2 Programming the Test Set
STATus Subsystem
Min
0
Max
32767
Status Bits/OPC
dependencies
Sequential command
Initial S/W Revision
Prior to A.02.00
Questionable Temperature Positive Transition
This command determines which bits in the Questionable Temperature Condition register will set the
corresponding bit in the Questionable Temperature Event register when the condition register bit has a
positive transition (0 to 1). The variable <integer> is the sum of the decimal values of the bits that you want
to enable.
Mode
All
Remote Command
:STATus:QUEStionable:TEMPerature:PTRansition <integer>
:STATus:QUEStionable:TEMPerature:PTRansition?
Example
STAT:QUES:TEMP:PTR 1 Reference Oscillator Oven became cold will be reported to the
Temperature Summary of the Status Questionable register.
Preset
32767
Min
0
Max
32767
Status Bits/OPC
dependencies
Sequential command
Initial S/W Revision
Prior to A.02.00
84
Sequence Analyzer User's & Programmer's Reference