Key Path Source List Sequencer List Sequencer Setup...

Page 605: ...Radio Standard WCDMA Initial S W Revision A 05 00 Band II Selects Band II as the band for the current step Key Path Source List Sequencer List Sequencer Setup Radio Setup Radio Standard WCDMA Initial...

Page 606: ...WCDMA Initial S W Revision A 05 00 Band VIII Selects Band VIII as the band for the current step Key Path Source List Sequencer List Sequencer Setup Radio Setup Radio Standard WCDMA Initial S W Revisio...

Page 607: ...d for the current step Key Path Source List Sequencer List Sequencer Setup Radio Setup Radio Standard WCDMA Initial S W Revision A 05 00 CDMA 2000 1xEVDO Pressing this key once selects CDMA 2000 1xEVD...

Page 608: ...List Sequencer Setup Radio Setup Radio Standard CDMA 2000 1xEVDO Initial S W Revision A 05 00 NMT 450 Selects NMT 450 as the band for the current step Key Path Source List Sequencer List Sequencer Set...

Page 609: ...List Sequencer Setup Radio Setup Radio Standard CDMA 2000 1xEVDO Initial S W Revision A 05 00 2 5GHz IMT EXT Selects 2 5 GHz IMT EXT as the band for the current step Key Path Source List Sequencer Li...

Page 610: ...Standard CDMA 2000 1xEVDO Initial S W Revision A 05 00 LTE Pressing this key once selects LTE FDD as the radio standard and the current LTE FDD band as the active channel band Pressing this key again...

Page 611: ...Sequencer List Sequencer Setup Radio Setup Radio Standard LTE Initial S W Revision A 09 50 BAND 6 Selects BAND 6 as the band for the current step Key Path Source List Sequencer List Sequencer Setup R...

Page 612: ...Sequencer List Sequencer Setup Radio Setup Radio Standard LTE Initial S W Revision A 09 50 BAND 12 Selects BAND 12 as the band for the current step Key Path Source List Sequencer List Sequencer Setup...

Page 613: ...Sequencer List Sequencer Setup Radio Setup Radio Standard LTE Initial S W Revision A 09 50 BAND 20 Selects BAND 20 as the band for the current step Key Path Source List Sequencer List Sequencer Setup...

Page 614: ...List Sequencer Setup Radio Setup Radio Standard LTE Initial S W Revision A 14 00 BAND 28 Selects BAND 28 as the band for the current step Key Path Source List Sequencer List Sequencer Setup Radio Set...

Page 615: ...BAND 35 Selects BAND 35 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE TDD Example SOUR FREQ CHAN BAND BAND35 Initial S W Revision A 11 50 BAND 36 Selects B...

Page 616: ...BAND 40 Selects BAND 40 as the band for the current step Key Path Source Frequency Radio Setup Radio Standard LTE TDD Example SOUR FREQ CHAN BAND BAND40 Initial S W Revision A 11 50 BAND 41 Selects B...

Page 617: ...o standard for use and accesses the TDSCDMA specific channel band sub menus Key Path Source Frequency Radio Setup Radio Standard Initial S W Revision A 11 50 BAND A Selects BAND A as the band for the...

Page 618: ...CDMA Example SOUR FREQ CHAN BAND BANDF Initial S W Revision A 11 50 Radio Band Link Allows you to specify the radio band link direction for the steps within the list sequence The link is used in conju...

Page 619: ...n it s channel number Couplings The channel number is coupled to the step frequency value When the step frequency value is changed the channel number will increase or decrease to match the new step fr...

Page 620: ...es for the RF power do not change dependant on the current amplitude correction setting Instead if the combination of RF power amplitude correction is higher or lower than the source output range the...

Page 621: ...m string SOURce LIST STEP 1 2 3 1000 SETup WAVeform Example SOUR LIST STEP2 SET WAV CW SOUR LIST STEP2 SET WAV Notes SCPI is supported after A 09 40 Remote Command Notes String type takes Off CW Cont...

Page 622: ...rted after A 09 40 Initial S W Revision A 05 00 Segments on Hard Disk Allows you access to the sub menus for loading waveform segments from the hard disk into ARB memory The default directory is D var...

Page 623: ...load a waveform file but the file contains less than 500 IQ sampes an error is generated If you try to load a Signal Studio waveform wfm which contains invalid waveform header an error is generated If...

Page 624: ...on for waveform segments that are required to be loaded into ARB memory for playback of a waveform sequence or a list sequence Key Path Source Modulation Setup ARB Select Waveform Segments on Hard Dis...

Page 625: ...If the ARB is ON and you load a file to ARB memory or delete a file from ARB memory the playing waveform segment may not keep phase continuity during the ARB memory operation The waveform will be rep...

Page 626: ...ncer List Sequencer Setup Waveform Segment on Hard Drive Initial S W Revision Prior to A 09 00 Change Directory This key functions the same as Change Directory on page 624 Key Path Source List Sequenc...

Page 627: ...ion cannot be set to a play count Key Path Source List Sequencer List Sequencer Setup Remote Command SOURce LIST STEP 1 2 3 1000 SETup DURation TYPE TIME COUNt CONTinuous CABort SOURce LIST STEP 1 2 3...

Page 628: ...p Validation Key Path Source List Sequencer List Sequencer Setup Step Duration Time Remote Command SOURce LIST STEP 1 2 3 1000 SETup DURation TCOunt double SOURce LIST STEP 1 2 3 1000 SETup DURation T...

Page 629: ...the current step to be played continuously until the next step starts The waveform will always play completely before transitioning to the next step Key Path Source List Sequencer List Sequencer Setup...

Page 630: ...items in each step the following is a list of the items in the order they must appear in the remote command 1 Step Trigger enum specifies the input trigger for the step For details of the valid types...

Page 631: ...e of subopcode values is 1 to 1000 and the value you enter is determined by the number of steps you have configured For details see Number of Steps on page 598 If you attempt to remotely set or query...

Page 632: ...tion Time on page 601 If input parameter number exceeds the step number defined by Number of Steps on page 598Number of Steps then generate error and only those parametes whose index number falls in n...

Page 633: ...GSM480 GSM700 GSM850 BANDI BANDII BANDIII BANDI V BANDV BANDVI BANDVII BANDVIII BANDIX BANDX BANDXI BANDXII BANDXIII BANDXIV BANDXIX USCELL USPCS JAPAN KO REAN NMT IMT2K UPPER SECOND PAMR400 PAMR800 I...

Page 634: ...exceeds the step number defined by Number of Steps on page 598Number of Steps then generate error and only those parametes whose index number falls in number of steps will be updated Remote Command No...

Page 635: ...ameter list Remote Command Only This SCPI command is to configure Power parameter array of the whole List Sequencer at one time The number of array is same as step number defined in Number of Steps on...

Page 636: ...9 40 Step Configuration of Step Duration parameter list Remote Command Only This SCPI command is to configure Step Duration parameter array of the whole List Sequencer at one time The number of array...

Page 637: ...ex number falls in number of steps will be updated If current Step Duration on page 627 is Continuous then generate error 221 Settings conflict Cannot accept time or count input when step duration typ...

Page 638: ...ed between different sequence steps Key Path Source List Sequencer Remote Command SOURce LIST TRIGgerout TYPe BEGinningofstep DATamarker Example SOUR LIST TRIG TYP BEG SOUR LIST TRIG TYP Notes SCPI is...

Page 639: ...arker in the whole source sequence Key Path Source List Sequencer Trigger Type DataMarker Example SOUR LIST TRIG TYPE MARK M1 Notes SCPI is supported after A 14 00 This an alias SCPI of SOURce LIST TR...

Page 640: ...Put TYPE MARKer M4 Recommend to use SOURce LIST TRIGger OUTPut TYPE MARKer M4 Initial S W Revision A 14 00 Manual Trigger Now Pressing this key provides a software trigger event to the list sequencer...

Page 641: ...his command can be blocked until event status IsSourceSweeping happens and then returns Doing so can help user s script query armed status only once during the time interval of the initiation As an an...

Page 642: ...6 List Sequence Measurements System System See System on page 152 642 Sequence Analyzer User s Programmer s Reference...

Page 643: ...TRACe MAXHold STATe Example DISP LSEQ VIEW WIND TRAC MAXH ON DISP LSEQ VIEW WIND TRAC MAXH Notes You must be in the Sequnece Analyzser mode to use this command Use INSTrument SELect to set the mode P...

Page 644: ...Notes You must be in the Sequnece Analyzser mode to use this command Use INSTrument SELect to set the mode Preset OFF State Saved Saved in instrument state Range ON OFF 1 0 Initial S W Revision A 05...

Page 645: ...itching into each mode User Preset recalls mode state which can now include data like traces whereas on ESA and PSA User Preset did not affect data Initial S W Revision Prior to A 02 00 User Preset Us...

Page 646: ...n the instrument is secured all of the user preset files are converted back to their default user preset files The User Preset function does the following Aborts the currently running measurement Swit...

Page 647: ...remote command This same state is also saved by the Save State function Key Path User Preset Remote Command SYSTem PRESet USER SAVE Example SYST PRES USER SAVE Notes SYST PRES SAVE creates the same f...

Page 648: ...urns on and off various parts of the display annotation The annotation is divided up into four categories 1 Meas Bar This is the measurement bar at the top of the screen It does not include the settin...

Page 649: ...e area formerly occupied by the Measurement Bar Key Path View Display Display Annotation Remote Command DISPlay ANNotation MBAR STATe OFF ON 0 1 DISPlay ANNotation MBAR STATe Example DISP ANN MBAR OFF...

Page 650: ...ay Annotation Remote Command DISPlay ANNotation SCReen STATe OFF ON 0 1 DISPlay ANNotation SCReen STATe Example DISP ANN SCR OFF Dependencies Grayed out and forced to OFF when System Display Settings...

Page 651: ...reset On This should remain Off through a Preset when System DisplaySettings Annotation is set to Off State Saved Saved in instrument state Initial S W Revision Prior to A 02 00 Title Displays menu ke...

Page 652: ...e is not used DISP ACP ANN TITL DATA This Is My Title This example is for Measurements other than Swept SA Both set the title to This Is My Title Notes Pressing this key cancels any active function Wh...

Page 653: ...aults or Restore System Defaults under System Key Path View Display Display Initial S W Revision Prior to A 02 00 Annotation Local Settings This is a Mode Global override of the meas local annotation...

Page 654: ...part of Preset but is reset by Restore Misc Defaults or Restore System Defaults All and survives subsequent running of the modes Readback 3D Color 3D Mono Flat Color Flat Mono Backwards Compatibility...

Page 655: ...ly black is used no colors not even gray and no fill Key Path Save Screen Image Themes Example MMEM STOR SCR THEM FMON Readback Flat Mono Initial S W Revision Prior to A 02 00 View Selection Accesses...

Page 656: ...List Sequence Measurements View Display State Saved Saved in instrument state Range RESult RFENvelope Initial S W Revision A 05 00 Help Map ID 35264 656 Sequence Analyzer User s Programmer s Referenc...

Page 657: ...This information is subject to change without notice Keysight Technologies 2014 2015 Edition 1 July 2015 V9065 90003 www keysight com...

Reviews: